Document
DC-DC Converters
VI-200 VE-200
®S
C US C NRTL US
50 to 200 Watts
Features & Benefits
• Isolated output • Up to 50 W/in3 • cURus, cTÜVus • Up to 90% efficiency • Size: 4.6” x 2.4” x 0.5” (116,8 x 61,0 x 12,7mm) • Remote sense and current limit • OVP, thermal shutdown • Logic disable • Wide range output adjust • Compatible power booster modules • ZCS power architecture • Low noise FM control • CE Marked
• RoHS compliant (VE-200)
Product Highlights
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of “zero-current-switching” component-level DC-DC converters.
Operating at frequencies up to 2MHz, VI-200 family converters offer exceptional power density, efficiency, noise performance, reliability and ease of use. Booster modules (VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output requirements. One or more boosters may be used to create synchronous arrays capable of supplying several kilowatts of output power.
The flexibility of Vicor’s power components is also available in half-size, half-power VI-J00 MiniMods.
Part Numbering
VI — 2 6 1 — C W
Family Series
Input
VI = Non-RoHS 2 = 200
0 = 12 V N = 48 V
VE = RoHS
B = Booster V = 24 V 4 = 72 V
1 = 24 V T = 110 V
No te: F or add itio nal pac kag ing op tion s, ple ase se e pa ge 5.
W = 24 V 2 = 36 V 3 = 48 V
5 = 150 V 6 = 300 V 7 = 150/300 V
Z = 2 V Y = 3.3 V 0 = 5 V X = 5.2 V W = 5.5 V V = 5.8 V T = 6.5 V R = 7.5 V
Output
Grade
Power
M = 10 V K = 40 V E = –10 to 85°C
≥ 5V
< 5V
1 = 12 V 4 = 48 V C = –25 to 85°C U = 200W U = 40A
P = 13.8 V H = 52 V I = – 40 to 85°C V = 150W V = 30A
2 = 15 V F = 72 V M = –55 to 85°C W = 100W W = 20A
N = 18.5 V D = 85 V
X = 75W X = 15A
3 = 24 V B = 95 V
Y = 50W Y = 10A
L = 28 V
J = 36 V
VI-200 DC-DC Converters Page 1 of 6
Rev 3.7 09/2016
vicorpower.com 800 927.9474
VI-200, VE-200
Maximum Power Available for VI-2xx-xx[a]
VIN Designators
2 3.3 5 5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36 40 48 52 72 85 95
Input
Output
Voltage Nom. (Range)
Low Line 75% Max Power
Transient[b]
VOUT Designators Z Y 0 XWV T RM1 P 2 N 3 L J K 4 H F D B
12 (10 – 20)
n/a
22
0 XXXXXXXXXXXXXXXXXXXXXX
24 (10 – 36)
n/a
n/a
V -- X Y Y Y Y Y X X X X X X X X X X X -- -- -- --
24 (21 – 32)
18
36
1 UUUUUUVVUUUUUUUUUUUUUU
24 (18 – 36)
n/a
n/a
W V V V V V V WW V V V V V V V V V V V V V V
36 (21 – 56)
18
60
2 W V W W W W W W W W W W W W W W W W W -- -- --
48 (42 – 60)
36
72
3 UUUUUUUUUUUUUUUUUUUUUU
48 (36 – 76)
n/a
n/a
N UUUUUUUUUUUUUUUUUUUUUU
72 (55 – 100)
45
110
4 v UUUUUVVUUUUUUUUUUUUUU
110 (66 – 160) n/a n/a T V V V V V V W W V V V V V V V V V V V V -- --
150 (100 – 200) 85[c]
215
5 UUVVVVVVUUUUUUUUUUUUUU
150 (100 – 375) n/a n/a 7 W W Y Y Y Y W W W W W W W W W W W W W -- -- --
300 (200 – 400) 170[d]
425
6 UUUUUUVVUUUUUUUUUUUUUU
[a] For additional output power, “booster” modules are available. (VI-Bxx-xx). [b] Transient voltage for 1 second. [c] 15 VOUT, 200W models are limited to 90VDC. [d] 15 VOUT, 200W models are limited to 185VDC.
Converter Specifications (typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter
Inrush charge Input reflected ripple current – pp
Input ripple rejection
No load power dissipation
VI-200 E-Grade
Min Typ Max
120 x 10-6
10%
( )25+20 Log
VIN VOUT
1.35 2
VI-200 C-, I-, M-Grade
Min Typ
Max
120 x 10-6
200 x 10-6
10%
( )30+20 Log
VIN VOUT
( )20+20 Log
VIN VOUT
1.35 2
Units Coulombs
IIN dB dB Watts
Test Conditions
Nominal line
Nominal line, full load
120Hz, nominal line
2400Hz, nominal line
VI-200 DC-DC Converters Page 2 of 6
Rev 3.7 09/2016
vicorpower.com 800 927.9474
VI-200, VE-200
Converter Specifications (Cont.)
OUTPUT CHARACTERISTICS
VI-200 E-Grade
VI-200 C-, I-, M-Grade
Parameter
Min
Typ
Max
Min
Typ
Max
Units
Test Conditions
Setpoint accuracy
1% 2%
0.5%
1% VNOM
Load/line regulation
0.5%
0.05%
0.2%
VNOM
LL to HL, 10% to Full Load
Load/line regulation
1%
0.2%
0.5%
VNOM
LL to HL, No Load to 10%
Output temperature drift
0.02
0.01
0.02
% / °C
Over rated temp.
Long term drift
0.02
0.02 %/1K hours
Output ripple – pp: 2V, 3.3V
20MHz 150 60 100 mV bandwidth
5V
5%
2%
3%
VNOM
20MHz bandwidth
10 – 95V Trim range[a]
50%
3% 110%
50%
0.75%
1.5% 110%
VNOM VNOM
20MHz bandwidth
Total remote sense compensation
0.5
0.5
Volts
0.25V max. neg. leg
OVP set point Current limit
105%
125%[b]
135%
115% 105%
125%[b]
135% 125%
VNOM IFULL LOAD
Recycle power
Automatic restart
Short circuit current[c]
20%
140%
20%
130%
IFULL LOAD
Automatic restart
[a] 10V to 15V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range. 3.3V output trim range 2.20 to 3.63V, 95V output .