NCS37000
Ground Fault Circuit
Interrupter (GFCI)
Description
The NCS37000 is a fully UL943 compliant signal processor f...
NCS37000
Ground Fault Circuit
Interrupter (GFCI)
Description
The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO
regulators), differential fault, and grounded-neutral detection circuits. Proprietary impedance measurement and signal processing techniques are used to minimize the number of external components and improve performance. The device also includes a specialized DSP controller that offers best in class immunity to nuisance loads without the need for external analog filters.
Features
6.0 – 12 Volt Operation (120 − 480 V AC mains with the appropriate
series impedance)
−40 to 85°C Very Low Power Consumption: <5 mW @ 5 V 16 Pin QFN Package or 20 Pin TSSOP Package Single Current Transformer (CT) Detection of both Differential and
Grounded−Neutral Faults
Self Syncing Internal Oscillator Adjusts to AC Mains Frequency to
Guarantee Full Resolution on ...