Grow-FlexTM Feed System
HS10 Feed Sensor
Specifications:
Operating Voltage: 90-250 VAC Frequency: 50-60 Hz Relay Contact Maximum Current Load: 5A Resistive and 2A Inductive (Motors and Relays) Sensitivity: 0-9/16” (Factory Setting is for ¼”) Time Delay Range: 0-4 Hours (Factory Setting is for 30 seconds) Ambient Operating Temperature: -4°F-+158°F Cord: Length= 5’ 18-5 SJTW
These instructions are guidelines for new GrowerSelect installation in four (4) wire Sensor control units. In all cases, the OEM (Original Equipment Manufacturer) wiring instructions should be followed if possible.
It is in no way to be used to violate or supersede local, state and national wiring codes. All wiring sizes and fuse capacities are to be sized according to national electrical code specifications or other applicable regulations.
For the purpose of installation:
• NC (Normally Closed) is defined as contacts closed (runs) with power supply connected to sensor and no product in contact with sensor.