pressure transmitter. MBS3000 Datasheet

MBS3000 transmitter. Datasheet pdf. Equivalent

Part MBS3000
Description pressure transmitter
Feature Data sheet MBS 3000 pressure transmitter for industrial applications Introduction • Designed for .
Manufacture Danfoss
Datasheet
Download MBS3000 Datasheet

Data sheet MBS 3000 pressure transmitter for industrial app MBS3000 Datasheet
Recommendation Recommendation Datasheet MBS3000 Datasheet




MBS3000
Data sheet
MBS 3000 pressure transmitter for industrial applications
Introduction
Designed for use in severe industrial
environments
Enslosure and wetted parts of acid-
resistant stainless steel (AISI 316L)
All standard output signals: 4-20 mA, 0-5 V,
1-5 V, 1-6 V, 0-10 V
A wide range of pressure and electrical
connections
Temperature compensated and laser
calibrated
Typical applications:
- Pumps
- Compressors
- Pneumatics
- Water treatment
Dimensions
Ordering
Type code
Page 4
8
AMP Superseal
1.5 series (male)
25
7
1
3
AMP Econoseal
J series (male)
IEC 947-5-2 ISO 15170-A1-3.2-Sn DIN 43650, Pg 9 2 m screened cable
M12×1, 4-pin
(Bayonet plug)
u
Ordering
1/4 - 18 NPT
Type code
page 4
AC04
½ - 14 NPT
AC08
DIN 3852-E-G1/4
Gasket:
DIN 3869-14
GB04
G 1/4 A
(EN 837)
AB04
©Danfoss A/S 11-2002
G 3/8A
(EN 837)
AB06
G ½A
(EN 837)
AB08
DKACT.PD.P20.K2.02
520B1374



MBS3000
Data sheet
Technical data
2
Pressure transmitter for industrial application MBS 3000
Main specifications
Pressure connections
Measuring ranges
Output signals
Electrical connections
[bar]
see page 1
0-1 0-1.6 0-2.5 0-4 0-6 0-10 0-16
0-25 0-40 0-60 0-100 0-160 0-250 0-400 0-600
4-20 mA
0-5 V 1-5 V 1-6 V
see page 3
0-10 V
Performance (IEC 770)
Accuracy
Non-linearity (best fit straight line)
Hysteresis and repeatability
Thermal zero point shift
Thermal sensitivity (span) shift
Response time
Overload pressure
Burst pressure
Durability, P: 10-90% FS
±0.5% FS (typ.)
±1% FS (max.)
±0.5% FS
≤ ±0.1% FS
≤ ±0.1% FS/10K (typ.)
±0.2% FS/10K (max.)
≤ ±0.1% FS/10K (typ.)
±0.2% FS/10K (max.)
< 4 ms
6 × FS (max. 1500 bar)
6 × FS (max. 2000 bar)
>10×106 cycles
Electrical specifications
Supply voltage [UB], polarity protected
Supply - current consumption
Supply voltage dependency
Current limitation
(linear output up to 1.5x nom. range)
Output impedance
Load [RL] (load connected to 0V)
Nom. output signal (short-circuit protected)
4 20 mA
0-5, 1-5, 1-6 V d.c. 0-10 V d.c.
9 32 V d.c.
9 30 V d.c.
15 30 V d.c.
-
5 mA
8 mA
≤ ±0.05% FS/10 V
34 mA (typ.)
-
-
RL (UB-9V)/0.02
25
RL 10 k
RL 15 k
Environmental conditions
Medium temperature range
Ambient temperature range (depending on electrical connection)
40 +85°C
see page 3
Compensated temperature range
0 +80°C
Transport temperature range
50 +85°C
EMC - Emission
EN 61000-6-3
Electrostatic discharge Air mode
8 kV
Contact mode 4 kV
EN 61000-6-2
EN 61000-6-2
EMC - Immunity
RF
Transient
Insulation resistance
field
conducted
burst
surge
10 V/m, 26 MHz - 1 GHz
10 Vrms, 150 kHz - 30 MHz
4 kV (CM),Clamp
1 kV (CM,DM), Rg = 42
EN 61000-6-2
EN 61000-6-2
EN 61000-6-2
EN 61000-6-2
> 100 Mat 100 V d.c.
Mains frequency test
500 V, 50 Hz
SEN 361503
Vibration stability Sinusoidal
15.9 mm-pp, 5Hz-25Hz
20 g, 25 Hz - 2 kHz
IEC 60068-2-6
Shock resistance
Random
Shock
Free fall
7.5 g rms, 5 Hz - 1 kHz
500 g / 1 ms
IEC 60068-2-34, IEC 60068-2-36
IEC 60068-2-27
IEC 60068-2-32
Enclosure (depending on electrical connection)
see page 3
Mechanical characteristics
Materials
Wetted parts
Enclosure
Electrical connections
Weight (depending on pressure connection and electrical connection)
DIN 17440-1.4404 (AISI 316 L)
DIN 17440-1.4404 (AISI 316 L)
see page 3
0.2-0.3 kg
DKACT.PD.P20.K2.02
© Danfoss 11-2002





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)