Biomonitoring Sensor. NJL5510R Datasheet

NJL5510R Sensor. Datasheet pdf. Equivalent


New Japan Radio NJL5510R
NJL5510R
Biomonitoring Sensor with Red & IR LED
FEATURES
Peak wavelength : P 660nm (Red), 940nm (Infrared)
Miniature, thin package: 2.4 X 3.75 X 0.8mm
Pb free solder re-flowing permitted: 260C, 2 times
Pb free, Halogen free
Conformity to RoHS directive
APPLICATION
Bio monitor as SpO2, pulse rate of Wearable Devices
(Smart watch, Fitness Tracker etc.)
Mobile Devices
GENERAL DESCRIPTION
NJL5510R is the compact surface mount type
photo sensor, which is built in a RED LED,
Infrared LED and a high sensitive photo diode.
NJL5510R is a sensor for SpO2, pulse rate
(heart rate) measurement which shows one of
fitness application that targeted the fitness tracker
like Smart watch/Band/Bracelet.
EQUIVALENT CIRCUIT BLOCK DIAGRAM
1. LRK
2. LRA
3. PA
6. LIRK
5. LIRA
4. PK
PIN CONFIGURATION
PIN NO.
1
2
3
4
5
6
SYMBOL
LRK
LRA
PA
PK
LIRA
LIRK
DESCRIPTION
Cathode for RED LED
Anode for RED LED
Anode for PD
Cathode for PD
Anode for IR LED
Cathode for IR LED
(Top View)
1. LRK
2. LRA
3. PA
6. LIRK
5. LIRA
4. PK
ORDERING INFORMATION
PART NUMBER
PACKAGE
OUTLINE
NJL5510R
COBP
RoHS
HALOGEN- TERMINAL
FREE
FINISH
Au
MARKING
No marking
WEIGHT
(mg)
12
MOQ(pcs)
3,000
Ver.1 http://www.njr.com/ - 1 -


NJL5510R Datasheet
Recommendation NJL5510R Datasheet
Part NJL5510R
Description Biomonitoring Sensor
Feature NJL5510R; NJL5510R Biomonitoring Sensor with Red & IR LED ■FEATURES ● Peak wavelength : P 660nm (Red), 940n.
Manufacture New Japan Radio
Datasheet
Download NJL5510R Datasheet




New Japan Radio NJL5510R
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
RATINGS
UNIT
Emitter
Forward Current (Continuous) *2
IF RED
50
mA
IF IR 50 mA
Reverse Voltage (Continuous)
VR RED
5
V
Power Dissipation *1
VR IR
PD
5V
65 mW
Detector
Reverse Voltage
VR 35 V
Power Dissipation
PD 20 mW
Coupled
Total Power Dissipation
Ptot 85 mW
Operating Temperature Range
Storage Temperature Range
Reflow Soldering Temperature
Topr
Tstg
Tsol
-20 to +70
-30 to +85
260
°C
°C
°C
*1 Please do not be turned on the LEDs of different wavelength at the same time.
*2 This is current value of each 1pcs LED.
NJL5510R
Ver.1 http://www.njr.com/ - 2 -



New Japan Radio NJL5510R
NJL5510R
ELECTRO-OPTICAL CHARACTERISTICS (Ta=25 °C)
PARAMETER
SYMBOL
TEST CONDITION
MIN. TYP. MAX. UNIT
Emitter
DC Forward Voltage
Pulse Forward Voltage *1
Reverse Current
Peak Wavelength *2
Detector
Dark Current
Forward Voltage
Terminal Capacitance
Peak Wavelength
Coupled
Output Current *3
Operating Dark Current *4
VF RED
VF IR
VFP RED
VFP IR
IR RED
IR IR
P RED
P IR
IF=10mA
IF=10mA
IFP=100mA
IFP=100mA
VR=5V
VR=5V
IF=10mA
IF=10mA
ID VR=10V, Without incident light
VF IF=1mA, Without incident light
Ct VR=0V, f=1MHz
VR=2.5V, f=1MHz
P
IO RED
IO IR
ILD RED
IF=4mA,VR=2.5V,d=2.0mm(*5)
IF=4mA,VR=2.5V,d=2.0mm(*5)
IF=4mA,VR=2.5V,
Without reflective plate
1.9 2.2 V
1.2 1.4 V
2.1
V
1.4
V
— — 10 µA
— — 10 µA
656 660 664 nm
930 940 950 nm
0.1 2 nA
— — 1.2 V
25 pF
12 pF
800 nm
2.5 8 µA
0.6 1.8 µA
20 100 nA
Response Time(Rise/Fall)
ILD IR
tr,tf RED
tr,tf IR
IF=4mA,VR=2.5V,
Without reflective plate
VR=0V,RL=1k
VR=2.5V,RL=1k
VR=0V,RL=1k
VR=2.5V,RL=1k
20 100 nA
400
250
700
400
ns
ns
ns
ns
*1 Pulse duty 10% (Pulse width 200us, Period 20ms)
*2 This is represented as Emission wavelength range of LED. The emission wavelength verification test has not confirmed
in the manufacturing process.
*3 Please refer to Output Current Test Condition.
*4 ILD may increase according to the periphery situation of the surface mounted condition.
*5 Distance from the package undersurface to the aluminum evaporation surface.
In the Electro-Optical characteristics table, items that are showed only the typical value are not tested in manufacturing
process.
Ver.1 http://www.njr.com/ - 3 -







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)