DC-DC Converter. JWK1024S24 Datasheet

JWK1024S24 Converter. Datasheet pdf. Equivalent

Part JWK1024S24
Description DC-DC Converter
Feature JWK10 Series DC-DC Converter 10 Watts xxx Series• Regulated Single & Dual Output • Wide 4:1 Input .
Manufacture XP Power
Datasheet
Download JWK1024S24 Datasheet

JWK10 Series DC-DC Converter 10 Watts xxx Series• Regulate JWK1024S24 Datasheet
Recommendation Recommendation Datasheet JWK1024S24 Datasheet





JWK1024S24
JWK10 Series
DC-DC Converter
10 Watts
xxx Series• Regulated Single & Dual Output
• Wide 4:1 Input Range
• 1” x 1” Package
• 1500 VDC Isolation
• Operating Temperature -40 °C to +100 °C
• ITE Safety Approvals
• Remote On/Off
• Optional Heatsink
• Six Sided Metal Case
• 3 Year Warranty
Models & Ratings
Input voltage
9-36 V
18-75 V
Output voltage
3.3 V
5V
5.1 V
12 V
15 V
24 V
±5 V
±12V
±15V
3.3 V
5V
5.1 V
12 V
15 V
24 V
±5 V
±12 V
±15 V
Output current
Min Max
330 mA
2.20 A
300 mA
2.00 A
300 mA
2.00 A
125 mA
0.83 A
100 mA
0.66 A
62 mA
0.41 A
±150 mA
±1.00 A
±62 mA
±0.41 A
±50 mA
±0.33 A
330 mA
2.20 A
300 mA
2.00 A
300 mA
2.00 A
125 mA
0.83 A
100 mA
0.66 A
62 mA
0.41 A
±150 mA
±1.00 A
±62 mA
±0.41 A
±50 mA
±0.33 A
Notes
1. Input currents measured at nominal input voltage.
2. Input current is typically 10 mA at nominal input voltage when output is
turned off using remote on/off.
Dimensions:
JWK10:
1.00 x 1.00 x 0.40” (25.4 x 25.4 x 10.16 mm)
Input current(3)
No load
Full load
350 mA
495 mA
505 mA
485 mA
30 mA
475 mA
475 mA
495 mA
475 mA
475 mA
180 mA
250 mA
255 mA
240 mA
20 mA
235 mA
240 mA
250 mA
240 mA
235 mA
Maximum
capacitive load(2)
560 µF
560 µF
560 µF
150 µF
150 µF
68 µF
±220 µF
±100 µF
±100 µF
560 µF
560 µF
560 µF
150 µF
150 µF
68 µF
±220 µF
±100 µF
±100 µF
Efficiency
86%
84%
84%
86%
87%
86%
84%
86%
87%
85%
84%
84%
86%
87%
86%
84%
86%
87%
Model number
JWK1024S3V3
JWK1024S05
JWK1024S5V1
JWK1024S12
JWK1024S15
JWK1024S24
JWK1024D05
JWK1024D12
JWK1024D15
JWK1048S3V3
JWK1048S05
JWK1048S5V1
JWK1048S12
JWK1048S15
JWK1048S24
JWK1048D05
JWK1048D12
JWK1048D15
3. Maximum capacitive load is per output.
4. Add suffix “-HK” for optional heatsink.
Mechanical Details
1.00 (25.4)
0.40 (10.16) 0.40 (10.16)
0.10
(2.54)
3 45
0.24 0.40 ±0.02
(6.0) (10.16 ±0.5)
Bottom View
12
6
ø 0.04
(1.00)
0.20 0.30
(5.08) (7.62)
0.10
(2.54)
Optional Heatsink (-HK)
0.64 (16.3) Max.
0.69 (17.46) Max.
0.77 (19.50) Max.
1.22 (31.0) Max.
Heat-Sink
Thermal Pad
Clamp
Converter
Pin Connections
Pin Single
1 +Vin
2 -Vin
3 +Vout
4 No Pin
5 -Vout
6 Remote On/Off
Dual
+Vin
-Vin
+Vout
Common
-Vout
Remote On/Off
Notes
1. All dimensions are in inches
(mm)
2. Weight: 0.03 lbs (15.0g)
approx.
3. Tolerance: X.XX±0.01 (X.X±0.25)
X.XXX±0.005
(X.XX±0.13)
4. Pin Tolerance: ±0.002 (±0.05)
1 www.xppower.com



JWK1024S24
JWK10 Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Input Filter
Input Surge
Undervoltage Lockout
Remote On/Off
Minimum
Typical
Maximum
9.0 36
18.0 75
Internal Pi type
50
100
ON at >8.5 V, OFF at <9 V
ON at >18 V, OFF at <17 V
ON: Logic high (2.5-50 V) or open circuit
OFF: Logic low (<1.0 V) or short pin 2 to pin 6
Units
VDC
VDC
Notes & Conditions
24 V nominal
48 V nominal
VDC for 1 s
24 V models
48 V models
24 V models
48 V models
Output
Characteristic
Output Voltage
Initial Set Accuracy
Output Voltage Balance
Minimum Load
Line Regulation
Load Regulation
Cross Regulation
Transient Response
Ripple & Noise
Overload Protection
Short Circuit Protection
Maximum Capacitive Load
Temperature Coefficient
Minimum
3.3
Typical
±1.0
3
100
150
Maximum
30
±2.0
±2.0
±1.0
±0.5/±1.0
±5.0
6
0.02
Units
VDC
%
%
A
%
%
%
% deviation
mV pk-pk
%
%/ ˚C
Notes & Conditions
See Models and Ratings table
At full load
For dual output with balanced laods
No minimum load required
From minimum to maximum input at full load
Single / Dual output, from 0 to full load
On dual output models when one load is varied between
25% and 100% and other is fixed at 100%
Recovery within 1% in less than 600 µs for a 25% load
change.
20 MHz bandwidth. Measured using 0.47 µF ceramic
capacitor.
Continuous Trip & Restart (Hiccup mode), with auto recovery
See Models and Ratings table
General
Characteristic
Efficiency
Isolation: Input to Output
Isolation Resistance
Isolation Capacitance
Switching Frequency
Power Density
Mean Time Between Failure
Weight
Minimum
1500/1800
109
Typical
86
450
350
0.03 (15.0)
Maximum
1500
50.8
Units
%
VDC
Ω
pF
kHz
W/in3
kHrs
lb (g)
Notes & Conditions
See Models and Ratings table
60 s/1 s
At 500 VDC
MIL-HDBK-217F, +25 °C GB
Environmental
Characteristic
Operating Temperature
Storage Temperature
Case Temperature
Humidity
Cooling
Minimum
-40
-50
Typical
Maximum
+100
+125
+100
95
Units
°C
°C
°C
%RH
Notes & Conditions
See Derating Curve.
Non-condensing
Natural convection
www.xppower.com
2