OVERLOAD RELAY. 3RU2116-1GC1 Datasheet

3RU2116-1GC1 RELAY. Datasheet pdf. Equivalent


Part 3RU2116-1GC1
Description OVERLOAD RELAY
Feature Data sheet 3RU2116-1GC1 OVERLOAD RELAY 4.5...6.3 A FOR MOTOR PROTECTION SZ S00, CLASS 10, STAND-ALO.
Manufacture Siemens
Datasheet
Download 3RU2116-1GC1 Datasheet


Data sheet 3RU2116-1GC1 OVERLOAD RELAY 4.5...6.3 A FOR MOTO 3RU2116-1GC1 Datasheet
Recommendation Recommendation Datasheet 3RU2116-1GC1 Datasheet




3RU2116-1GC1
Data sheet
3RU2116-1GC1
OVERLOAD RELAY 4.5...6.3 A FOR MOTOR PROTECTION SZ
S00, CLASS 10, STAND-ALONE INSTALLATION MAIN CIRCUIT:
SPRING TERMINAL AUX. CIRCUIT: SPRING TERMINAL MANUAL-
AUTOMATIC-RESET
product brand name
Product designation
General technical data:
Size of overload relay
Size of contactor can be combined company-specific
Active power loss total typical
Insulation voltage with degree of pollution 3 Rated
value
Surge voltage resistance Rated value
Protection class IP
● on the front
● of the terminal
Shock resistance
● acc. to IEC 60068-2-27
Type of assignment
Type of protection
Certificate of suitability relating to ATEX
Protection against electrical shock
Equipment marking acc. to DIN EN 81346-2
SIRIUS
3RU2 thermal overload relay
S00
S00
5.7 W
690 V
6 kV
IP20
IP20
8g / 11 ms
2
Ex e
DMT 98 ATEX G 001
finger-safe
F
3RU2116-1GC1
Page 1/7
15.10.2015
Changes preserved
© Copyright Siemens AG



3RU2116-1GC1
Ambient conditions:
Installation altitude at height above sea level
maximum
Ambient temperature
● during operation
● during storage
● during transport
Temperature compensation
Relative humidity during operation
Main circuit:
Number of poles for main current circuit
Adjustable response value current of the current-
dependent overload release
Operating voltage
● Rated value
● at AC-3 Rated value maximum
Operating frequency Rated value
Operating current Rated value
Auxiliary circuit:
Design of the auxiliary switch
Number of NC contacts
● for auxiliary contacts
— Note
Number of NO contacts
● for auxiliary contacts
— Note
Number of CO contacts
● for auxiliary contacts
Operating current of the auxiliary contacts at AC-15
● at 24 V
● at 110 V
● at 120 V
● at 125 V
● at 230 V
● at 400 V
Operating current of the auxiliary contacts at DC-13
● at 24 V
● at 110 V
● at 125 V
● at 220 V
Protective and monitoring functions:
2 000 m
-40 ... +70 °C
-55 ... +80 °C
-55 ... +80 °C
-40 ... +60 °C
0 ... 90 %
3
4.5 ... 6.3 A
690 V
690 V
50 ... 60 Hz
6.3 A
integrated
1
for contactor disconnection
1
for message "Tripped"
0
3 A
3 A
3 A
3 A
2 A
1 A
2 A
0.22 A
0.22 A
0.11 A
3RU2116-1GC1
Page 2/7
15.10.2015
Changes preserved
© Copyright Siemens AG







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)