PCB Relay. G2RL-1ATP7-E Datasheet

G2RL-1ATP7-E Relay. Datasheet pdf. Equivalent

G2RL-1ATP7-E Datasheet
Recommendation G2RL-1ATP7-E Datasheet
Part G2RL-1ATP7-E
Description PCB Relay
Feature G2RL-1ATP7-E; PCB Relay PCB Power Relay with Quick-connect Terminals ■ High switching capacity: 250 VAC, 16 A at 1.
Manufacture Omron
Datasheet
Download G2RL-1ATP7-E Datasheet




Omron G2RL-1ATP7-E
PCB Relay
PCB Power Relay with Quick-connect
Terminals
High switching capacity: 250 VAC, 16 A at 105°C.
Ideal for high temperature applications.
Coil insulation: Class F (UL508).
Low profile for total size reduction.
Easy wiring with quick-connect terminals.
Model with 5-mm pitch (RAST5) is also available.
RoHS Compliant
Application: Cooking ovens, electric heating, power supplies.
Ordering Information
Classification
5-mm pitch
7.5-mm pitch
Contact form
SPST-NO
Enclosure ratings
Flux protection
Note: When ordering, add the rated coil voltage to the model number.
Example: G2RL-1ATP7-E 12 VDC
Rated coil voltage
Model Number Legend
G2RL-@@@-@@VDC
123 45
1. Number of Poles
1: 1 pole
2. Contact Form
A: SPST-NO
3. Quick-connect Terminal Pitch
TP5: 5-mm pitch
TP7: 7.5-mm pitch
4. Classification
E: High capacity
5. Rated Coil Voltage
12, 24 VDC
G2RL-TP
Model
G2RL-1ATP5-E
G2RL-1ATP7-E
1



Omron G2RL-1ATP7-E
G2RL-TP
G2RL-TP
Specifications
Coils Ratings
Rated voltage
12 VDC
24 VDC
Rated current
33.3 mA
16.7 mA
Coil resistance
360
1,440
Must operate voltage
70% max. of the rated voltage
Must release voltage
10% min. of the rated voltage
Max. voltage
130% at 105°C of the rated voltage
Power consumption
Approx. 400 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.
Contact Ratings
Contact material
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Note: P level: λ60=0.1 x 10-6operations
Ag alloy (Cd free)
Resistive load (cosφ=1)
16 A at 250 VAC
16 A
440 VAC
16 A
4,000 VA
Characteristics
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
100 mmax.
15 ms max.
5 ms max.
Mechanical: 18,000 operations/hr
Electrical: 900 operations/hr at rated load
1,000 Mmin. (at 500 VDC)
5,000 VAC, 1 min between coil and contacts
1,000 VAC, 1 min between contacts of same polarity
10 kV (1.2 × 50 µs) between coil and contact
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s2
Malfunction: Energized:100 m/s2
Not energized:100 m/s2
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 50,000 operations min. (at 900 operations/hr)
–40 to 105°C (with no icing)
5% to 85%
Approx. 12 g
Note: Values in the above table are the initial values.
Approved Standards
UL508 (File No. E41643)/CSA C22.2 (No.14) (File No. LR31928)
Model
Contact form
Coil ratings
G2RL-1ATP7-E
SPST-NO (High capacity)
12 to 24 VDC
G2RL-1ATP5-E
Contact ratings
16 A at 250 VAC (General use)
16 A at 24 VDC (Resistive)
16 A at 250 VAC (Resistive), 105°C,
100,000 operations
VDE (EN61810-1): (License No. 119650)
Model
Contact form
G2RL-1ATP7-E
SPST-NO (High capacity)
G2RL-1ATP5-E
Coil ratings
12, 24 VDC
Contact ratings
16 A at 250 VAC (cosφ=1), 105°C,
100,000 operations
2



Omron G2RL-1ATP7-E
G2RL-TP
Engineering Data
Endurance at 105°C
10000
Maximum Switching
Power
100
G2RL-TP
1000
100
10
250 VAC resistive
load at 105°C
16
10
1
0 2 4 6 8 10 12 14 16 18
Switching current (A)
1
1
10 100 1000
Switching voltage (V)
Ambient temperature vs. Ambient Temperature vs.
Operating/Recovery Voltage Maximum Coil Voltage
G2RL-1ATP5-E/G2RL-1ATP7-E
100
(Quantity: 5)
90
80
70
60
50
40
30
20
Operating voltage
Recovery voltage
Max.
x
Min.
Max.
x
Min.
200
180
160
140
130
120
100
80
60
40
10
0 40 20 0 10 20 40 80 100
Ambient temperature (°C)
20
0
40 20 0 20 40 60 80 100105 120
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.
3







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)