Power Relay. G2RL-1A4 Datasheet

G2RL-1A4 Relay. Datasheet pdf. Equivalent

G2RL-1A4 Datasheet
Recommendation G2RL-1A4 Datasheet
Part G2RL-1A4
Description PCB Power Relay
Feature G2RL-1A4; G2RL PCB Power Relay Low Profile Power Relay with 15.7 mm height, ideal for incorporation in miniat.
Manufacture Omron
Datasheet
Download G2RL-1A4 Datasheet




Omron G2RL-1A4
G2RL
PCB Power Relay
Low Profile Power Relay
with 15.7 mm height, ideal for
incorporation in miniature
equipments
• A wide variety of single pole, double pole, high-capacity (16 A)
type and high-sensitivity type (250 mW) Relays are available.
• Low profile; 15.7 mm max. in height.
• Conforms to VDE (EN61810-1), UL508 and CSA22.2.
• IEC/EN 60335-1 conformed. (-HA Model)
• Satisfies ambient operating temperature requirement of 85°C
and 105°C (-CV Model).
• Clearance and creepage distance: 8 mm / 8 mm min.
• Coil insulation system: Class F (UL1446).
• G2RL-1(A)-E-ASI: TV3 Rating models available.
• IEC/EN 60079-15 conformed
(Except G2RL-1(A)-H, G2RL-1A-E-CV(-HA) Models).
RoHS Compliant
Application Examples
• Home appliances
• OA equipments
• Industrial machinery
Model Number Legend
G2RL- @@@-@-@-—@- @
123 4 5 6 7
1. Number of poles
3. Enclosure rating
1 : 1 pole
None : Flux protection
2 : 2 pole
2. Contact Form
None : SPDT (1c)
A : SPST-NO (1a)
4 : Sealed
4. Classification
None : Standard
E : High-capacity
H : High-sensitivity
Ordering Information
G
2
R
L
5. Contact Material
None : Standard (Ag-alloy, Cd free)
ASI : AgSnIn
6. Special Requirement
None : Standard
CV : 16 A, pinning 5 mm,
switching at 105°C
PW : Coil Holding Voltage type
7. Market Code
None : General purpose
HA : Home Appliance according
to IEC/EN60335-1
Terminal Shape
PCB terminals
Market Code
General
Purpose
Home
Application
Classification
Contact form
SPST-NO (1a)
Standard
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
SPST-NO (1a)
High-capacity
SPDT (1c)
High-sensitivity
Standard
SPST-NO (1a)
SPDT (1c)
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
High-capacity
SPST-NO (1a)
SPDT (1c)
Enclosure rating
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Model
G2RL-1A
G2RL-1A4
G2RL-1
G2RL-14
G2RL-2A
G2RL-2A4
G2RL-2
G2RL-2-ASI
G2RL-24
G2RL-1A-E
G2RL-1A-E-ASI
G2RL-1A-E-CV
G2RL-1A4-E
G2RL-1-E
G2RL-1-E-ASI
G2RL-1-E-PW
G2RL-14-E
G2RL-1A-H
G2RL-1-H
G2RL-1-HA
G2RL-2A-HA
G2RL-2-HA
G2RL-1A-E-HA
G2RL-1A-E-CV-HA
G2RL-1-E-HA
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A DC5
Rated coil voltage
However, the notation of the coil voltage on the product case will be marked as @@VDC.
Note 2. Place your order in tube (20 pcs/tube) units.
Note 3. Contact your OMRON sales representative for sealed models.
Rated coil voltage Minimum packing unit
5, 12, 24, 48 VDC
5, 12, 24 VDC
5, 12, 24, 48 VDC
5, 12, 24 VDC
5, 12, 24, 48 VDC
20 pcs/tube
5, 12, 24 VDC
1



Omron G2RL-1A4
G2RL
PCB Power Relay
Ratings
Coil
Standard,
High-
Capacity
High-
sensitivity
Item
Rated voltage
5 VDC
12 VDC
24 VDC
48 VDC
5 VDC
12 VDC
24 VDC
Rated current
(mA)
80.0
33.3
16.7
8.96
50
20.8
10.42
Coil resistance
(Ω)
62.5
360
1,440
5,358
96
576
2,304
Must operate voltage Must release voltage
(V)
(V)
% of rated voltage
70% max.
10% min.
10 to 32%*
75% max.
10%
Max. voltage
(V)
130%
(at 85°C)
Power consumption
(mW)
Approx. 400
Approx. 100*
Approx. 430
Approx. 250
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* These numbers are only for -PW type. Power consumption with Holding Voltage is approx.100mW. Please confirm the detail in page 6 Coil Voltage Reduction
(Holding Voltage).
Contacts: Flux Protection Type
Classification
Standard type (resistive load)
High-capacity type (resistive load) High-sensitivity type (resistive load)
Item
Model
1-pole
2-pole
1-pole
Contact type
Single
Contact material
Ag-alloy (Cd free)
Rated load
G
2
Rated carry current
R
L
Max. switching voltage
Max. switching current
12 A at 250 VAC
12 A at 24 VDC (See note)
12 A (See note)
12 A
8 A at 250 VAC
8 A at 30 VDC (See note)
16 A at 250 VAC
16 A at 24 VDC (See note)
8 A (70°C)/5 A (85°C)
(See note)
16 A (See note)
440 VAC, 300 VDC
8A
16 A
10 A at 250 VAC (See note)
10 A (See note)
10 A
Failure rate (P level)
(reference value*)
40 mA at 24 VDC
* This value was measured at a switching frequency of 120 operations/min.
Note: Contact your OMRON representative for the ratings on sealed models.
Characteristics
Flux Protection Type
Classification
Standard type
High-capacity type
High-sensitivity type
Item
Number of poles
1-pole
2-pole
1-pole
Contact resistance *1
100 mΩ max.
Operate (set) time
15 ms max.
Release (reset) time
5 ms max.
Insulation resistance *2
1,000 MΩ min.
Between coil and
contacts
5,000 VAC, 50/60 Hz for 1min
Dielectric
strength
Between contacts
of the same
polarity
1,000 VAC, 50/60 Hz for 1min
Between contacts
of different polarity
2,500 VAC, 50/60 Hz for 1min
Impulse withstand voltage
10 kV (1.2 x 50 μs)
Vibration Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
resistance Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock
Destruction
1,000 m/s2
resistance Malfunction
Energized: 100 m/s2, De-energized: 100 m/s2
Mechanical
20,000,000 operations (at 18,000 operations/hr)
G2RL-1A-E(-ASI,-HA),
G2RL-1-E(-ASI,-HA, -PW):
Durability Electrical *3
(resistive load)
G2RL-1A, G2RL-1(-HA):
G2RL-2(A)(-HA), G2RL-2-ASI:
50,000 operations at 250 VAC, 12 A 30,000 operations at 250 VAC, 8 A
30,000 operations at 24 VDC, 12 A 30,000 operations at 30 VDC, 8 A
30,000 operations at 250 VAC, 16 A
30,000 operations at 24 VDC, 16 A
G2RL-1A-E-CV(-HA):
G2RL-1(A)-H:
50,000 operations at 250 VAC, 10 A
50,000 operations at 250 VAC, 16 A
at 105°C
Ambient operating temperature
-40°C to 85°C (with no icing or condensation)
-40°C to 105°C (with no icing or condensation) by G2RL-1A-E-CV
Ambient operating humidity
5% to 85% (with no icing or condensation)
Weight
Approx. 12 g
Note 1. Values in the above table are the initial values at 23°C.
Note 2. Contact your OMRON sales representative for sealed models.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. 1,800 operations per hour.
2



Omron G2RL-1A4
G2RL
Engineering Data
Maximum Switching Capacity
1-pole Standard type
50
AC resistive load
10
5
DC resistive
load
1
0.5
1-pole High-capacity type
50
AC resistive load
10
5
DC resistive
load
1
0.5
PCB Power Relay
2-pole type
50
10
5
1
0.5
AC resistive load
DC resistive
load
0.1
0
5 10 20 30 50 100
500 1,000
Switching voltage (V)
High-sensitibity type
50
AC resistive load
10
5
DC resistive
load
1
0.5
0.1
0
5 10 20 30 50 100
500 1,000
Switching voltage (V)
Ambient Temperature vs. Rated
Carry Current
20
1-pole High-capacity type
16
15
1-pole Standard type
12
1-pole High-sensitivity type
10
8
2-pole type
5
0.1
0
5 10 20 30 50 100
500 1,000
Switching voltage (V)
0 10 20 30 40 50 60 70 80 85 90 100
Ambient temperature (°C)
Ambient Temperature vs. Must
Operate and Must Release Voltages
100
Sample:
90 G2RL-14-E 24 VDC
Number of relays: 5 pcs
80
70
60
50
40
30
20
10
Must operate voltage
Must release voltage
max.
X
min.
max.
X
min.
0
20
40
60
80
100 120
Ambient temperature (°C)
0.1
0
5 10 20 30 50 100
500 1,000
Switching voltage (V)
Ambient Temperature vs. Maximum
Coil Voltage
250
200
G
180
G2RL-1A-E-CV
2
R
150
L
130
110
100
Other type
50
0 10 20 30 40 50 60 70 80 85 90 100 105 110
Ambient temperature (°C)
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
3







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)