DC/DC Converter. R-78S3.3-0.1 Datasheet

R-78S3.3-0.1 Converter. Datasheet pdf. Equivalent

R-78S3.3-0.1 Datasheet
Recommendation R-78S3.3-0.1 Datasheet
Part R-78S3.3-0.1
Description DC/DC Converter
Feature R-78S3.3-0.1; Features Switching Regulator • Boost converter • Efficiency 93% , >80% with 10% load • Input ran.
Manufacture Recom
Datasheet
Download R-78S3.3-0.1 Datasheet




Recom R-78S3.3-0.1
Features
Switching
Regulator
• Boost converter
• Efficiency 93% , >80% with 10% load
• Input range down to 0.65V
• Continuous short circuit protection
• 7µA input current in standby
• -40°C to +100°C operation
• IEC/EN62368-1 certified, CB report
DC/DC Converter
R-78S
Description
The R-78S is a DC/DC boost converter designed to run from single cell batteries. The
input voltage range of 0.65V-3.3V means that alkaline, NiCd, NiMH, zinc-carbon or lithium
chemistry cells can be used to generate a stable 1.8V, 3.3V or 3.6V output to power microprocessors,
WLAN/Bluetooth modules and IoT systems. The very high efficiency and low standby consumption
can be used to extend battery lifetimes until the „last gasp“ to get the maximum available energy
out of the cell. The wide operating temperature of -40°C to +100°C, short circuit protection, OTP,
Class A EMC and 3-year warranty round off this high performance converter.
0.1 Amp
SIP4
Single Output
Selection Guide
Part
Number
Input
Voltage Range (3)
[VDC]
Output Output Efficiency (1)
Max. Capacitive
Voltage Current @ min Vin @ typ. Vin Load (2)
[VDC] [mA] [%] [%] [µF]
R-78S1.8-0.1 0.65-1.3 1.8 100 92 93 470
R-78S3.3-0.1 0.65-3.15 3.3 100 92 93 470
R-78S3.6-0.1 0.65-3.3 3.6 100 92 93 470
Notes:
Note1: Efficiency is tested at nom. input voltage and full load. (refer to Basic characterisitc below)
Note2: Max. Cap Load is tested by nominal input and full resistive load
Note3: For more information, please refer to “Line Derating” on page I-2
Model Numbering
R-78S-__-0.1
Output Voltage
Output Current
IEC/EN62368-1 certified
CB report, EAC
EN55032 compliant
Specifications (measured @ Ta= 25°C,1.5Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min. Typ. Max.
Input Voltage
R-78S1.8-0.1
R-78S3.3-0.1
R-78S3.6-0.1
1.2VDC
nom. Vin= 1.5VDC 0.65VDC
1.5VDC
1.2VDC
1.5VDC
1.5VDC
1.3VDC
3.15VDC
3.3VDC
Under Voltage Lockout
DC-DC OFF
0.4VDC
Overload Capability (4)
peak duty cycle 10%
150%, 10s
Vout=1.8VDC
100µA
Quiescent Current
Vout=3.3VDC
160µA
Vout=3.6VDC
180µA
Start-up time
Vout=1.8VDC, use E-cap 330µF
Vout=3.3VDC and 3.6VDC
4ms
2ms
Rise time
Vout=1.8VDC, use E-cap 330µF
Vout=3.3VDC and 3.6VDC
3.5ms
800µs
Internal Operating Frequency
1200kHz
Notes:
Note4: For more information, please refer to “Overload Capability Graph” on page I-2
continued on next page
www.recom-power.com
REV.: 5/2018
www.recom-power.com/eval-ref-boards
I-1



Recom R-78S3.3-0.1
DC/DC Converter
Specifications (measured @ Ta= 25°C,1.5Vin, full load and after warm-up unless otherwise stated)
Parameter
Minimum Load
Dropout Voltage
Output Ripple and Noise
ON/OFF CTRL
Input Current of CTRL pin
Standby Current
Efficiency vs. Load
100
R-78S1.8-0.1
Condition
Vout= 1.8VDC
Vout= 3.3VDC
Vout= 3.6VDC
20MHz BW, 10%-100% load
DC-DC ON
DC-DC OFF
100
80 80
60 60
40 40
20
1.3Vin
0
0 20 40 60
Output Current [%]
100
R-78S3.6-0.1
100
20
0
0
80
60
40
20
0
0
Line Derating
100
80
1.5Vin
2.0Vin
2.5Vin
3.0Vin
3.3Vin
20 40 60 80 100
Output Current [%]
Continuous Current
60
40
20
0
0.65
1.8Vout
3.3Vout
3.6Vout
1.2 1.45 1.8
2.4
1.3
Input Voltage [V]
3.0 3.3
3.15
www.recom-power.com
REV.: 5/2018
150
100
90
0
150
140
130
120
110
100
0.65
R-78S
Series
Min. Typ. Max.
0%
500mV
150mV
300mV
100mVp-p
Open or 0.7V VCTRL<Vin
Short to GND or VCTRL<0.1V
5µA
7µA
R-78S3.3-0.1
1.2Vin
1.5Vin
2.4Vin
3.0Vin
20 40 60 80 90 100
Output Current [%]
Overload Capability
Peak Current
Continuous Current
20 30
120 130
Time [s]
Peak Current
3.3Vout
3.6Vout
1.2 1.45 1.8
2.4
1.3 1.85 2.1
Input Voltage [V]
3.0 3.3
3.15
I-2



Recom R-78S3.3-0.1
DC/DC Converter
Specifications (measured @ Ta= 25°C,1.5Vin, full load and after warm-up unless otherwise stated)
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
Condition
low line to high line, full load
10% to 100% load
R-78S
Series
Value
±3.0% typ.
±0.3% typ.
±1.0% typ.
PROTECTIONS
Parameter
Short Circuit Protection (SCP)
Over Temperature Protection (OTP)
Condition
below 100mW
internal IC
150°C
130°C
Value
continuous, auto recovery
shutdown
restart after cooling down
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Operating Altitude
Operating Humidity
Pollution Degree
MTBF
Vibration
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
80
70
60
50
40
Condition
with derating (see graph)
non-condensing
according to MIL-HDBK-217F, G.B.
+25°C
+90°C
Value
-40°C to +100°C
+105°C
0.015%/°C
5000m
5% to 95% RH
PD2
89365 x 103 hours
6963 x 103 hours
10-55Hz, 2G, 30min along X, Y and Z axis
Vin1.0V, R78S1.8-0.1
Vin1.8V, R78S3.3-0.1
Vin2.0V, R78S3.6-0.1
Vin<1.0V, R78S1.8-0.1
Vin<1.8V, R78S3.3-0.1
Vin<2.0V, R78S3.6-0.1
20
0
-40 -20 0 20 40 60 80 90100 120
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Audio/video, information and communication technology equipment
Safety requirements (CB Scheme)
EAC
RoHs2+
Report / File Number
WD-SE-R-170351-00
RU-AT.49.09571
www.recom-power.com
continued on next page
REV.: 5/2018
Standard
IEC62368-1, 2nd Edition, 2014
EN62368-1, 2014
TP TC 004/2011
RoHS 2011/65/EU + AM2015/863
I-3