Document
KDZLVTF100
Zener Diode
(AEC-Q101 qualified)
●Outline
PD
1000
mW
●Features High reliability Small power mold type
●Inner Circuit
Data sheet
●Application Voltage regulation
●Structure Silicon Epitaxial Planar
●Absolute Maximum Ratings (Ta = 25ºC)
Parameter
Symbol
Power dissipation
PD
Junction temperature
Tj
Storage temperature
Tstg
●Packaging Specifications
Packing
Embossed Tape
Reel Size(mm)
180
Taping Width(mm)
8
Quantity(pcs)
3000
Taping Code
TR
Marking
7T
Limits
1000 150 -55 ~ 150
Unit
mW
℃
℃
www.rohm.com © 2019- ROHMCo., Ltd.All rights reserved.
1/6
2019/04/18_Rev.005
KDZLVTF Series
Data sheet
●Electrical Characteristics (Ta = 25ºC)
Symbol
VZ Rank(V)
Zener Voltage:VZ(V)(1)
Dynamic Impedance:ZZ(Ω) Reverse Current:IR(μA)
MIN. MAX. IZ(mA) MAX. IZ(mA) MAX. VR(V)
51
48.0 54.0
2
220
2
5 39.0
56
53.0 60.0
2
220
2
5 43.0
62
58.0 66.0
2
220
2
5 47.0
68
64.0 72.0
2
220
2
5 52.0
75
70.0 79.0
2
220
2
5 57.0
82
77.0 87.0
2
220
2
5 63.0
91
85.0 96.0
2
220
2
5 69.0
100
94.0 106.0
2
220
2
5 76.0
110
104.0 116.0
2
220
2
5 84.0
120
114.0 126.0
2
220
2
5 91.0
130
122.0 138.0
2
220
2
5 102.0
150
140.0 160.0
2
220
2
Note(1) VZ test time is 40ms.
5 120.0
●Markings
VZ Rank(V) 51 56 62 68 75 82
Marking
0T 1T 2T 3T 4T 5T
VZ Rank(V) 91 100 110 120 130 150
Marking
6T 7T 8T 9T AT BT
www.rohm.com © 2019- ROHMCo., Ltd.All rights reserved.
2/6
2019/04/18_Rev.005
KDZLVTF Series
●Characteristic Curves
Data sheet
www.rohm.com © 2019- ROHMCo., Ltd.All rights reserved.
3/6
2019/04/18_Rev.005
KDZLVTF100
●Characteristic Curves
Data sheet
www.rohm.com © 2019- ROHMCo., Ltd.All rights reserved.
4/6
2019/04/18_Rev.005
KDZLVTF100
●Characteristic Curves
Data sheet
www.rohm.com © 2019- ROHMCo., Ltd.All rights reserved.
5/6
2019/04/18_Rev.005
KDZLVTF100
●Dimension
Data sheet
SOD-123FL, [SC-109B], (PMDU)
●Taping (Unit:mm)
www.rohm.com © 2019- ROHMCo., Ltd.All rights reserved.
6/6
2019/04/18_Rev.005
Notice
Precaution on using ROHM Products 1. If you intend to use our Products in devices requiring extremely high reliability (such as medical equipment (Note 1),
aircraft/spacecraft, nuclear power controllers, etc.) and whose malfunction or failure may cause loss of human life, bodily injury or serious damage to property (“Specific Applications”), please consult with the ROHM sales
representative in advance. Unless otherwise agreed in writing by ROHM in advance, ROHM shall not be in any way
responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of any ROHM’s Products for Specific Applications.
(Note1) Medical Equipment Classification of the Specific Applications
JAPAN
USA
EU CHINA
CLASSⅢ CLASSⅣ
CLASSⅢ
CLASSⅡb CLASSⅢ
CLASSⅢ
2. ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which a failure or malfunction of our Products may cause. The following are examples of safety measures: [a] Installation of protection circuits or other protective devices to improve system sa.