DatasheetsPDF.com

BR101 Dataheets PDF



Part Number BR101
Manufacturers Formosa MS
Logo Formosa MS
Description SINGLE PHASE 10 AMP BRIDGE RECTIFIERS
Datasheet BR101 DatasheetBR101 Datasheet (PDF)

BR1005 THRU BR1010 SINGLE PHASE 10 AMP BRIDGE RECTIFIERS VOLTAGE RANGE 50 to 1000 Volts CURRENT 10.0 Amperes BR-10 FEATURES * Low forward voltage * Low leakage current * Mounting: Hole thru for #6 screw * Mounting position: Any .770(19.6) .730(18.5) HOLE FOR NO. 6 SCREW AC .296(7.5) .255(6.5) .052(1.3) DIA. .048(1.2) TYP. .750 MIN. (19.1) .520(13.2) .770(19.6) .480(12.2) .730(18.5) AC + Dimensions in inches and (millimeters) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating 25 C .

  BR101   BR101



Document
BR1005 THRU BR1010 SINGLE PHASE 10 AMP BRIDGE RECTIFIERS VOLTAGE RANGE 50 to 1000 Volts CURRENT 10.0 Amperes BR-10 FEATURES * Low forward voltage * Low leakage current * Mounting: Hole thru for #6 screw * Mounting position: Any .770(19.6) .730(18.5) HOLE FOR NO. 6 SCREW AC .296(7.5) .255(6.5) .052(1.3) DIA. .048(1.2) TYP. .750 MIN. (19.1) .520(13.2) .770(19.6) .480(12.2) .730(18.5) AC + Dimensions in inches and (millimeters) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. TYPE NUMBER Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current .375"(9.5mm) Lead Length at Tc=50 C Peak Forward Surge Current, 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Maximum Forward Voltage Drop per Bridge Element at 5.0A D.C. Maximum DC Reverse Current Ta=25 C at Rated DC Blocking Voltage Operating Temperature Range, TJ Storage Temperature Range, TSTG Ta=100 C BR1005 BR101 BR102 BR104 BR106 BR108 BR1010 UNITS 50 35 50 100 70 100 200 140 200 400 280 400 10 200 1.1 10 -65 -65 200 +125 +150 600 420 600 800 560 800 1000 700 1000 V V V A A V mA mA C C RATING AND CHARACTERISTIC CURVES (BR1005 THRU BR1010) FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE 12 10 8 6 4 2 0 Single Phase Half Wave 60Hz Resistive Or Inductive Load FIG.2-MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PEAK FORWARD SURGE CURRENT,(A) 250 AVERAGE FORWARD CURRENT,(A) 200 150 Tj=25 C 8.3ms Single Half Sine Wave JEDEC method 100 50 0 25 50 75 100 125 150 175 CASE TEMPERATURE,( C) 0 1 5 10 50 100 NUMBER OF CYCLES AT 60Hz FIG.3-TYPICAL FORWARD CHARACTERISTICS 50 INSTANTANEOUS FORWARD CURRENT,(A) FIG.4-TYPICAL REVERSE CHARACTERISTICS 50 3.0 1.0 Tj=25 C Pulse Width 300us 1% Duty Cycle REVERSE LEAKAGE CURRENT, (mA) 10 10 3.0 1.0 0.1 0.1 Tj=25 C .01 0 .2 .4 .6 .8 1.0 1.2 1.4 .01 0 20 40 60 80 100 120 140 FORWARD VOLT AGE,(V) PERCENT OF RATED PEAK REVERSE VOLT AGE, (%) .


BR101 BR101 BR101


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)