Flyback Transformer
Document 518
Flyback Transformer ForONSemiconductor NCP1027
The DA2077-AL flyback transformer has been specifically deve...
Description
Document 518
Flyback Transformer ForONSemiconductor NCP1027
The DA2077-AL flyback transformer has been specifically developed for use with ON Semiconductor’s NCP1027 Standby Power Supply for ATX Applications and is specified in Application Note AND8241/D. This transformer is designed for universal input, 85 – 265 Vac. It operates in continuous conduction mode within an input voltage range of 120 Vdc to 375 Vdc and at a 65 kHz switching frequency. Primary to secondary isolation is 2000 Vrms tested for one minute. Coilcraft can also custom engineer a transformer to meet your specific requirements. For free evaluation samples, contact Coilcraft or visit www.coilcraft.com.
Part number
Indaut c0taAn1c e DCR ma x (Ohm s) inLdeuacktaangcee2
±10% (mH)
pri sec aux
max (µH)
Turns ratio pri : sec pri : aux Output
DA2077-AL
3.4
2.53 0.042 0.574
114
1 : 0.06 1 : 0.15
5 V, 2 A (sec)
12.5 V, 10 mA (aux)
1. Inductance is for ...