AXIAL FAN. CFM-5010V-052-300 Datasheet

CFM-5010V-052-300 FAN. Datasheet pdf. Equivalent

Part CFM-5010V-052-300
Description DC AXIAL FAN
Feature Additional Resources: Product Page | 3D Model SERIES: CFM-50V │ DESCRIPTION: DC AXIAL FAN FEATURES •.
Manufacture CUI
Datasheet
Download CFM-5010V-052-300 Datasheet

Additional Resources: Product Page | 3D Model SERIES: CFM-50 CFM-5010V-052-300 Datasheet
Recommendation Recommendation Datasheet CFM-5010V-052-300 Datasheet





CFM-5010V-052-300
Additional Resources: Product Page | 3D Model
SERIES: CFM-50V DESCRIPTION: DC AXIAL FAN
FEATURES
• omniCOOLTM bearing system
• 50 x 50 mm frame
• multiple speed options for different cooling needs
• tachometer signal and rotation detect options available
• auto restart protection standard on all models
date 02/10/2020
page 1 of 9
MODEL
input
voltage
rated
(Vdc)
range
(Vdc)
input
current1
max
(mA)
input
power1
max
(W)
CFM-5010V-043-260
5
3.5~6
98
0.49
CFM-5010V-052-300
5
3.5~6
179
0.90
CFM-5010V-143-260
12 6~13.8 58
0.70
CFM-5010V-155-310
12 4.5~13.8 81
0.98
CFM-5015V-132-154
12 4.5~13.8 33
0.40
CFM-5015V-138-201
12 4.5~13.8 37
0.48
CFM-5015V-150-290
12 4.5~13.8 54
0.65
CFM-5015V-161-330
12 4.5~13.8 76
0.92
CFM-5015V-172-381
12
4.5~13.8
127
1.53
CFM-5015V-247-290
24 8~27.6 34
0.82
CFM-5015V-258-330
24 8~27.6 51
1.23
Notes:
1. At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes
2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure
3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
5. All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
PART NUMBER KEY
rated
speed1
typ
(RPM±15%)
4800
5800
4800
5800
3200
3800
5000
6100
7200
5000
6100
air
flow2
(CFM)
11.0
13.8
11.0
13.8
7.7
10.2
13.0
17.0
18.6
13.0
17.0
static
pressure3
(inch H2O)
0.11
0.15
0.11
0.15
0.07
0.12
0.17
0.23
0.31
0.17
0.23
noise4
max
(dBA)
25.6
30.7
25.6
30.7
15.4
20.1
29.0
33.0
38.1
29.0
33.0
CFM-5010V-043-260 - XX - CXX
Base Number
Fan Signals
“blank” = no signals
11 = rotation detector signal
20 = tachometer signal
Reserved for Custom
Configurations
cuidevices.com



CFM-5010V-052-300
Additional Resources: Product Page | 3D Model
CUI Devices SERIES: CFM-50V DESCRIPTION: DC AXIAL FAN
date 02/10/2020 page 2 of 9
INPUT
parameter
conditions/description
operating input voltage1
5 Vdc input models
12 Vdc input models
24 Vdc input models
starting voltage2
5 Vdc input models
12 Vdc input models
24 Vdc input models
Note:
1. See Model section on page 1 for specific input voltage ranges.
2. Starting voltage for model CFM-5010V-143-260 is 6 Vdc.
PERFORMANCE3
parameter
conditions/description
rated speed
at rated voltage, 25°C, after 10 minutes
air flow
static pressure
at 0 inch H2O, see performance curves
at 0 CFM, see performance curves
noise
at 1 m
Note:
3. See Model section on page 1 for specific values.
PROTECTIONS / FEATURES4
parameter
conditions/description
auto restart
on all models
rotation detector signal
available on “11” models
tachometer signal
available on “20” models
Notes: 4. See Application Notes for details.
SAFETY & COMPLIANCE
parameter
insulation resistance of frame
dielectric strength
safety approvals
EMI/EMC
life expectancy
RoHS
conditions/description
at 500 Vdc between internal stator and positive
lead wire
apply 500 Vac for 1 minute between housing and
positive lead wire
UL/cUL 507, TUV (EN 60950-1)
EN 61000-6-1:2007, EN 61000-6-3:2007+A1
at 40°C, 65% RH
yes
ENVIRONMENTAL
parameter
operating temperature
storage temperature
conditions/description
min
3.5
4.5
8
min
3200
7.7
0.07
15.4
min
min
10
min
-10
-40
typ
5
12
24
3.5
4.5
8
typ
typ
typ
70,000
typ
max
6
13.8
27.6
units
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
max
7200
18.6
0.31
38.1
units
RPM
CFM
inch H2O
dBA
max
units
max
units
MΩ
hours
max
70
70
units
°C
°C
cuidevices.com





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)