Power Transformer
DIMENSIONS in inches [millimeters]
ELECTRICAL SPECIFICATIONS
Primary Inductance (3, 4, 5 - 2,1): 12.8µH ± 20% @ 0.1Vrms, 100KHz
Primary DC Current Continuous (3, 4, 5 - 2, 1): 3.0A(dc) for temperature rise of 30°C maximum
Primary Incremental Current (or Peak Current): 3.28A(dc) typical for less than 20% reduction of inductance
Primary DC Resistance (3, 4, 5 - 2, 1): 0.031 ohm maximum on combined windings
Secondary DC Resistance (7 - 10): 0.17 ohm maximum
Turns Ratio: (3, 4, 5-2,1):(7-10) = 1.00:1.75 ± 5% Hipot Voltage: 500V(ac), 5 seconds (Between Primary and Secondary windings and to core)
Operating Temperature Range: -20°C + 85°C
NOTE: Terminals 3, 4, 5 and 2, 1 must be tied (shorted) for proper operation
65
0.606 [15.39] MAX
10 1
0.335 [8.51] MAX
0.695 [17.65] MAX
0.575 [14.60]
0.028 [0.71]
0.028 [0.71]
0.100 [2.54] TYP
FOOTPRINT DIAGRAM
TRANSFORMER SCHEMATIC
1 2
3 4 5
10
9
8 7 6
www.vishay.com 2
For technical questions, .