Features
• Supports CAN 2.0 and CA...
Description
MCP2542FD/4FD, MCP2542WFD/4WFD
CAN FD Transceiver with Wake-Up Pattern (WUP) Option
Features
Supports CAN 2.0 and CAN with Flexible Data Rate (CAN FD) Physical Layer Transceiver Requirements
Optimized for CAN FD at 2, 5 and 8 Mbps Operation - Maximum propagation delay: 120 ns - Loop delay symmetry: -10%/+10% (2 Mbps)
MCP2542FD/4FD: - Wake-up on CAN activity, 3.6 µs filter time
MCP2542WFD/4WFD: - Wake-up on Pattern (WUP), as specified in ISO11898-2:2015, 3.6 µs activity filter time
Implements ISO11898-2:2003, ISO11898-5:2007, and ISO/DIS11898-2:2015
Qualification: AEC-Q100 Rev. G, Grade 0 (-40°C to +150°C)
Very Low Standby Current (4 µA, typical) VIO Supply Pin to Interface Directly to CAN Controllers
and Microcontrollers with 1.8V to 5V I/O CAN Bus Pins are Disconnected when Device is
Unpowered - An unpowered node or brown-out event will not
load the CAN bus - Device is unpowered if VDD or VIO drop below its
POR level Detection of Ground F...