MITSUBISHI LINEAR ICs
M5174P
FLAME DETECTOR
DESCRIPTION
Monolithic integrated circuit M5174P is designed for the use o...
MITSUBISHI LINEAR ICs
M5174P
FLAME DETECTOR
DESCRIPTION
Monolithic integrated circuit M5174P is designed for the use of the flame detection circuil. It is composed of current amplifiers, a thyristor circuit, a couple of the relay drivers and a internal voltage
regulator. The current limiting circuit of the driver and internal two sets of shunt circuits parallely connected with relay protect the relay against the danger in an abnormal state of no signal flame. A differential amplifier configuration and a temperature-independent reference voltage source minimize the variation of the operating threshold level of the flame current detector.
FEATURES
Fail-safe system (The operating mode of two degrees of redundancy.)
Available input flame current ...................... 50,uA(max.) Minimumtollelance for operating threshold input current
........................................... ±20%(Ta=-20-+60°C)
APPLICATION
Flame detection circuit for a gaseous appliance
PIN CONFIGURATION...