Circuit Breakers
Circuit Breakers
R58 Series
Features
.250” (6.35mm) Quick Connect Terminals Cannot be Manually Tripped Visual Trip Indic...
Description
Circuit Breakers
R58 Series
Features
.250” (6.35mm) Quick Connect Terminals Cannot be Manually Tripped Visual Trip Indicator Push Button to Reset Breaker
Thermal Circuit Breaker
D40
.440 (11.18)
1.375 (34.93)
.500 (12.7)
.850 (21.59)
.425 (10.8)
.050 (1.27) Max Closed Position
.660 (16.76)
1.375 (34.93)
Knurled Nut Hex Nut
M11*1 Thread (Note) .312 (7.92)
NOTE: Indicator plate shown may NOT be available on all devices.
NTE Type No. R58−1A R58−2A R58−3A R58−4A R58−5A R58−6A R58−7A R58−8A R58−10A R58−12A R58−15A R58−20A R58−25A R58−30A R58−35A
Trip Times
Current Rating Amps 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 12.0 15.0 20.0 25.0 30.0 35.0
Maximuml Resistance Ohms 1.35 (Typ) 0.32 (Typ) 0.225 0.225 0.225 0.175 0.175 0.175 0.125 0.050 0.040 0.030 0.020 0.020 0.020
1 to 4 Amp Types
Rated Load
Trip Times
100%
No Trip
145%
Trip in 1 Hour
200%
10 to 45 Sec.
400%
3.0 to 14.0 Sec.
600%
1.4 to 7.0 Sec.
800%
0.75 to 4.3 Sec.
1000%
0.50 to...