SGX Europe Sp. z o.o. Building 11 Ligocka St. 103, 40-568 Katowice, Poland
T: +48 (0) 32 438 4778
E:
[email protected] www.sgxsensortech.com
SGX-7CO
Industrial Carbon Monoxide Sensor
(Application : Fixed Gas Detectors)
PERFORMANCE
Range
0 – 1000 ppm
Output Signal
Typical Baseline Range
(pure air)
Linearity
100 ± 20 nA/ppm <±2 ppm CO equivalent
Linear
Response time (T90) Maximum Overload
<30 s 2000 ppm
Long-Term Output Drift
Recommended Load Resistor
Repeatability
<5% per annum 10 ohms
<±1% CO equivalent
Resolution
< 0.5 ppm
Warranty
2 years
Bias
No Bias
PRODUCT DIMENSIONS
All dimensions in mm All tolerances ±0.15 mm
OPERATING CONDITIONS
Temperature Range Operating Humidity
-30°C to +50°C
15 – 90% RH (non-Condensing)
Pressure range
Operating Circuit Recommended Storage Temperature Expected Operating Life
800 to 1200 mbar See Application Note 2
0°C to 20°C > 24 Months in Air