DatasheetsPDF.com

TBA1-2413 Dataheets PDF



Part Number TBA1-2413
Manufacturers TRACO POWER
Logo TRACO POWER
Description DC/DC Converter
Datasheet TBA1-2413 DatasheetTBA1-2413 Datasheet (PDF)

DC/DC Converter TBA 1 Series, 1 Watt • Continuous short circuit protection • I/O isolation: 1’500 VDC • Operating temperature range -40 to +85 °C without derating • Input voltage ranges (±10%): 3.3, 5, 12, 24 VDC • High efficiency up to 82% • SIP-4 package • Unregulated outputs • 3-year product warranty Models Order Code TBA 1-0310 TBA 1-0311 TBA 1-0510 TBA 1-0511 TBA 1-0519 TBA 1-0512 TBA 1-0513 TBA 1-1211 TBA 1-1219 TBA 1-1212 TBA 1-1213 TBA 1-2411 TBA 1-2419 TBA 1-2412 TBA 1-2413 Input Vo.

  TBA1-2413   TBA1-2413


Document
DC/DC Converter TBA 1 Series, 1 Watt • Continuous short circuit protection • I/O isolation: 1’500 VDC • Operating temperature range -40 to +85 °C without derating • Input voltage ranges (±10%): 3.3, 5, 12, 24 VDC • High efficiency up to 82% • SIP-4 package • Unregulated outputs • 3-year product warranty Models Order Code TBA 1-0310 TBA 1-0311 TBA 1-0510 TBA 1-0511 TBA 1-0519 TBA 1-0512 TBA 1-0513 TBA 1-1211 TBA 1-1219 TBA 1-1212 TBA 1-1213 TBA 1-2411 TBA 1-2419 TBA 1-2412 TBA 1-2413 Input Voltage Range 2.97 - 3.63 VDC (3.3 VDC nom.) 4.5 - 5.5 VDC (5 VDC nom.) 10.8 - 13.2 VDC (12 VDC nom.) 21.6 - 26.4 VDC (24 VDC nom.) The TBA 1 is a 1 Watt DC/DC SIP converter series which is specifically designed to offer a low-cost solution with no concession on quality and lifetime. The new design improves on the industry standard features and offers an integrated continuous short circuit protection circuit, an operating temperature range from –40°C to 85°C without derating and I/O-isolation of 1’500 VDC. It offers a broad application range in any space and cost critical application. Output Voltage nom. 3.3 VDC 5 VDC 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 5 VDC 9 VDC 12 VDC 15 VDC 5 VDC 9 VDC 12 VDC 15 VDC Output Current max. 260 mA 200 mA 260 mA 200 mA 110 mA 80 mA 65 mA 200 mA 110 mA 80 mA 65 mA 200 mA 110 mA 80 mA 65 mA Efficiency typ. 73 % 76 % 75 % 79 % 80 % 82 % 82 % 79 % 79 % 80 % 80 % 79 % 80 % 82 % 82 % www.tracopower.com July 11, 2023 Page 1 / 4 TBA 1 Series, 1 Watt Input Specifications Input Current - At no load Surge Voltage Recommended Input Fuse Input Filter 3.3 Vin models: 30 mA typ. 5 Vin models: 25 mA typ. 12 Vin models: 15 mA typ. 24 Vin models: 10 mA typ. 3.3 Vin models: 5 VDC max. (1 s max.) 5 Vin models: 9 VDC max. (1 s max.) 12 Vin models: 18 VDC max. (1 s max.) 24 Vin models: 30 VDC max. (1 s max.) 3.3 Vin models: 800 mA (slow blow) 5 Vin models: 500 mA (slow blow) 12 Vin models: 200 mA (slow blow) 24 Vin models: 100 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal Capacitor (add. external 22 µF, ESR <0.1Ω, recommended) Output Specifications Voltage Set Accuracy Regulation Ripple and Noise - Input Variation (1% Vin step) - Load Variation - 20 MHz Bandwidth Capacitive Load Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection ±3% max. (at 60% for 5VDC models) ±3% max. (at 80% for other models) 1.5% max. See application note: www.tracopower.com/overview/tba1 65 mVp-p typ. 200 mVp-p max. 3.3 Vout models: 3'300 µF max. 5 Vout models: 2'200 µF max. 9 Vout models: 1'000 µF max. 12 Vout models: 470 µF max. 15 Vout models: 470 µF max. 10 % of Iout max. (Operation at lower load will not damage the converter, but it may not meet all specifications) ±0.02 %/K max. 30 ms max. Continuous, Automatic recovery Safety Specifications Safety Standards - IT / Multimedia Equipment Designed for EN 62368-1 (no certification) General Specifications Relative Humidity Temperature Ranges - Operating Temperature - Case Temperature - Storage Temperature Power Derating - High Temperature Cooling System Switching Frequency Insulation System Isolation Test Voltage Isolation Resistance Isolation Capacitance Reliability Washing Process - Input to Output, 60 s - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF 95% max. (non condensing) –40°C to +95°C +105°C max. –55°C to +125°C 5 %/K above 85°C See application note: www.tracopower.com/overview/tba1 Natural convection (20 LFM) 50 - 200 kHz (PWM) Functional Insulation 1'500 VDC 1'000 MΩ min. 30 pF max. 2'000'000 h (MIL-HDBK-217F, ground benign) Not allowed All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com July 11, 2023 Page 2 / 4 Housing Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Weight Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number Supporting Documents Overview Link (for additional Documents) TBA 1 Series, 1 Watt Plastic (UL 94 V-0 rated) Epoxy (UL 94 V-0 rated) Nickel-Iron (Alloy 42) Nickel (1.5 µm min.) Tin (3 µm min.), bright Plastic Case PCB Mount THD (Through-Hole Device) SIP4 Lead-Free Wave Soldering 265 °C / 5 s max. 1.6 g www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) e7e14ecf-5433-4036-a2c8-8023072beea4 www.tracopower.com/overview/tba1 All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com July 11, 2023 Page 3 / 4 0.50 (0.02).


TBA1-2412 TBA1-2413 STGWA40IH65DF


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)