Fan. FBA09A Datasheet

FBA09A Fan. Datasheet pdf. Equivalent

FBA09A Datasheet
Recommendation FBA09A Datasheet
Part FBA09A
Description Fan
Feature FBA09A; FBA09A (92 X 25.5L) EMINEBEA.COM Allowable Ambient Temperature Range: -10°C ~ +70°C (65%RH) (Operat.
Manufacture NMB-MAT
Datasheet
Download FBA09A Datasheet




NMB-MAT FBA09A
FBA09A (92 X 25.5L)
EMINEBEA.COM
Allowable Ambient Temperature Range:
-10°C ~ +70°C (65%RH) (Operating)
-40°C ~ +75°C (65%RH) (Storage)
(non-condensing environment)
Failure Rate: 10%
50,000 Hours (40°C, 65%RH)
Units:
inch
(mm)
.177
8 – (f4.5)
ROTATION
3.25
(82.5)
3.62
(92)
1.00
.157 (25.5) .157
(4) (4)
inlet
outlet
LR99935
NAME
PLATE
FLOW
Housing with solid corner type are available.
- Pin
+ Pin
˜ÊÓ" (Pa)
°ÓÎ 60
°£x 40
(min-1)
12V(24V)-H
3000
12V(24V)-M
12V(24V)-L 2000
Ps °äÇ 20
0
1000 N
12
Air Flow
(m3/min)
3
­ ®
£ää
.185
4 – (f4.7)
.185
4 – (f4.7)
Bearing: Hydro Wave Bearing
3.25
(82.5)
3.54
(90)
INLET SIDE
3.25
(82.5)
3.54
(90)
OUTLET SIDE
MODEL
FBA09A 12L
FBA09A 12M
FBA09A 12H
FBA09A 24L
FBA09A 24M
FBA09A 24H
Rotation: Clockwise
Rated
Voltage
Operating
Voltage
Current
Input
Power
Rated
Speed
Max.
Air Flow
Max. Static
Pressure
Noise Mass
(V)
(V)
(A)*1
(W)*1 (min-1)*1 CFM*1 (m3/min)*1 in H2O (Pa)*1 (dB)*1
(g)
12 7.0 ~ 13.8 110
12 7.0 ~ 13.8 150
12 7.0 ~ 13.8 255
1.32 2200 42.7
1.80 2450 48.0
2.70 2950 56.8
24 14.0 ~ 27.6
80
24 14.0 ~ 27.6 110
24 14.0 ~ 27.6 140
1.92 2200 42.7
2.64 2450 48.0
3.36 2900 56.8
Airflow Outlet: Air Out Over Struts
1.21
1.36
1.61
1.21
1.36
1.61
.10 25.5 27.0
.11 29.4 30.0
.16 42.1 35.0
110
110
110
.10 25.5 27.0
.11 29.4 30.0
.16 42.1 35.0
110
110
110
*1: Average Values in Free Air



NMB-MAT FBA09A
F E AT U R E S
Specifications of Various Sensors
LOCKED ROTOR ALARM SIGNAL
Signal given when
fan is running
Signal given when
fan is locked up
Available
Models
Part Number
Suffix
VH VH
Axial models 1BS
VL
V goes VL to VH
VL
FBK04F
S
2 PULSE PER REVOLUTION SIGNAL
FAL S
FCB S
Signal given when
fan is running
VH
VL
VL 1 Revolution
2PPR
Signal given when
fan is locked up
AB
Lock
If fan locks on VH, signal
stays locked. If fan locks
on VL, signal stays at VL
for a few hundred MS,
then moves to VH.
(A:B ˜1:5; A 100MS)
Available
Models
Part Number
Suffix
Axial models
except:
FBK04F
FBA06T
FBA08T
FCB
FAL
1BX
In Panaflo FBA series models,
a locked rotor alarm sensor is
available in all models.
For Blowers and Crossflo fans,
a locked sensor can be provided
as an option.
A pulse sensor that transmits
signals when the motor rotates
is also available as an option.
The 2 pulse per revolution
sensor output is available in all
FBA Series models except the
15 mm “T” versions.
Panaflo Built-in Connector System
Lead Wire Connectors:
Style: MASS TERMINATION (standard)
AMP P/N 173977-3
CRIMP TYPE (this style is a 2 piece assembly)
AMP P/N 175778-3 (housing)
AMP P/N 175102-1 (terminal)
Notes:
•Connector style effects lead wire guage.
Please refer to fan specs for further details.
All axial fans except the FBA06T, FBA08T and FBKO4F
versions come standard with the mass termination
connector. The FBA06T, FBA08T and FBKO4F fan leads are
connected directly to the PC board in the fan assembly.
All FCB Crossflo models and FAL Blower fan leads are
soldered directly to the PC board in the fan assembly.
2



NMB-MAT FBA09A
High Reliability with HWB (Hydro Wave Bearing)
Radial Direction
shaft
thrust plate
Axial Direction
bearing
(b) HWB
Figure 1: Pressure distribution in each load direction.
washer
HWB
thrust plate
stop ring
Figure 1: Construction of HWB
shaft
Panaflo’s unique hydrowave bearing (HWB) addresses the traditional weakness of sleeve bearings…axial fric-
tion. By utilizing our unique HWB system, the thrust plate “floats” on a circulating film of oil, which greatly
reduces the axial friction and the bearing’s deterioration. The HWB pattern on the bearing virtually eliminates
thrust plate contact which is depicted above.
As the shaft rotates it acts as a pump constantly circulating the oil in the radial, as well as the axial direction.
The sealed system and reservoirs of oil maintain the proper lubrication to minimize mechanical contact and
prolong the fan’s life expectancy. The radial direction analysis shown above is essentially the same as a tradi-
tional sleeve bearing. Panasonic’s unique HWB reduces the axial contact.
3