www.murata-ps.com
Typical units
IRS Series
Encapsulated Sixteenth-Brick DOSA-Compatible,
Wide Input Isolated DC-DC Converters
Output Voltage (V)
3.3
5
12
Output Current (A)
15
10
4.5
Input Voltage (V)
18-75
18-75
18-75
Optimized for harsh environments in industrial/railway applications, the IRS DC-DC converter
series offer regulated outputs in an industry-standard sixteen-brick fully encased package.
FEATURES
„„High efficiency synchronous flyback topology
„„18-75 Volts DC wide input range with 3.3, 5 and
12 Volts for Output voltage
„„Up to 54 Watts total output power with over-
temperature shutdown
„„Tiny 1.44" x 1.04" x 0.50" baseplate package
„„Industry standard DOSA "brick" format and pinout
„„Extensive self-protection shut down features
„„Small footprint DC-DC converter, ideal for high
current applications
„„2250 Volt Basic input/output isolation
„„Operating temperature range -40 to +85°C with
derating
„„Stable no-load operation with no required exter-
nal components
„„Certified to UL 60950-1, 2nd Edition, EN60950-1
safety approvals
PRODUCT OVERVIEW
The world of “brick” DC-DC converters has seen a
steady size reduction. The IRS series makes an-
other dramatic size shrink down to a “sixteenth-
brick” width (0.90 inches) while still retaining a
high power output and full 2250 Volt DC isolation.
The converter family accepts 18 to 75 Volts DC
inputs and delivers fixed outputs regulated to
within ±0.125%. The IRS converters are ideal for
industrial and railway applications, datacom and
telecom applications, cell phone towers, data
centers, server farms and network repeaters.
IRS outputs may be trimmed while delivering
fast settling to current step loads and no adverse
effects from higher capacitive loads. Excellent
ripple and noise specifications assure compatibility
to circuits using CPU’s, ASIC’s, programmable logic
Standard Baseplate Option
and FPGA’s. No minimum load is required. For
systems requiring controlled startup/shutdown,
an external remote On/Off control may use a switch,
transistor or digital logic.
Many self-protection features on the IRS series
avoid both converter and external circuit hazards.
These include input undervoltage lockout and
overtemperature shutdown. The output of these
DC-DC converters have current limit using the
“hiccup” autorestart technique and the outputs
may be short-circuited indefinitely. Additional
features include output overvoltage and reverse
conduction elimination.
The synchronous flyback topology yields high
efficiency for minimal heat buildup and “no fan”
operation.
Flanged Baseplate Option
SAFETY FEATURES
„„Basic insulation
„„2250Vdc input to output isolation
„„UL 60950-1, 2nd Edition
„„CAN/CSA-C22.2 NO. 60950-1
„„EN 60950-1
„„RoHS compliant
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
SDC_IRS Series.A01.D06  Page 1 of 26



muRata IRS-3.3-15-Q48
IRS Series
Encapsulated Sixteenth-Brick DOSA-Compatible,
Wide Input Isolated DC-DC Converters
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE
Output
Root Model
Vout Iout Power
(V) (A, max.) (W)
R/N (mV pk-pk)
Typ. Max.
Regulation (max.)
Line Load
IRS-3.3/15-Q48 3.3 15 49.5
90
125 ±0.15% ±0.3%
IRS-5/10-Q48
5 10 50
90
130 ±0.125% ±0.125%
IRS-12/4.5-Q48 12 4.5 54
115
150 ±0.125% ±0.125%
Vin Nom.
(V)
48
48
48
Input
Range Iin, no load
(V) (mA)
18-75
18-75
18-75
25
30
25
Iin, full
load (A)
1.16
1.14
1.24
Efficiency
Package
Min. Typ. Case (inches)
87.5% 89% 1.44 x 1.04 x 0.50
88% 91% 1.44 x 1.04 x 0.50
89% 91% 1.44 x 1.04 x 0.50
Please refer to the Part Number Structure when ordering.
All specifications are at nominal line voltage and full load, +25°C unless otherwise
noted. See detailed specifications. Output capacitors are 1 μF ceramic multilayer in
parallel with 10 μF.
I/O caps are necessary for our test equipment and may not be needed for your
application.
Regulation specifications describe output voltage deviations from a nominal/midpoint
value to either extreme (50% load step).
Iout = 13A max. if Vin < 36V.
Iout=8A max. if Vin <36V.
Iout = 3.5A max. if Vin < 36V.
PART NUMBER STRUCTURE
IR S - 12 / 4.5 - Q48 N F - C
Industrial-Railway
RoHS-6 Compliant
S = Sixteenth Brick
Nominal Output Voltage:
Voltage in Volts (V)
Maximum Rated Output Current
Current in Amps (A )
Baseplate
Blank = Standard Baseplate
F = Flanged Baseplate
See Mechanical Drawings for details
On/Off Control Logic:
N = Negative
P = Positive
Input Voltage Range:
Q48 = 18–75 Volts (48V nominal)
*Sense is included on the IRS-3.3/15-Q48 and IRS-5/10-Q48.
Examples:
IRS-3.3/15-Q48NF-C stands for Industrial Railway 1/16 Brick, 3.3Vout@15A, 18V-75Vin, Negative Logic, Flanged Baseplate, RoHS-6 Compliant.
IRS-12/4.5-Q48P-C stands for Industrial Railway 1/16 Brick, 12Vout@4.5A, 18V-75Vin, Positive Logic, Standard Baseplate, RoHS-6 Compliant.
Special quantity order is required.
Some model number combinations may not be available. See website or contact your local Murata sales representative.
www.murata-ps.com/support
SDC_IRS Series.A01.D06  Page 2 of 26



muRata IRS-3.3-15-Q48
IRS Series
Encapsulated Sixteenth-Brick DOSA-Compatible,
Wide Input Isolated DC-DC Converters
FUNCTIONAL SPECIFICATIONS, IRS-3.3/15-Q48
ABSOLUTE MAXIMUM RATINGS
Conditions [1]
Minimum
Typical/Nominal
Maximum
Units
Input Voltage, Continuous
Full temperature range
0
75 Vdc
Input Voltage, Transient
Operating or non-operating, 100 mS max.
duration
100 Vdc
Isolation Voltage
Input to output tested
2250
Vdc
Input Reverse Polarity
None, install external fuse
None Vdc
On/Off Remote Control
Power on or off, referred to -Vin
0
15 Vdc
Output Power
0 49.5 50 W
Output Current
Current-limited, no damage, short-circuit protected
0
15 15 A
Storage Temperature Range
Vin = Zero (no power)
-55
125 °C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating voltage range
18 48 75 Vdc
Recommended External Fuse
Fast blow
7A
Start-up threshold
Rising input voltage
16 17 17.9 Vdc
Undervoltage lockout [9]
Falling input voltage
15
16.25
17.50
Vdc
Overvoltage shutdown
Rising input voltage
None Vdc
Reverse Polarity Protection [11]
None, install external fuse
None Vdc
Internal Filter Type
LC
Input current
Full Load Conditions
Vin = nominal
1.16 1.19 A
Low Line
Vin = minimum, 13A load
2.63 2.72 A
Inrush Transient
0.4 A2-Sec.
Output in Short Circuit
100 200 mA
No Load Input current
Iout = minimum, unit=ON
25 60 mA
Shut-Down mode Input Current (Off, UV, OT)
5 10 mA
Reflected (back) ripple current [2]
Measured at input with specified filter
15 30 mA, pk-pk
Pre-biased startup
External output voltage < Vset
Monotonic
GENERAL and SAFETY
Efficiency
Vin=48V, full load
Vin=24V, full load
87.5 89
88.5 90.5
%
%
Isolation
Isolation Voltage, Input to Output
2250 Vdc
Isolation Voltage, Input to Baseplate
1500 Vdc
Isolation Voltage, Baseplate to Output
1500 Vdc
Insulation Safety Rating
Basic
Isolation Resistance
100 MΩ
Isolation Capacitance
1300 pF
Safety
Certified to UL-60950-1, IEC/EN60950-1, 2nd
Edition
Yes
Calculated MTBF [3]
Belcore, Telcordia SR-332, Method 1, Class 3,
ground fixed, Tcase=25°C
3.0
Hours x 106
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
250 280 310 KHz
Power Up Startup Time
Power On to Vout regulated
30 mS
On/Off Startup Time
Remote ON to Vout regulated
30 mS
Dynamic Load Response
50-75-50% load step, settling time to within
1% of Vout
100 200 µSec
Dynamic Load Peak Deviation
Same as above,
±180
±240
mV
FEATURES and OPTIONS
Remote On/Off Control [4]
"N" suffix
Negative Logic, ON state
ON=Pin grounded or external voltage
-0.1
0.8 Vdc
Negative Logic, OFF state
OFF=Pin open or external voltage
2.5
15 Vdc
Control Current
Open collector/drain, sourcing
1 2 mA
"P" suffix
Positive Logic, ON state
ON=Pin open or external voltage
10
15 Vdc
www.murata-ps.com/support
SDC_IRS Series.A01.D06  Page 3 of 26





@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)