DC-DC Converter. SLDM-06D1AL Datasheet

SLDM-06D1AL Converter. Datasheet pdf. Equivalent

SLDM-06D1AL Datasheet
Recommendation SLDM-06D1AL Datasheet
Part SLDM-06D1AL
Description Non-Isolated DC-DC Converter
Feature SLDM-06D1AL; SLDM-06D1Ax Non-Isolated DC-DC Converter The SLDM-06D1Ax power modules are non-isolated dc-dc conver.
Manufacture bel
Datasheet
Download SLDM-06D1AL Datasheet




bel SLDM-06D1AL
SLDM-06D1Ax
Non-Isolated DC-DC Converter
The SLDM-06D1Ax power modules are non-isolated dc-dc
converters that can deliver up to 6 A of output current. These
modules operate over a wide range of input voltage (VIN = 3 Vdc-
14.4 Vdc) and provide a precisely regulated output voltage from 0.45
Vdc to 5.5 Vdc, programmable via an external resistor and PMBus
control.
Features include a digital interface using the PMBus protocol,
remote On/Off, adjustable output voltage, over current and over
temperature protection in the controller. The PMBus interface
supports a range of commands to both control and monitor the
module.
The module also includes the Tunable LoopTM feature that allows the
user to optimize the dynamic response of the converter to match the
load with reduced amount of output capacitance leading to savings
on cost and PWB area.
Key Features & Benefits
3-14.4 VDC Input / 0.45-5.5 VDC @ 6 A Output
Non-Isolated
DOSA approved footprint
Power Good Signal
Remote On/Off
Digital interface through the PMBusTM protocol
Ability to Sink and Source Current
Output Over Current Protection (non-latching)
Over Temperature Protection
Small size: 20.32 mm x 11.43 mm x 2.8 mm (Max) (0.8 in x 0.45
in x 0.11 in)
Ultra low height design for very dense power applications.
Output voltage programmable from 0.6Vdc to 5.5Vdc via external
resistor.
Digitally adjustable down to 0.45Vdc
Digital interface through the PMBusTM protocol
Flexible output voltage sequencing EZ-SEQUENCE
Fixed switching frequency with capability of external
synchronization
Tunable LoopTM to optimize dynamic output voltage response
belpowersolutions.com



bel SLDM-06D1AL
2 SLDM-06D1Ax
Key Features & Benefits (Continued)
Wide operating temperature range [-40°C to 105°C].
Compliant to IPC-9592 (September 2008), Category 2, Class II
ISO 9001 and ISO 14001 certified manufacturing facilities
Compliant to RoHS II EU “Directive 2011/65/EU”
Compliant to REACH Directive (EC) No 1907/2006
Compatible in a Pb-free or SnPb reflow environment
UL 60950-1Recognized, CSA C22.2 No. 60950-1-03 Certified
VDE 0805:2001-12 (EN60950-1) Licensed
Applications
Distributed power architectures
Intermediate bus voltage applications
Telecommunications equipment
Servers and storage applications
Networking equipment
Industrial equipmen
tech.support@psbel.com
belpowersolutions.com



bel SLDM-06D1AL
SLDM-06D1Ax
3
1. MODEL SELECTION
MODEL
NUMBER
SLDM-06D1A0
SLDM-06D1AL
OUTPUT
VOLTAGE
0.45-5.5 VDC
0.45-5.5 VDC
INPUT
VOLTAGE
3-14.4 VDC
3-14.4 VDC
MAX. OUTPUT
CURRENT
6A
6A
MAX. OUTPUT
POWER
33 W
33 W
NOTE: 1. Add “R” suffix at the end of the model number to indicate tape and reel packaging (Standard).
2. Add “G” suffix at the end of the model number to indicate tray packaging (Option).
PART NUMBER EXPLANATION
TYPICAL EFFICIENCY
91.5%
91.5%
S
Mounting Type
Surface mount
LDM
RoHS
Status
Series
code
-
06
Output
Current
6A
D
Wide input
voltage range
3-14.4V
1A
Output
Voltage
With
sequencing
x
Enable
L – active Low
0 –active High
Y
Package Type
G – Tray package
R –tape and reel packaging
2. ABSOLUTE MAXIMUM RATINGS
PARAMETER
Continuous non-operating Input Voltage
Voltage on SEQ SYNC VS+
Voltage on CLK DATA SMBALERT
terminal
Ambient temperature
Storage Temperature
Altitude
DESC RIPT ION
See Thermal Considerations section
MIN
TYP
MAX
UNITS
-0.3 - 15 V
- - 7V
- - 3.6 V
-40 - 105 C
-55 - 125 C
- - 2000 m
NOTE: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
3. INPUT SPECIFICATIONS
All specifications are typical at 25°C unless otherwise stated.
PARAMETER
Operating Input Voltage
Input Current (full load)
Input Current (no load)
Input Stand-by Current
Vo=0.6V
Vo=5V
Input Reflected Ripple Current (pk-pk)
I2t Inrush Current Transient
Input Ripple Rejection (120Hz)
DESC RIPT ION
VIN=3V to 14V, IO=IO, max
VIN = 12Vdc, IO = 0, module enabled
VIN = 12.0Vdc, module disabled
5Hz to 20MHz, 1μH source impedance; VIN =0
to 14V, IO= IOmax
2. See Test Configurations
MIN
3
-
-
-
-
-
-
-
TYP
-
-
31.3
178.7
11
37.6
-
-55
MAX
14.4
6
-
-
-
-
1
-
UNIT
V
A
mA
mA
mA
mA
A2s
dB
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of
sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and
system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6A. Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used.
Refer to the fuse manufacturer’s data sheet for further information.
Note: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2016 Bel Power Solutions & Protection
North America
+1 408 785 5200
Rev. AC







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)