FMHR0212 DATA SHEET
Temperature Conditioned Low Loss TNC Female Bulkhead to N Male Cable LL160 Coax
Temperature conditioned low loss TNC Female Bulkhead to N Male cable assemblies with RF test reports from Fairview Microwave are part of our full line of reliable RF components available to ship same day. These COTS (commercial-off-theshelf) cable assemblies using LL160 triple shielded coax with expanded PTFE dielectric have traceable processes and materials that are recorded and provided in the included test report. The temperature pre-conditioned coaxial cable and captivated stainless steel RF connectors are assembled with J-STD-001 soldering processes and meet WHMA-A-620 workmanship criteria. The carefully selected materials, temperature conditioning, assembly processes and test sequence ensure a dependable cable assembly for high-reliability applications with wide temperature excursions and where the cost of failure is high. Each serialized TNC to N low loss cable assembly is traceable to its component lots and test data ships with every cable.
This low loss temperature tolerant hi-rel cable assembly using LL160 expanded PTFE cable datasheet PDF contains specifications, CAD drawing and dimensions that are shown below. Fairview Microwave offers these high-reliability RF cable assemblies with test data and many other RF, microwave and millimeter wave components which allow designers to configure and customize their signal systems however they like. Whether the need is to provide reliable interconnects over wide temperature extremes or have supporting test reports, Fairview Microwave has the right cable assemblies for the job. Fairview can also expertly build your custom RF cable assemblies for you and ship same day.
Referenced Specifications
IPC/WHMA-A-620 MIL-STD-348
IPC J-STD-001 IPC J-STD-006
SAE AS5942 SAE AS23053
Requirements and Acceptance for Cable and Wire Harness Assemblies
Radio Frequency Connector Interfaces for MILDTL-3643, MIL-DTL-3650, MIL-DTL-3655, MILDTL-25516, MIL-PRF-31031, MIL-PRF-39012, MIL-PRF-49142, MIL-PRF...
Requirements for Soldered Electrical and Electronic Assemblies
Requirements for Electronic Grade Solder Alloys and Fluxed and Non-Fluxed Solid Solders for Electronic Soldering Applications
Marking of Electrical Insulating Materials Insulation Sleeving, Electrical, Heat Shrinkable, General
Specifications For
Material Specifications Component Specification
Cable
LL160 per LL160 datasheet
Connector 1 FMCN1469 per MIL-STD-348
Connector 2 FMCN1471 per MIL-STD-348
Heat Shrink 1 SUMITUBE W3B2(4X) 12/3 per SAE AS23053 as applicable
Heat Shrink 2 SUMITUBE W3B2(4X) 12/3 per SAE AS23053 as applicable
Heat Shrink 3 M23053/4-303-0 per SAE AS23053
Heat Shrink 4 M23053/4-303-0 per SAE AS23053
Solder
SN63 per J-STD-006
Configuration:
• Connector 1: FMCN1469 (TNC Female Bulkhead) • Connector 2: FMCN1471 (N Male) • Cable: LL160
Features:
• Max Frequency 18 GHz • 82.5% Phase Velocity • Triple Shielded • FEP Jacket • Temperature Pre-Conditioned
Cable • J-STD Soldering • Lot Traceability • Captivated Stainless Steel Con-
nectors • Expanded PTFE dielectric • Serialized Test Data & Report • In-stock and ships same day
Applications:
• General Purpose • Laboratory Use • Extreme Temperatures • Hi-Reliability • Unmanned Systems • COTS Solutions • Avionics • Electronic
Countermeasures(ECM)
Cable Diagram:
Fairview Microwave 301 Leora Ln., Suite 100 Lewisville, TX 75056 Tel: 1-800-715-4396 / (972) 649-6678 Fax: (972) 649-6689 www.fairviewmicrowave.com
[email protected]
REV 1.1 Page 1 of 6 Copyright © 2019
FMHR0212 DATA SHEET
Electrical Specifications Description
Min Typ Max
Units .
Frequency Range
DC
18
GHz
VSWR 1.37:1
Velocity of Propagation
82.5
%
Capacitance 25 [82.02] pF/ft [pF/m]
Dielectric Withstanding Voltage (AC)
1,000
Vrms
Specifications by Frequency
Description
F1 F2
F3 F4
F5 Units .
Frequency
1 2 4.5 9 18 GHz
Insertion Loss (Max.) 0.11 0.16
0.24 0.35
0.51
dB/ft
0.36 0.52 0.79 1.15 1.67 dB/m
Electrical Specification Notes: Insertion Loss does not include the loss of the connectors. Insertion Loss is estimated as 0.04*SQRT(FGHz) dB per connector.
Mechanical Specifications Cable Assembly
Description
Min
Typ
Max
. Units
Cable Outer Diameter
0.155
0.16
0.165
in
Weight
0.17 [77.11] lbs [g]
Cable Characteristics
Component
Cable Type Impedance Inner Conductor Type Inner Conductor Mat. & Plat. Dielectric Type Number of Shields Shield Layer 1 Shield Layer 2 Shield Layer 3 Jacket Material
Specification
LL160 50 Ohms
Solid Copper, Silver Expanded PTFE Tape
3 Silver Plated Copper Aluminum Polyester Silver Plated Copper Wire
FEP
.