1. General description
The 74LV1T04 is a single, level translating inverting buffer. The low threshold inputs support 1.8 V input logic at VCC = 3.3 V and can be used in 1.8 V to 3.3 V level up translation. In addition, the 5 V tolerant input pins enable level down translation (3.3 V to 2.5 V output at VCC = 2.5 V). The output level is referenced to the supply voltage and supports 1.8 V, 2.5 V, 3.3 V and 5.0 V CMOS levels. The wide VCC range permits the generation of output levels to connect to controllers or processors.
2. Features and benefits
• Single supply voltage translator at 1.8 V, 2.5 V, 3.3 V and 5.0 V • Up translation
• 1.2 V to 1.8 V at VCC = 1.8 V • 1.5 V to 2.5 V at VCC = 2.5 V • 1.8 V to 3.3 V at VCC = 3.3 V • 3.3 V to 5.0 V at VCC = 5.0 V • Down translation • 3.3 V to 1.8 V at VCC = 1.8 V • 3.3 V to 2.5 V at VCC = 2.5 V • 5.0 V to 3.3 V at VCC = 3.3 V • 5 V tolerant inputs • Latch-up performance exceeds 250 mA per JESD 78 Class II • ESD protection: • HBM ANSI/ESDA/JEDEC JS-001 Class 2 exceeds 2 kV • CDM JESD22-C101 exceeds 1 kV • Specified from -40 °C to +85 °C and from -40 °C to +125 °C
3. Applications
• Portable applications • PC and notebooks • Industrial controller • Telecom
4. Ordering information
Table 1. Ordering information
Type number
Package
Temperature range
74LV1T04GW
-40 °C to +125 °C
Name TSSOP5
74LV1T04GV 74LV1T04GX
-40 °C to +125 °C -40 °C to +125 °C
SC-74A X2SON5
Description
plastic thin shrink small outline package; 5 leads; body width 1.25 mm
plastic surface-mounted package; 5 leads
plastic thermal enhanced extremely thin small outline package; no leads; 5 terminals; body 0.8 × 0.8 × 0.32 mm
Version SOT353-1
SOT753 SOT1226-3
Nexperia
74LV1T04
Single supply translating inverter
5. Marking
Table 2. Marking Type number 74LV1T04GW 74LV1T04GV 74LV1T04GX
Marking code[1] SG SG SG
[1] The pin 1 indicator is located on the lower left corner of the device, below the marking code.
6. Functional diagram
A
Y
mna108
Fig. 1. Logic symbol
1
mna109
Fig. 2. IEC logic symbol
7. Pinning information
A
Y
mna110
Fig. 3. Logic diagram
7.1. Pinning
74LV1T04
n.c. 1 A2
5 VCC
GND 3
4Y
aaa-027729
Fig. 4. Pin configuration SOT353-1 (TSSOP5) and SOT753 (SC-74A)
74LV1T04
n.c. 1
3 GND
5 VCC
A2
4Y
aaa-027730 Transparent top view
Fig. 5. Pin configuration SOT1226-3 (X2SON5)
7.2. Pin description
Table 3. Pin description
Symbol
Pin
n.c.
1
A
2
GND
3
Y
4
VCC
5
Description not connected data input ground (0 V) data output supply voltage
74LV1T04
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 7 February 2022
© Nexperia B.V. 2022. All rights reserved
2 / 12
Nexperia
8. Functional description
Table 4. Function table H = HIGH voltage level; L = LOW voltage level. Input A L H
74LV1T04
Single supply translating inverter
Output Y H L
9. Limiting values
Table 5. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Max Unit
VCC
supply voltage
VI
input voltage
VO
output voltage
output HIGH or LOW state output in power-off state
-0.5
+7.0 V
[1] -0.5
+7.0 V
[2][3] -0.5 VCC + 0.5 V
[2] -0.5
4.6 V
IIK IOK IO ICC IGND Tstg Ptot
input clamping current output clamping current output current supply current ground current storage temperature total power dissipation
VI < 0 V VO < 0 V or VO > VCC VO = 0 V to VCC
Tamb = -40 °C to +125 °C
-20
-
-
-
-50
-65
[4]
-
-
mA
±20 mA
±25 mA
50 mA
-
mA
+150 °C
250 mW
[1] If the input current ratings are observed, the minimum input voltage ratings may be exceeded. [2] If the output current ratings are observed, the output voltage ratings may be exceeded. [3] This value is limited to 7 V maximum. [4] For SOT353-1 (TSSOP5) package: Ptot derates linearly with 3.3 mW/K above 74 °C.
For SOT753 (SC-74A) package: Ptot derates linearly with 3.8 mW/K above 85 °C.
For SOT1226-3 (X2SON5) package: Ptot derates linearly with 3.0 mW/K above 67 °C.
10. Recommended operating conditions
Table 6. Recommended operating conditions Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
VCC VI VO Tamb Δt/ΔV
supply voltage input voltage output voltage ambient temperature input transition rise and fall rate
Conditions
output HIGH or LOW state VCC = 1.8 V to 5.0 V
Min
Typ
Max Unit
1.6
5.0
5.5 V
0
-
5.5 V
0
-
VCC V
-40
+25
+125 °C
-
-
20 ns/V
74LV1T04
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 7 February 2022
© Nexperia B.V. 2022. All rights reserved
3 / 12
Nexperia
74LV1T04
Single supply translating inverter
11. Static characteristics
Table 7. Static characteristics Voltages are referenced to GND (gr.