Features
Regulated Converter
• Universal input 85-264VAC • <150mW No load power consumption • Class II installations (without FG) • -25°C to +80°C Operating temperature • Continuous SCP, OCP • EN/IEC/UL60950, EN/IEC/UL62368 & EN60335-1 certified
AC/DC Converter
RAC01-GA
Description
The RAC01-GA series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input voltage range, regulated and short-circuit-proof isolated DC outputs, low standby power consumption and -25°C to +80°C operating temperature range. The RAC01-GA have a built-in Class A / FCC Part 15 EMC filter, are certified to EN60335, EN60950 and EN62368 safety standards and come with a three year warranty.
1 Watt Single Output EMC Class A
Selection Guide
Part Number
Input
Output
Output
Efficiency Max. Capacitive
Voltage Range Voltage
Current
typ (1) Load (2)
[VAC] [VDC] [mA] [%] [µF]
RAC01-05SGA 85-264 5 200 63 500
RAC01-12SGA 85-264 12 83 68 200
On Request RAC01-3.3SGA 85-264 3.3 303 63 RAC01-15SGA 85-264 15 66 63 RAC01-24SGA (3) 85-264 24 42 63
500 200 200
Notes: Note1: Measured with all input voltages at 25°C with constant resistant mode at full load Note2: Max Cap Load is tested at nominal input and full resisitive load Note3: Minimum order quantity ≥2000pcs
Model Numbering
RAC01-__ SGA
nom. Output Power
nom. Output Voltage
EMC Class A Single
E196683 IEC/EN60950-1 certified CAN/CSA-C22.2 No. 62368 pending UL62368-1 pending IEC/EN62368-1 pending EN60335-1 certified CB Report pending
Ordering Examples: RAC01-12SGA 12Vout Single Output EMC Class A
www.recom-power.com
REV.: 4/2018
PA-1
RAC01-GA
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS Parameter
Internal Input Filter Input Voltage Range (4,5,6) Input Current
Inrush Current No load Power Consumption Input Frequency Range Minimum Load Power Factor Start-up Time
Hold-up time Internal Operating Frequency
Output Ripple and Noise
Condition
nom. Vin= 230VAC
115VAC 230VAC
cold start at 25°C
115VAC 230VAC
115VAC, 230VAC
115VAC 230VAC 115VAC 230VAC
100% load at nominal Vin
20MHz BW
0°C to 80 °C -25 °C to 0 °C
5Vout 12Vout
5Vout 12Vout
Min. 85VAC
47Hz 0% 0.4
Typ. 230VAC 25mA 18mA
65kHz
Max. Pi-type
264VAC 30mA 20mA 30A 40A 150mW 63Hz
0.6 1s 2s 18ms 80ms
100mVp-p 200mVp-p 200mVp-p 300mVp-p
Notes: Note4: No proper operation with DC input voltage Note5: The products were submitted for safety files at AC-Input operation Note6: Refer to line derating graph on page 4
Efficiency [%] Efficiency [%]
Efficiency vs. Load
100 90 80 70 60 50 40 30 20 10 0
0
RAC01-05SGA
115VAC 230VAC 10 20 30 40 50 60 70 80 90 100 Output Load [%]
RAC01-12SGA
100
90
80
70
60
50
40
30
115VAC 230VAC
20
10
0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%]
www.recom-power.com
REV.: 4/2018
PA-2
RAC01-GA
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
REGULATIONS Parameter
Output Accuracy Line Regulation Load Regulation
Deviation vs. Load
Condition -25°C to +80°C -25°C to +80°C -25°C to +80°C
RAC01-05SGA
6
6
Series
RAC01-12SGA
Value ±6.0% max. ±2.0% max.
6.0% max.
44
115VAC
115VAC
2
230VAC
2
230VAC
Deviation [%] Deviation [%]
00
-2 -2
-4 -4
-6 0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
-6 0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
PROTECTIONS Parameter
Input Fuse (7) Short Circuit Protection (SCP) Over Voltage Category
Over Current Protection (OCP)
Class of Equipment Isolation Voltage (8) Isolation Resistance Insulation Grade Leakage Current
Type internal below 100mW
5Vout 12Vout
I/P to O/P
rated for 1 minute
I/P to O/P
Value fusible resistor, 1W/1W continuous, auto recovery
OVCII 0.22A - 0.5A, hiccup mode 0.25A - 0.91A, hiccup mode
Class II 3kVAC
100MΩ min. reinforced
0.25mA max.
Notes: Note7: Refer to local wiring regulations if input over-current protection is also required Note8: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note9: For operation at 230VAC, an external MOV is recommended. The Varistor should comply with IEC-61051-2. e.g. EPCOS S14 series
Protection Circuit for AC/DC Components (RAC‘s) + >230VAC operation (277VAC)
Protection Circuit
LN FUSE
U
www.recom-power.com
REV.: 4/2018
PA-3
RAC01-GA
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
ENVIRONMENTAL Parameter
Operating Temperature Range
Maximum Case Temperature Temperature Coefficient Operating Altitude (10) Operating Humidity Pollution Degree Shock Vibration
MTBF (11)
Condition
@ natural convection 0.1m/s
full load refer to derating graph
non-condensing
according to MIL-STD-202G according to MIL-HDBK-217F, method 2