DatasheetsPDF.com

74AC11013 Dataheets PDF



Part Number 74AC11013
Manufacturers Texas Instruments
Logo Texas Instruments
Description DUAL 4-INPUT POSITIVE-NAND SCHMITT TRIGGER
Datasheet 74AC11013 Datasheet74AC11013 Datasheet (PDF)

74AC11013 DUAL 4-INPUT POSITIVE-NAND SCHMITT TRIGGER • Operation From Very Slow Edges • Improved Line-Receiving Characteristics • High Noise Immunity • Flow-Through Architecture Optimizes PCB Layout • Center-Pin VCC and GND Configurations Minimize High-Speed Switching Noise • EPIC ™ (Enhanced-Performance Implanted CMOS) 1-µm Process • 500-mA Typical Latch-Up Immunity at 125°C • Package Options Include Plastic Small-Outline Packages and Standard Plastic 300-mil DIPs SCAS112 – MARCH 1990 – REVIS.

  74AC11013   74AC11013


Document
74AC11013 DUAL 4-INPUT POSITIVE-NAND SCHMITT TRIGGER • Operation From Very Slow Edges • Improved Line-Receiving Characteristics • High Noise Immunity • Flow-Through Architecture Optimizes PCB Layout • Center-Pin VCC and GND Configurations Minimize High-Speed Switching Noise • EPIC ™ (Enhanced-Performance Implanted CMOS) 1-µm Process • 500-mA Typical Latch-Up Immunity at 125°C • Package Options Include Plastic Small-Outline Packages and Standard Plastic 300-mil DIPs SCAS112 – MARCH 1990 – REVISED APRIL 1993 D OR N PACKAGE (TOP VIEW) 1B 1A 1Y GND 2Y 2D 2C 1 2 3 4 5 6 7 14 NC 13 1C 12 1D 11 VCC 10 2A 9 2B 8 NC description Each circuit functions as a 4-input NAND gate, but because of the Schmitt action, it has different input threshold levels for positive-going (VT+) and negative-going (VT–) signals. The 74AC11013 is characterized for operation from – 40°C to 85°C. FUNCTION TABLE INPUTS OUTPUT ABCD Y HHHH L LXXX H XLXX H XXLX H XXXL H EPIC is a trademark of Texas Instruments Incorporated. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 1993, Texas Instruments Incorporated •POST OFFICE BOX 655303 DALLAS, TEXAS 75265 •POST OFFICE BOX 1443 HOUSTON, TEXAS 77251–1443 1 74AC11013 DUAL 4-INPUT POSITIVE-NAND SCHMITT TRIGGER SCAS112 – MARCH 1990 – REVISED APRIL 1993 logic symbol† 2 1A 1 1B 13 1C 12 1D 10 2A 9 2B 7 2C 6 2D & 3 1Y 5 2Y † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. logic diagram (positive logic) 2 1A 1 1B 13 1C 12 1D 3 1Y 2A 10 9 2B 2C 7 6 2D 5 2Y •2 POST OFFICE BOX 655303 DALLAS, TEXAS 75265 •POST OFFICE BOX 1443 HOUSTON, TEXAS 77251–1443 74AC11013 DUAL 4-INPUT POSITIVE-NAND SCHMITT TRIGGER SCAS112 – MARCH 1990 – REVISED APRIL 1993 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous current through VCC or GND pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 100 mA Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –ā65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed. recommended operating conditions VCC Supply voltage VIH High-level input voltage VIL Low-level input voltage VI Input voltage VO Output voltage IOH High-level output current IOL Low-level output current ∆t /∆v TA Input transition rise or fall rate Operating free-air temperature VCC = 3 V VCC = 4.5 V VCC = 5.5 V VCC = 3 V VCC = 4.5 V VCC = 5.5 V VCC = 3 V VCC = 4.5 V VCC = 5.5 V VCC = 3 V VCC = 4.5 V VCC = 5.5 V MIN NOM MAX UNIT 3 5 5.5 V 2.2 3.2 V 3.9 0.5 0.9 V 1.1 0 VCC V 0 VCC V –4 – 24 mA – 24 12 24 mA 24 0 10 ns/ V – 40 85 °C •POST OFFICE BOX 655303 DALLAS, TEXAS 75265 •POST OFFICE BOX 1443 HOUSTON, TEXAS 77251–1443 3 74AC11013 DUAL 4-INPUT POSITIVE-NAND SCHMITT TRIGGER SCAS112 – MARCH 1990 – REVISED APRIL 1993 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VCC TA = 25°C MIN TYP MAX 3 V 2.2 VT+ 4.5 V 3.2 5.5 V 3.9 3 V 0.5 VT– 4.5 V 0.9 5.5 V 1.1 Vhys (VT+ – VT–) 3V 4.5 V 5.5 V 0.3 0.4 0.5 1.2 1.4 1.6 3 V 2.9 IOH = – 50 µA 4.5 V 5.5 V 4.4 5.4 VOH IOH = – 4 mA IOH = – 24 mA IOH = – 75 mA† 3V 4.5 V 5.5 V 5.5 V 3V 2.58 3.94 4.94 0.1 IOL.


74AC11011 74AC11013 54AC11021


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)