DatasheetsPDF.com

74AC11800 Dataheets PDF



Part Number 74AC11800
Manufacturers Texas Instruments
Logo Texas Instruments
Description TRIPLE 4-INPUT AND/NAND GATES
Datasheet 74AC11800 Datasheet74AC11800 Datasheet (PDF)

74AC11800 TRIPLE 4-INPUT AND/NAND GATES SCAS233 – AUGUST 1992 – REVISED APRIL 1993 • Suitable for Use in Applications Such as: – Differential Line Drivers – Complementary Input Circuits for Decoders and Code Converters • Flow-Through Architecture Optimizes PCB Layout • Center-Pin VCC and GND Pin Configurations Minimize High-Speed Switching Noise • EPIC™ (Enhanced-Performance Implanted CMOS) 1-µm Process • 500-mA Typical Latch-Up Immunity at 125°C description The 74AC11800 is a triple 4-input A.

  74AC11800   74AC11800



Document
74AC11800 TRIPLE 4-INPUT AND/NAND GATES SCAS233 – AUGUST 1992 – REVISED APRIL 1993 • Suitable for Use in Applications Such as: – Differential Line Drivers – Complementary Input Circuits for Decoders and Code Converters • Flow-Through Architecture Optimizes PCB Layout • Center-Pin VCC and GND Pin Configurations Minimize High-Speed Switching Noise • EPIC™ (Enhanced-Performance Implanted CMOS) 1-µm Process • 500-mA Typical Latch-Up Immunity at 125°C description The 74AC11800 is a triple 4-input AND/NAND gate. Elimination of decode spikes in symmetrical decoder and code-converter applications makes the device useful for applications such as a decoder or differential line driver. DW PACKAGE (TOP VIEW) 1A 1Y 1Z 2Y GND GND GND GND 2Z 3Y 3Z 3D 1 2 3 4 5 6 7 8 9 10 11 12 24 1B 23 1C 22 1D 21 2A 20 2B 19 VCC 18 VCC 17 2C 16 2D 15 3A 14 3B 13 3C The 74AC11800 is characterized for operation from – 40°C to 85°C. FUNCTION TABLE INPUTS OUTPUTS ABCDY Z LXXXLH XLXXLH XXLXLH XXXL LH HHHHH L logic symbol† logic diagram, each section (positive logic) 1 1A 24 & 2 1Y 1B 23 1C 3 22 1Z 1D 21 2A 20 4 2Y 2B 17 2C 9 16 2Z 2D 15 3A 14 10 3Y 3B 13 3C 11 12 3Z 3D † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. EPIC is a trademark of Texas Instruments Incorporated. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. A B C D •POST OFFICE BOX 655303 DALLAS, TEXAS 75265 Z Y Copyright © 1993, Texas Instruments Incorporated 2–1 74AC11800 TRIPLE 4-INPUT AND/NAND GATES SCAS233 – AUGUST 1992 – REVISED APRIL 1993 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡ Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±150 mA Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C ‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed. recommended operating conditions (see Note 2) VCC Supply voltage VIH High-level input voltage VIL Low-level input voltage VI Input voltage VO Output voltage IOH High-level output current IOL Low-level output current ∆t /∆v Input transition rise or fall rate TA Operating free-air temperature NOTE 2: Unused or floating inputs must be held high or low. VCC = 3 V VCC = 4.5 V VCC = 5.5 V VCC = 3 V VCC = 4.5 V VCC = 5.5 V VCC = 3 V VCC = 4.5 V VCC = 5.5 V VCC = 3 V VCC = 4.5 V VCC = 5.5 V MIN NOM MAX UNIT 3 5 5.5 V 2.1 3.15 V 3.85 0.9 1.35 V 1.65 0 VCC V 0 VCC V –4 – 24 mA – 24 12 24 mA 24 0 10 ns/ V – 40 85 °C 2–2 •POST OFFICE BOX 655303 DALLAS, TEXAS 75265 74AC11800 TRIPLE 4-INPUT AND/NAND GATES SCAS233 – AUGUST 1992 – REVISED APRIL 1993 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VCC TA = 25°C MIN TYP MAX 3 V 2.9 IOH = – 50 µA 4.5 V 5.5 V 4.4 5.4 VOH IOH = – 4 mA IOL = – 24 mA IOH = – 75 mA† 3V 4.5 V 5.5 V 5.5 V 3V 2.58 3.94 4.94 0.1 IOL = 50 µA 4.5 V 5.5 V 0.1 0.1 VOL IOL = 12 mA 3 V 0.36 IOL = 24 mA 4.5 V 5.5 V 0.36 0.36 IOL = 75 mA† 5.5 V II VI = VCC or GND 5.5 V ± 0.1 ICC VI = VCC or GND, IO = 0 5.5 V 4 Ci VI = VCC or GND 5V 4 † Not more than one output should be tested at a time, and the duration of the test sho.


74AC11652 74AC11800 74AC11828


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)