DatasheetsPDF.com

RT114009 Dataheets PDF



Part Number RT114009
Manufacturers TE
Logo TE
Description General Purpose Relays PCB Relays
Datasheet RT114009 DatasheetRT114009 Datasheet (PDF)

General Purpose Relays PCB Relays Power PCB Relay RT1 n 1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact n DC or AC coil n 5kV/10mm coil-contact, reinforced insulation n Ambient temperature 85°C (DC coil) n WG version: product in accordance to IEC 60335-1 n Reflow version: for THR (Through-Hole Reflow) soldering process SCHRACK Typical applications Boiler control, timers, garage door control, POS automation, interface modules Approvals VDE Cert. No. 40007571, cULus E214025, cCSAus 114.

  RT114009   RT114009


Document
General Purpose Relays PCB Relays Power PCB Relay RT1 n 1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact n DC or AC coil n 5kV/10mm coil-contact, reinforced insulation n Ambient temperature 85°C (DC coil) n WG version: product in accordance to IEC 60335-1 n Reflow version: for THR (Through-Hole Reflow) soldering process SCHRACK Typical applications Boiler control, timers, garage door control, POS automation, interface modules Approvals VDE Cert. No. 40007571, cULus E214025, cCSAus 1142018; CQC 18002197247 Technical data of approved types on request Contact Data 12A 16A Contact arrangement 1 form C (CO) or 1 form A (NO) Rated voltage 250VAC Max. switching voltage 400VAC Rated current 12A 16A Limiting continuous current 12A 16A, UL: 20A Limiting making current max. 4s, duty factor 10% 25A 30A Breaking capacity max. 3000VA 4000VA Contact material AgNi 90/10, AgNi 90/10 gold plated Frequency of operation, with/without load DC coil AC coil 360/72000h-1 360/36000h-1 Operate/release time max., DC coil 8/6ms Bounce time max., DC coil, form A/form B 4/6ms Electrical endurance see electrical endurance graph1) Contact ratings Type Contact Load Cycles IEC 61810 RT314 DC-coil A (NO) RT314 DC-coil C (CO) RT314 DC-coil A (NO) RT114 DC-coil A (NO) RT114 AC-coil A (NO) 16A, 250VAC, cosφ=1, 85°C 16A, 250VAC, cosφ=1, 85°C 10A, 400VAC, cosφ=1, 85°C 12A, 250VAC, cosφ=1, 85°C 12A, 250VAC, cosφ=1, 70°C 30x103 10x103 150x103 50x103 100x103 UL 508 RT314 RT334 RT314 RT314 A/B (NO/NC) 20A, 250VAC, general purpose, 85°C 6x103 A (NO) 16A, 250VAC, gen. purpose, 85°C 50x103 A (NO) 1hp, 240VAC, 40°C 1x103 A (NO) FLA/LRA, 4.5/13.1A, 480VAC, 70°C 100x103 EN60947-4-1 RT314 A (NO) 250V/2A, AC-3 6.050 F0144-C Zb EN60947-5-1 RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13 6.050 RT314 A (NO) 250/3A, AC-15 6.050 EN60730-1 RT314 DC-coil A (NO) 12(2)A, 250VAC, 85°C 100x103 1) For reflow solderable versions: actual contact performance may be influenced by the reflow soldering process. Contact Data (continued) Mechanical endurance DC coil AC coil AC coil, reflow version >30x106 operations >10x106 operations >5x106 operations Coil Data Coil voltage range, DC coil/ AC coil 5 to 110VDC / 24 to 230VAC Operative range, IEC 61810 2 Coil insulation system according UL class F Coil versions, DC coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±10%2) mW 005 5 3.5 0.5 62 403 006 6 4.2 0.6 90 400 009 9 6.3 0.9 200 400 012 12 8.4 1.2 360 400 018 18 12.6 1.8 770 420 020 20 14.0 2.0 952 420 024 24 16.8 2.4 1440 400 048 48 33.6 4.8 5520 417 060 60 42.0 6.0 85702) 420 110 110 77.0 11.0 288002) 420 2) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient temperature +23°C. Other coil voltages on request. Coil versions, AC coil 50/60 Hz Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VAC VAC VAC Ω±15%3) VA 524 24 18.0 3.6 3503) 0.76 548 48 36.0 7.2 1420 0.74 615 115 86.3 17.3 8100 0.76 620 120 90.0 18.0 8800 0.75 700 200 150.0 30.0 24350 0.76 730 230 172.5 34.5 32500 0.74 3) Coil resistance ±10%. All figures are given for coil without pre-energization, at ambient temperature +23°C, 50 Hz. 11-2020, Rev. 1120 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. 1 Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec- terms of the disclaimer and all chapters of tion, application notes and all specifications the ‘Definitions’ section, available at are subject to change. http://relays.te.com/definitions General Purpose Relays PCB Relays Power PCB Relay RT1 (Continued) SCHRACK form A/form B contact, 30 to 500Hz Shock resistance (destructive) 20g/5g 100g Other coil voltages on request. Insulation Data Initial dielectric strength between open contacts between contact and coil Clearance/creepage between contact and coil Material group of insulation parts Tracking index of relay base reflow version 1000Vrms 5000Vrms ≥10/10mm IIIa PTI 250V PTI 175V Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Resistance to heat and fire WG version or Reflow version according EN60335, par30 Ambient temperature DC coil -40 to 85°C AC coil -40 to 70°C Category of environmental protection, IEC 61810 standard version RTII - flux proof, RTIII - wash tight reflow version RTII - flux proof Vibration resistan.


RTB84009 RT114009 RT114012


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)