Document
General Purpose Relays PCB Relays
Power PCB Relay RT1
n 1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact n DC or AC coil n 5kV/10mm coil-contact, reinforced insulation n Ambient temperature 85°C (DC coil) n WG version: product in accordance to IEC 60335-1 n Reflow version: for THR (Through-Hole Reflow) soldering process
SCHRACK
Typical applications Boiler control, timers, garage door control, POS automation, interface modules
Approvals
VDE Cert. No. 40007571, cULus E214025, cCSAus 1142018; CQC 18002197247
Technical data of approved types on request
Contact Data
12A
16A
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
12A
16A
Limiting continuous current
12A
16A, UL: 20A
Limiting making current
max. 4s, duty factor 10%
25A
30A
Breaking capacity max.
3000VA
4000VA
Contact material AgNi 90/10, AgNi 90/10 gold plated
Frequency of operation, with/without load DC coil AC coil
360/72000h-1 360/36000h-1
Operate/release time max., DC coil
8/6ms
Bounce time max., DC coil, form A/form B
4/6ms
Electrical endurance see electrical endurance graph1)
Contact ratings
Type
Contact
Load
Cycles
IEC 61810 RT314 DC-coil A (NO) RT314 DC-coil C (CO) RT314 DC-coil A (NO) RT114 DC-coil A (NO) RT114 AC-coil A (NO)
16A, 250VAC, cosφ=1, 85°C 16A, 250VAC, cosφ=1, 85°C 10A, 400VAC, cosφ=1, 85°C 12A, 250VAC, cosφ=1, 85°C 12A, 250VAC, cosφ=1, 70°C
30x103 10x103 150x103 50x103 100x103
UL 508 RT314 RT334 RT314 RT314
A/B (NO/NC) 20A, 250VAC, general purpose, 85°C 6x103
A (NO)
16A, 250VAC, gen. purpose, 85°C 50x103
A (NO)
1hp, 240VAC, 40°C
1x103
A (NO)
FLA/LRA, 4.5/13.1A, 480VAC, 70°C 100x103
EN60947-4-1
RT314
A (NO)
250V/2A, AC-3
6.050
F0144-C
Zb
EN60947-5-1
RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13
6.050
RT314
A (NO)
250/3A, AC-15
6.050
EN60730-1
RT314 DC-coil A (NO)
12(2)A, 250VAC, 85°C
100x103
1) For reflow solderable versions: actual contact performance may be influenced by the
reflow soldering process.
Contact Data (continued)
Mechanical endurance DC coil AC coil AC coil, reflow version
>30x106 operations >10x106 operations >5x106 operations
Coil Data
Coil voltage range, DC coil/ AC coil 5 to 110VDC / 24 to 230VAC
Operative range, IEC 61810
2
Coil insulation system according UL
class F
Coil versions, DC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%2)
mW
005
5
3.5
0.5
62
403
006
6
4.2
0.6
90
400
009
9
6.3
0.9
200
400
012
12
8.4
1.2
360
400
018
18
12.6
1.8
770
420
020
20
14.0
2.0
952
420
024
24
16.8
2.4
1440
400
048
48
33.6
4.8
5520
417
060
60
42.0
6.0
85702)
420
110
110
77.0
11.0
288002)
420
2) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Coil versions, AC coil 50/60 Hz
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VAC
VAC
VAC
Ω±15%3)
VA
524
24
18.0
3.6
3503)
0.76
548
48
36.0
7.2
1420
0.74
615
115
86.3
17.3
8100
0.76
620
120
90.0
18.0
8800
0.75
700
200
150.0
30.0
24350
0.76
730
230
172.5
34.5
32500
0.74
3) Coil resistance ±10%.
All figures are given for coil without pre-energization, at ambient temperature +23°C, 50 Hz.
11-2020, Rev. 1120 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions
General Purpose Relays PCB Relays
Power PCB Relay RT1 (Continued)
SCHRACK
form A/form B contact, 30 to 500Hz Shock resistance (destructive)
20g/5g 100g
Other coil voltages on request.
Insulation Data
Initial dielectric strength between open contacts between contact and coil
Clearance/creepage between contact and coil
Material group of insulation parts Tracking index of relay base
reflow version
1000Vrms 5000Vrms
≥10/10mm IIIa
PTI 250V PTI 175V
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Resistance to heat and fire
WG version or Reflow version according EN60335, par30
Ambient temperature
DC coil
-40 to 85°C
AC coil
-40 to 70°C
Category of environmental protection, IEC 61810
standard version RTII - flux proof, RTIII - wash tight
reflow version
RTII - flux proof
Vibration resistan.