RT314730 Datasheet: General Purpose Relays PCB Relays





RT314730 General Purpose Relays PCB Relays Datasheet

Part Number RT314730
Description General Purpose Relays PCB Relays
Manufacture TE
Total Page 4 Pages
PDF Download Download RT314730 Datasheet PDF

Features: General Purpose Relays PCB Relays Power PCB Relay RT1 n 1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact n DC or AC coil n 5kV/10mm coil-contact, reinf orced insulation n Ambient temperature 85°C (DC coil) n WG version: product i n accordance to IEC 60335-1 n Reflow ve rsion: for THR (Through-Hole Reflow) so ldering process SCHRACK Typical appli cations Boiler control, timers, garage door control, POS automation, interface modules Approvals VDE Cert. No. 400 07571, cULus E214025, cCSAus 1142018; C QC in preparation Technical data of app roved types on request Contact Data 12A 16A Contact arrangement 1 f orm C (CO) or 1 form A (NO) Rated vol tage 250VAC Max. switching voltage 400VAC Rated current 12A 16A Limiting continuous current 12A 16 A, UL: 20A Limiting making current max. 4s, duty factor 10% 25A 30A B reaking capacity max. 3000VA 4000V A Contact material AgNi 90/10, AgNi 9 0/10 gold plated Frequency of operation, with/without load D.

Keywords: RT314730, datasheet, pdf, TE, General, Purpose, Relays, PCB, Relays, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute, Equivalent

General Purpose Relays
PCB Relays
Power PCB Relay RT1
n 1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact
n DC or AC coil
n 5kV/10mm coil-contact, reinforced insulation
n Ambient temperature 85°C (DC coil)
n WG version: product in accordance to IEC 60335-1
n Reflow version: for THR (Through-Hole Reflow) soldering process
SCHRACK
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
Approvals
VDE Cert. No. 40007571, cULus E214025, cCSAus 1142018;
CQC in preparation
Technical data of approved types on request
Contact Data
12A
16A
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
12A
16A
Limiting continuous current
12A
16A, UL: 20A
Limiting making current
max. 4s, duty factor 10%
25A
30A
Breaking capacity max.
3000VA
4000VA
Contact material AgNi 90/10, AgNi 90/10 gold plated
Frequency of operation, with/without load
DC coil
360/72000h-1
AC coil
360/36000h-1
Operate/release time max., DC coil
8/6ms
Bounce time max., DC coil, form A/form B
4/6ms
Electrical endurance see electrical endurance graph1)
Contact ratings
Type
Contact Load
Cycles
IEC 61810
RT314 DC-coil A (NO)
RT314 DC-coil C (CO)
RT314 DC-coil A (NO)
RT114 DC-coil A (NO)
RT114 AC-coil A (NO)
UL 508
16A, 250VAC, cosφ=1, 85°C
16A, 250VAC, cosφ=1, 85°C
10A, 400VAC, cosφ=1, 85°C
12A, 250VAC, cosφ=1, 85°C
12A, 250VAC, cosφ=1, 70°C
30x103
10x103
150x103
50x103
100x103
RT314
A/B (NO/NC) 20A, 250VAC, general purpose, 85°C 6x103
RT334
A (NO)
16A, 250VAC, gen. purpose, 85°C 50x103
RT314
A (NO)
1hp, 240VAC, 40°C
1x103
RT314
A (NO)
FLA/LRA, 4.5/13.1A, 480VAC, 70°C 100x103
EN60947-4-1
RT314 DC-coil A (NO)
250V/6A, AC-3
6.050
RT314 AC-coil A (NO)
250V/2A, AC-3
6.050
F0144-C
Zb
EN60947-5-1
RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13
6.050
EN60730-1
RT314 DC-coil A (NO)
12(2)A, 250VAC, 85°C
100x103
1) For reflow solderable versions: actual contact performance may be influenced by the
reflow soldering process.
Contact Data (continued)
Mechanical endurance
DC coil
AC coil
AC coil, reflow version
>30x106 operations
>10x106 operations
>5x106 operations
Coil Data
Coil voltage range, DC coil/ AC coil 5 to 110VDC / 24 to 230VAC
Operative range, IEC 61810
2
Coil insulation system according UL
class F
Coil versions, DC coil
Coil
Rated
Operate Release
Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10%2) mW
005 5 3.5 0.5 62 403
006 6 4.2 0.6 90 400
009 9 6.3 0.9 200 400
012 12 8.4 1.2 360 400
018 18 12.6 1.8 770 420
020 20 14.0 2.0 952 420
024 24 16.8 2.4 1440 400
048 48 33.6 4.8 5520 417
060
60 42.0
6.0 85702) 420
110 110 77.0 11.0 288002) 420
2) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Coil versions, AC coil 50/60 Hz
Coil
Rated
Operate Release
Coil Rated coil
code voltage voltage voltage resistance power
VAC VAC VAC Ω±15%3) VA
524
24 18.0
3.6 3503) 0.76
548
48 36.0
7.2 1420 0.74
615 115 86.3 17.3 8100 0.76
620 120 90.0 18.0 8800 0.75
700
200
150.0
30.0
24350
0.76
730
230
172.5
34.5
32500
0.74
3) Coil resistance ±10%.
All figures are given for coil without pre-energization, at ambient temperature +23°C, 50 Hz.
Other coil voltages on request.
02-2019, Rev. 0219
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1

           






Index : 0  1  2  3   4  5  6  7   8  9  A  B   C  D  E  F   G  H  I  J   K  L  M  N   O  P  Q  R   S  T  U  V   W  X  Y  Z
@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)