Document
General Purpose Relays PCB Relays
Power PCB Relay RZ
n 1 pole 12/16 A, 1 form C (CO) or 1 form A (NO) contact n DC coil 400 mW n 5kV/10mm coil-contact, reinforced insulation n Ambient temperature 85°C n Product in accordance to IEC 60335-1 n Reflow version for THR mounting process
SCHRACK
Typical applications Household appliances, boiler control, timers, garage door control, POS automation
Approvals
VDE Cert. No. 40023970, UL E214025, CQC 12002066685
Technical data of approved types on request
Contact Data
12A
16A
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
12A
16A
Limiting making current (form A contact)
max. 4s, duty factor 10%
30A
max. 20ms (incandescent lamp); AgSnO2 80A
Breaking capacity max.
3000VA
4000VA
Contact material AgNi 90/10 or AgSnO2 Frequency of operation, with/without load 360/72000h-1
Operate/release time max.
8/6ms
Bounce time max., form A/form B
4/10ms
Contact ratings for standard version
Type
Contact Load
IEC 61810
RZ03-1A4 A (NO)
16A, 250VAC, 85°C
RZ03-1C4 C (CO)
16A, 250VAC, 85°C
RZ01-1A3 A (NO)
12A, 250VAC, 85°C
RZ01-1A4 A (NO)
12A, 250VAC, 85°C
RZ01-1C4 C (CO)
12A, 250VAC, 85°C
RZ01/3-1A4 A (NO)
10A, 250VAC, 85°C
RZ0H-1A4 A (NO)
12A, 250VAC, 85°C
RZ0H-1A4 A (NO)
16A, 250VAC, 85°C
RZ0H-1A4 A (NO)
18A, 250VAC, 85°C
UL 508
RZ03-1A. A (NO)
16A, 250VAC, 85°C
RZ03-1A4 A (NO)
12A, 250VAC, 85°C
RZ01-1A3 A (NO)
12A, 250VAC, 85°C
RZ03-1.4 A (NO)
B300, R300, 85°C
RZ03-1.4 A (NO)
12A, 250VAC, 85°C
RZ03-1.4 A (NO)
1/2HP, 125VAC, 85°C
RZ03-1A. A (NO)
1HP, 277VAC, 85°C
Cycles 50x103 10x103 100x103 50x103 30x103 150x103 150x103 50x103 30x103 50x103 150x103 50x103
6x103 100x103
6x103 30x103
Z
F0305-A
Contact ratings for RZ reinforced flux proof version
Type
Contact
Load
IEC 61810
RZ03-1C3-D...-R
A (NO)
16A, 250VAC, 85°C
RZ03-1C3-D...-R
C (CO)
16A, 250VAC, 85°C
RZ01-1C3-D...-R
A (NO)
12A, 250VAC, 85°C
RZ01-1C3-D...-R
C (CO)
12A, 250VAC, 85°C
RZ03-1C4-D...-R
A (NO)
16A, 250VAC, 85°C
RZ03-1C4-D...-R
C (CO)
16A, 250VAC, 85°C
RZ02/3-1C4-D...-R A (NO)
12A, 250VAC, 85°C
RZ02/3-1C4-D...-R C (CO)
12A, 250VAC, 85°C
IEC 60947-5-1
RZ03-1.4
A (NO)
250VAC/6A AC-15
UL 508
RZ03-1C3-D...-R
A (NO)
16A, 277VAC, 85°C
RZ03-1C3-D...-R
C (CO)
16A, 277VAC, 85°C
RZ01-1C3-D...-R
A (NO)
12A, 277VAC, 85°C
RZ01-1C3-D...-R
C (CO)
12A, 277VAC, 85°C
RZ03-1C4-D...-R
A (NO)
16A, 277VAC, 85°C
RZ03-1C4-D...-R
C (CO)
16A, 277VAC, 85°C
RZ02/3-1C4-D...-R A (NO)
12A, 277VAC, 85°C
RZ02/3-1C4-D...-R C (CO)
12A, 277VAC, 85°C
Contact ratings for RZ reflow version
Type
Contact Load
IEC 61810
RZR3-1C4-D...-R
A (NO)
16A, 250Vac, 85°C
RZR1-1C4-D...-R
C (CO)
12A, 250Vac, 85°C
RZR1-1C4-D...-R
A (NO)
12.5A, 400Vac, 85°C
UL 508
RZR3-1C4-D…-R
A (NO)
16A, 277Vac, 85°C
RZR1-1C4-D…-R
C (CO)
12A, 277Vac, 85°C
RZR1-1C4-D…-R
A (NO)
1HP, 277Vac, 85°C
RZR3-1C4-D…-R
A (NO)
1/8 HP, 120Vac, 85°C
Cycles 30x103
6x103 30x103
6x103 30x103
6x103 50x103 20x103
6.050 30x103
6x103 30x103
6x103 30x103
6x103 50x103 20x103 Cycles 30x10³ 20x10³ 50x10³ 30x10³ 30x10³ 30x10³ 100x10³
09-2018, Rev. 0918 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
1
General Purpose Relays PCB Relays
Power PCB Relay RZ (Continued)
SCHRACK
Mechanical endurance
>10x106 operations
Coil Data
Coil voltage range Operative range, IEC 61810 Coil insulation system according UL1446
3 to 48VDC 2
class F
Coil versions, DC coil
Coil
Rated
Operate Release
Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
D003 3 2.1 0.3 22 410
D005 5 3.5 0.5 60 420
D006 6 4.2 0.6 90 400
D009 9 6.3 0.9 200 400
D012 12 8.4 1.2 360 400
D015 15 10.5 1.5 562 410
D024 24 16.8 2.4 1440 400
D048 48 33.6 4.8 5730 400
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Insulation Data
Initial dielectric strength between open contacts between contact and coil Clearance/creepage between contact and coil Material group of insulation parts Tracking index of relay base
1000Vrms 5000Vrms ≥10/10mm
IIIa PTI250V
Othe.