Description General Purpose Relays
Datasheet RZ01-1C4-D048 DatasheetRZ01-1C4-D048 Datasheet (PDF)

General Purpose Relays PCB Relays Power PCB Relay RZ n 1 pole 12/16 A, 1 form C (CO) or 1 form A (NO) contact n DC coil 400 mW n 5kV/10mm coil-contact, reinforced insulation n Ambient temperature 85°C n Product in accordance to IEC 60335-1 n Reflow version for THR mounting process SCHRACK Typical applications Household appliances, boiler control, timers, garage door control, POS automation Approvals VDE Cert. No. 40023970, UL E214025, CQC 12002066685 Technical data of approved types on req.

  RZ01-1C4-D048   RZ01-1C4-D048


Document
General Purpose Relays PCB Relays Power PCB Relay RZ n 1 pole 12/16 A, 1 form C (CO) or 1 form A (NO) contact n DC coil 400 mW n 5kV/10mm coil-contact, reinforced insulation n Ambient temperature 85°C n Product in accordance to IEC 60335-1 n Reflow version for THR mounting process SCHRACK Typical applications Household appliances, boiler control, timers, garage door control, POS automation Approvals VDE Cert. No. 40023970, UL E214025, CQC 12002066685 Technical data of approved types on request Contact Data 12A 16A Contact arrangement 1 form C (CO) or 1 form A (NO) Rated voltage 250VAC Max. switching voltage 400VAC Rated current 12A 16A Limiting making current (form A contact) max. 4s, duty factor 10% 30A max. 20ms (incandescent lamp); AgSnO2 80A Breaking capacity max. 3000VA 4000VA Contact material AgNi 90/10 or AgSnO2 Frequency of operation, with/without load 360/72000h-1 Operate/release time max. 8/6ms Bounce time max., form A/form B 4/10ms Contact ratings for standard version Type Contact Load IEC 61810 RZ03-1A4 A (NO) 16A, 250VAC, 85°C RZ03-1C4 C (CO) 16A, 250VAC, 85°C RZ01-1A3 A (NO) 12A, 250VAC, 85°C RZ01-1A4 A (NO) 12A, 250VAC, 85°C RZ01-1C4 C (CO) 12A, 250VAC, 85°C RZ01/3-1A4 A (NO) 10A, 250VAC, 85°C RZ0H-1A4 A (NO) 12A, 250VAC, 85°C RZ0H-1A4 A (NO) 16A, 250VAC, 85°C RZ0H-1A4 A (NO) 18A, 250VAC, 85°C UL 508 RZ03-1A. A (NO) 16A, 250VAC, 85°C RZ03-1A4 A (NO) 12A, 250VAC, 85°C RZ01-1A3 A (NO) 12A, 250VAC, 85°C RZ03-1.4 A (NO) B300, R300, 85°C RZ03-1.4 A (NO) 12A, 250VAC, 85°C RZ03-1.4 A (NO) 1/2HP, 125VAC, 85°C RZ03-1A. A (NO) 1HP, 277VAC, 85°C Cycles 50x103 10x103 100x103 50x103 30x103 150x103 150x103 50x103 30x103 50x103 150x103 50x103 6x103 100x103 6x103 30x103 Z F0305-A Contact ratings for RZ reinforced flux proof version Type Contact Load IEC 61810 RZ03-1C3-D...-R A (NO) 16A, 250VAC, 85°C RZ03-1C3-D...-R C (CO) 16A, 250VAC, 85°C RZ01-1C3-D...-R A (NO) 12A, 250VAC, 85°C RZ01-1C3-D...-R C (CO) 12A, 250VAC, 85°C RZ03-1C4-D...-R A (NO) 16A, 250VAC, 85°C RZ03-1C4-D...-R C (CO) 16A, 250VAC, 85°C RZ02/3-1C4-D...-R A (NO) 12A, 250VAC, 85°C RZ02/3-1C4-D...-R C (CO) 12A, 250VAC, 85°C IEC 60947-5-1 RZ03-1.4 A (NO) 250VAC/6A AC-15 UL 508 RZ03-1C3-D...-R A (NO) 16A, 277VAC, 85°C RZ03-1C3-D...-R C (CO) 16A, 277VAC, 85°C RZ01-1C3-D...-R A (NO) 12A, 277VAC, 85°C RZ01-1C3-D...-R C (CO) 12A, 277VAC, 85°C RZ03-1C4-D...-R A (NO) 16A, 277VAC, 85°C RZ03-1C4-D...-R C (CO) 16A, 277VAC, 85°C RZ02/3-1C4-D...-R A (NO) 12A, 277VAC, 85°C RZ02/3-1C4-D...-R C (CO) 12A, 277VAC, 85°C Contact ratings for RZ reflow version Type Contact Load IEC 61810 RZR3-1C4-D...-R A (NO) 16A, 250Vac, 85°C RZR1-1C4-D...-R C (CO) 12A, 250Vac, 85°C RZR1-1C4-D...-R A (NO) 12.5A, 400Vac, 85°C UL 508 RZR3-1C4-D…-R A (NO) 16A, 277Vac, 85°C RZR1-1C4-D…-R C (CO) 12A, 277Vac, 85°C RZR1-1C4-D…-R A (NO) 1HP, 277Vac, 85°C RZR3-1C4-D…-R A (NO) 1/8 HP, 120Vac, 85°C Cycles 30x103 6x103 30x103 6x103 30x103 6x103 50x103 20x103 6.050 30x103 6x103 30x103 6x103 30x103 6x103 50x103 20x103 Cycles 30x10³ 20x10³ 50x10³ 30x10³ 30x10³ 30x10³ 100x10³ 09-2018, Rev. 0918 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 1 General Purpose Relays PCB Relays Power PCB Relay RZ (Continued) SCHRACK Mechanical endurance >10x106 operations Coil Data Coil voltage range Operative range, IEC 61810 Coil insulation system according UL1446 3 to 48VDC 2 class F Coil versions, DC coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ω±10% mW D003 3 2.1 0.3 22 410 D005 5 3.5 0.5 60 420 D006 6 4.2 0.6 90 400 D009 9 6.3 0.9 200 400 D012 12 8.4 1.2 360 400 D015 15 10.5 1.5 562 410 D024 24 16.8 2.4 1440 400 D048 48 33.6 4.8 5730 400 All figures are given for coil without pre-energization, at ambient temperature +23°C. Other coil voltages on request. Insulation Data Initial dielectric strength between open contacts between contact and coil Clearance/creepage between contact and coil Material group of insulation parts Tracking index of relay base 1000Vrms 5000Vrms ≥10/10mm IIIa PTI250V Othe.


RZ01-1C4-D024 RZ01-1C4-D048 RZ03-1A3-D005


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)