PT270L24 Datasheet: General Purpose Relays





PT270L24 General Purpose Relays Datasheet

Part Number PT270L24
Description General Purpose Relays
Manufacture TE
Total Page 4 Pages
PDF Download Download PT270L24 Datasheet PDF

Features: General Purpose Relays Industrial Relays Miniature Relay PT n 2 pole 12A, 3 pol e 10A or 4 pole 6A, 2, 3 or 4 form C (C O) contacts n DC or AC coil n Switching performance up to 3000VA n Relay heigh t 29mm n Mechanical indicator, optional LED and protection diode n Manual test tab, optionally lockable n White marki ng tabs SCHRACK Typical applications Universal use in control and automation F0191-B Approvals VDE Cert. No. 40 009108, UL E214025, Lloyds 00/20059 Tec hnical data of approved types on reques t Contact Data PT2 PT3 PT5 C ontact arrangement 2 form C 3 form C 4 form C 2 CO 3 CO 4 CO Ra ted voltage 240VAC Max. switchin g voltage 400VAC 400VAC 240VAC Rat ed current 12A 10A 6A Limiting making current, max. 20ms 24A 20A 12A Limiting breaking current 12A 10A 6A Limiting short-time current 300A/30ms Switching power 3000 VA 2500VA 1500VA Contact material A gNi90/10, AgNi90/10 gold plated Min. recommended contact load.

Keywords: PT270L24, datasheet, pdf, TE, General, Purpose, Relays, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute, Equivalent

General Purpose Relays
Industrial Relays
Miniature Relay PT
n 2 pole 12A, 3 pole 10A or 4 pole 6A, 2, 3 or 4 form C (CO) contacts
n DC or AC coil
n Switching performance up to 3000VA
n Relay height 29mm
n Mechanical indicator, optional LED and protection diode
n Manual test tab, optionally lockable
n White marking tabs
SCHRACK
Typical applications
Universal use in control and automation
F0191-B
Approvals
VDE Cert. No. 40009108, UL E214025, Lloyds 00/20059
Technical data of approved types on request
Contact Data
PT2
PT3
PT5
Contact arrangement
2 form C 3 form C 4 form C
2 CO
3 CO
4 CO
Rated voltage
240VAC
Max. switching voltage
400VAC 400VAC 240VAC
Rated current
12A
10A
6A
Limiting making current, max. 20ms 24A
20A
12A
Limiting breaking current
12A
10A
6A
Limiting short-time current
300A/30ms
Switching power
3000VA 2500VA 1500VA
Contact material AgNi90/10, AgNi90/10 gold plated
Min. recommended contact load
12V at 10mA
gold plated: 20mV at 1mA
Initial voltage drop 30mV at 100mA/6VDC
Frequency of operation
with/without load
360/36000h-1
Operate time typ., DC coil
15ms
Release time typ., DC coil, without/with PD
10/18ms
Bounce time typ., DC coil, form A/form B
6/8ms
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
PT 2 DC/AC coil C (CO)
12A, 250VAC, cosφ=1, 70°C 70x103
PT 2 DC/AC coil A (NO) of C (CO) 9A, 250VAC, cosφ=1, 80°C 150x103
PT 2 DC/AC coil A (NO) of C (CO) 4A, 250VAC, cosφ=1, 80°C 300x103
PT 3 DC/AC coil C (CO)
10A, 250VAC, cosφ=1, 70°C 100x103
PT 5 DC/AC coil C (CO)
6A, 250VAC, cosφ=1, 70°C 100x103
Z
Contact Data (continued)
Contact ratings
Type Contact
Load
Cycles
UL 508
PT 2 C (CO)
12A, 250VAC, general purpose, 70°C 6.000
PT 2 C (CO)
12A, 250VAC, resistive, 70°C
100x103
PT 2 A (NO) of C (CO) 12A, 250VAC, resistive, 70°C
100x103
PT 2 A (NO) of C (CO) 12A, 250VAC, resistive, 70°C
100x103
PT 3 C (CO)
10A, 250VAC, general purpose, 70°C 6.000
PT 3 C (CO)
10A, 250VAC, resistive, 70°C
100x103
PT 3 A (NO) of C (CO) 10A, 250VAC, resistive, 70°C
100x103
PT 3 B (NC) of C (CO) 10A, 250VAC, resistive, 70°C
100x103
PT 5 C (CO)
6A, 250VAC, general purpose, 70°C
6.000
PT 5 C (CO)
6A, 250VAC, resistive, 70°C
100x103
PT 5 A (NO) of C (CO) 6A, 250VAC, resistive, 70°C
100x103
PT 5 B (NC) of C (CO) 6A, 250VAC, resistive, 70°C
100x103
EN60947-4-1
PT 2 A (NO) of C (CO) 400VAC, 3.75A, AC3, opposite polarity, 70°C
PT 2 A (NO) of C (CO) 230VAC, 1.7A, AC5b (400W lamp load),
opposite polarity, 70°C
PT 3 A (NO) of C (CO) 250VAC, 2A, AC3, opposite polarity 70°C
PT 3 A (NO) of C (CO) 230VAC, 1.7A, AC5b (400W lamp load),
opposite polarity, 70°C
PT 5 A (NO) of C (CO) 250VAC, 3A, AC3, same polarity 70°C
PT 5 A (NO) of C (CO) 230VAC, 1.7A, AC5b (400W lamp load),
same polarity, 70°C
PT 2 A (NO) of C (CO) DC coil, AC-15, 250VAC/4A, opposite polarity
6.050
PT 3 A (NO) of C (CO) DC coil, AC-15, 250VAC/4A, same polarity 6.050
PT 5 A (NO) of C (CO) DC coil, AC-15, 250VAC/4A, same polarity 6.050
PT 2 A (NO) of C (CO) AC coil, AC-15, 250VAC/2A, opposite polarity
6.050
PT 3 A (NO) of C (CO) AC coil, AC-15, 250VAC/2A, same polarity 6.050
PT 5 A (NO) of C (CO) AC coil, AC-15, 250VAC/2A, same polarity 6.050
PT2/3/5 A (NO) of C (CO) DC-13, 24VDC/4A 6.050
Mechanical endurance
DC coil
30x106 operations
AC coil
20x106 operations
Coil Data
Coil voltage range
Operative range, IEC 61810
DC coil, AC-coil 50Hz
AC coil 60 Hz at 70°C
Coil insulation system according UL
6 to 220VDC
6 to 230VAC
2
90..110% of rated voltage
class 155 (F)
01-2017, Rev. 0117
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1

           






Index : 0  1  2  3   4  5  6  7   8  9  A  B   C  D  E  F   G  H  I  J   K  L  M  N   O  P  Q  R   S  T  U  V   W  X  Y  Z
@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)