General Purpose Relays Force Guided Relays
Force Guided Relay SR6 A/B/C/V
n 6 pole relay with force guided contacts according to EN 50205 n Reinforced insulation between all contacts
SCHRACK
Typical applications Emergency shut-off, press control, machine control, elevator and escalator control, safety relays
F0206-EA
Approvals
VDE Cert. No. 128935, UL E214025, TUV 968/EL 350, CCC 2012010304537809
Technical data of approved types on request
Contact Data
Contact arrangement 3 form A + 3 form B contacts
3 NO + 3 NC,
4 form A + 2 form B contacts
4 NO + 2 NC,
5 form A + 1 form B contacts
5 NO + 1 NC
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A
Contact material
AgSnO2,
AgSnO2 + 0.2μm Au
Contact style single contact, force guided
type A according to EN 50205
Min. recommended contact load
5V, 10mA
Initial contact resistance ≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/150min-1
Contact ratings, IEC60947-5-1,
on 2 form A (NO) contact
AC15-5A
DC13-6A
Mechanical endurance
10x106 operations
Z
Coil Data
Coil voltage range Max. coil power
5 to 110VDC 1200mW or 800mW
Coil versions, DC-coil 800mW
Coil
Rated
Operate Release
Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW K12 12 9 1.2 180 800
K15 15 11.3 1.5 281 801 K18 18 13.5 1.8 405 800
K21 21 16 2.1 551 800
K24 24 18 2.4 720 800
K36 36 27 3.6 1620 800
K48 48 36
4.8
28801) 800
L10 110 82.5 11.0 151301) 800
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil versions, DC-coil 1200mW
Coil
Rated
Operate Release
Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10%1) mW
005 5 3.8 0.5 21 1190
006 6 4.5 0.6 30 1200
009 9 6.8 0.9 68 1191
012
12
9
1.2
120
1200
018 18 13.5 1.8 270 1200
021 21 16 2.1 368 1198
024 24 18 2.4 480 1200
036 36 27
3.6
1080
1200
040 40 30
4.0
1333
1200
048 48 36
4.8
1920
1200
060 60 45
6.0 30001) 1200
110
110
83
11.0
100801) 1200
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
06-2017, Rev. 0617 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
1
General Purpose Relays Force Guided Relays
Force Guided Relay SR6 A/B/C/V (Continued)
SCHRACK
Insulation Data
Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between open contacts between contact and coil between adjacent contacts Insulation to EN 50178, type of insulation between contact and coil between adjacent contacts
1500Vrms 4000Vrms 3000Vrms microdisconnection ≥5.5/5.5mm ≥5.5/5.5mm reinforced reinforced
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-25 to 70°C
Category of environmental Protection
IEC 61 810
RTIII1)
1) See product specification 2158003 4.6 and 4.8.
Weight 30g
Resistance to soldering heat THT
IEC 60068-2-20
260°C/5s
Packaging/unit
tube/10 pcs.
For more detailed information see product specification 2158003
Dimensions SR6 A/B/C
SR6 V
PCB layout / terminal assignment
Bottom view
3 form A + 3 form B, 3 NO + 3 NC versions SR6 A
S0367-DN
S0367-DU
4 form A + 2 form B, 4 NO + 2 NC versions SR6 B
5 form A + 1 form B, 5 NO + 1 NC versions SR6 C
S0368-CA
S0368-CA
S0368-CE
S0368-CC
S0368-CB
S0368-CD
4 form A + 2 form B, 4 NO + 2 NC versions SR6 V
The design of the SR6 V allows clearance/creepage of 5.5 mm on the PCB.
2
06-2017, Rev. 0617 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
S0368-CU
S0368-CV
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
General Purpose Relays Force Guided Re.