Document
General Purpose Relays Force Guided Relays
Force Guided Relay SR4 D/M
n 4 pole relay with force guided contacts according to EN 50205 n Compact design and space efficient
SCHRACK
Typical applications Emergency shut-off, press control, machine control, elevator and escalator control, safety relays
Approvals
VDE Cert. No. 40005334, UL E214025, TUV 968/EL 230, CCC 2012010304537809
Technical data of approved types on request
Contact Data
Contact arrangement 3 form A + 1 form B contacts
3 NO + 1 NC
2 form A + 2 form B contacts
2 NO + 2 NC
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A
Contact material
AgSnO2
Contact style single contact, force guided
type A according to EN 50205
Min. recommended contact load
5V/10mA
Initial contact resistance ≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/150min-1
Contact ratings, IEC60947-5-1,
on 1 form A (NO) contact
AC15-3A
DC13-3A
Mechanical endurance
10x106 operations
ZT
F0244-C
Coil data (continued)
Coil versions, DC-coil
Coil
Rated
Operate Release
Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
015 15 11.3 1.5 281 801
018 18 13.5 1.8 405 800
021 21 16.0 2.1 551 800
024 24 18.0 2.4 720 800
036 36 27.0 3.6 1620 800
040 40 30.0 4.0 2000 800
048 48 36.0 4.8 2880 800
060 60 45.0 6.0 4500 800
085 85 63.8 8.5 9031 800
110 110 83.0 11.0 15125 800
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil data
Coil voltage range
5 to 110VDC
Coil versions, DC-coil
Coil
Rated
Operate Release
Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
005 5 3.8 0.5 31 806
006 6 4.5 0.6 45 800
009 9 6.8 0.9 101 802
012 12 9.0 1.2 180 800
Insulation Data
Initial dielectric strength
between open contacts
1500Vrms
between contact and coil
4000Vrms
between adjacent contacts
2500Vrms
Clearance/creepage
between open contacts
microdisconnection
between contact and coil
≥10/10mm
between adjacent contacts
≥3/3.5mm
Insulation to EN 50178, type of insulation
between contact and coil
reinforced
between adjacent contacts
basic
04-2015, Rev. 0415 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
1
General Purpose Relays Force Guided Relays
Force Guided Relay SR4 D/M (Continued)
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-25 to 70°C
Category of environmental Protection
IEC 61 810
RTIII
Weight 30g
Resistance to soldering heat THT
IEC 60068-2-20
260°C/5s
Packaging/unit
tube/10 pcs.
PCB layout / terminal assignment
Bottom view on solder pins
For more detailed information see product specification 2158002
2 form A + 2 form B, 2 NO + 2 NC contacts
SCHRACK
S0413-BC
Dimensions
3 form A + 1 form B, 3 NO + 1 NC contacts
S0413-BB
S0412-BH
S0413-BA
Product code structure
Type SR4 Relay with force guided contacts SR4 Contact arrangement D 2 form A + 2 form B contacts (2 NO + 2 NC) M 3 form A + 1 form B contacts (3 NO + 1 NC) Contact material 4 AgSnO2 Coil Coil code: please refer to coil versions table (e.g. 012=12VDC)
Other types on request
Typical product code SR4 D 4 012
2
04-2015, Rev. 0415 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company
Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section.
Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change.
General Purpose Relays Force Guided Relays
Force Guided Relay SR4 D/M (Continued)
SCHRACK
Product code
Type
Contact arrangement Contact material
Coil
Part number
SR4D4005 SR4D4006
4 pole relay with
2 form A + 2 form B,
AgSnO2 5VDC 7-1415054-1
2 NO + 2 NC
6VDC
8-1415054-1
SR4D4009
force guided contacts
contacts
9VDC
9-1415054-1
SR4D4012 12VDC 1415055-1
SR4D4018 18VDC 1-1415055-1
SR4D4021 21VDC 2-1415055-1
SR4D4024 24VDC 3-14.