Description General Purpose Panel/Plug-in Relays
Datasheet MT3230C4 DatasheetMT3230C4 Datasheet (PDF)

General Purpose Panel/Plug-in Relays Multimode Relay MT n 2/3 pole 10A, 2 form C (CO) or 3 form C (CO) contacts n DC and AC coils n Mechanical indicator as standard n Electrical indicator n New test system with front operated finger protected push-to-test button and integral locking test tab n White write on panel SCHRACK Typical applications Mechanical engineering, plant control. Approvals VDE Cert. No. 40009096, UL E214025 Technical data of approved types on request. Contact Data Cont.

  MT3230C4   MT3230C4


Document
General Purpose Panel/Plug-in Relays Multimode Relay MT n 2/3 pole 10A, 2 form C (CO) or 3 form C (CO) contacts n DC and AC coils n Mechanical indicator as standard n Electrical indicator n New test system with front operated finger protected push-to-test button and integral locking test tab n White write on panel SCHRACK Typical applications Mechanical engineering, plant control. Approvals VDE Cert. No. 40009096, UL E214025 Technical data of approved types on request. Contact Data Contact arrangement 2 form C (CO) or 3 form C (CO) Rated voltage 240VAC Max. switching voltage 400VAC Rated current 10A 10A Limiting making current, max. 20ms 20A 20A Limiting breaking current 10A 10A Switching power 2500VA 2500VA Contact material AgNi90/10 AgNi90/10 - gold plated Contact style single single contact contact Min. recommended contact load 12V 20mV at 10mA at 1mA Initial voltage drop 30mV at 100mA/6VAC/1kHz Frequency of operation, with/without load 1200/6000h-1 Operate time typ, DC coil 15ms Release time typ, DC coil 10ms Bounce time max., DC coil, form A/form B 4/10ms Contact ratings Type Contact Load IEC 61810 MT22 DC coil C (CO) 10A, 250VAC, cosφ=1, 35°C MT22 AC coil C (CO) 10A, 250VAC, cosφ=1, 35°C MT32 DC coil C (CO) 10A, 250VAC, cosφ=1, 35°C MT32 AC coil C (CO) 10A, 250VAC, cosφ=1, 35°C UL 508 MT3 A (NO)/B (NC) B300, 40°C MT2 C (CO) 10A, 250VAC, resistive, 40° MT2 A (NO)/B (NC) B300 40°C MT3 C (CO) 10A, 250VAC, resistive, 40°C Cycles 100x103 20x103 100x103 20x103 6.000 30x103 6.000 100x103 Z Contact Data (continued) Mechanical endurance DC coil AC coil Coil Data Coil voltage range Operative range, IEC 61810 Coil insulation system according UL 20x106 operations 20x106 operations 6 to 220VDC 12 to 230VAC 2 class 130 (B) Coil versions, DC coil Coil code Rated Operate Release Coil Rated coil STD PD3) voltage voltage voltage resistance power VDC VDC VDC Ω±10%1)2) W 006 0A6 6 4.5 0.6 30 1.1 012 0B2 12 9.0 1.2 115 1.3 024 0C4 24 18.0 2.4 475 1.2 048 0E8 48 36.0 4.8 1900 1.2 060 0G0 60 45.0 6.0 2950 1.3 110 1B0 110 82.5 11.5 97001) 1.2 220 2C0 220 165.0 22.0 387002) 1.2 1) Coil resistance ±12%, 2) Coil resistance ±15%. 3) Protection diode PD; standard polarity: 2-pole relays: +2 / -7, 3-pole relays: +2 / -10. All figures are given for coil without pre-energization, at ambient temperature +23°C. Coil versions, AC coil, 50/60Hz Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power 50/60Hz 50/60Hz 50/60Hz VAC VAC VAC Ω±10%1) VA 012 12 9.6/10.2 3.6 24 2.19/1.86 024 24 19.2/20.4 7.2 86 2.26/1.95 048 48 38.4/40.8 14.4 345 2.28/1.97 060 60 48.0/51.0 18.0 544 2.27/1.96 115 115 92.0/97.8 34.5 2000 2.37/2.00 230 230 184.0/195.5 69.0 83001) 2.32/1.96 1) Coil resistance ±12%. All figures are given for coil without pre-energization, at ambient temperature +23°C. 05-2019, Rev. 0219 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change. 1 General Purpose Panel/Plug-in Relays Multimode Relay MT (Continued) SCHRACK Insulation Data Initial dielectric strength between open contacts 1500Vrms between contact and coil 2500Vrms between adjacent contacts 2500Vrms Clearance/creepage between contact and coil ≥2.8/4mm between adjacent contacts ≥2.8/4mm Material group of insulation parts IIIa Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature DC coil -40 to +60°C AC coil -40 to +50°C Category of environmental protection IEC 61810 RTI - dust protected Vibration resistance (functional), form A (NO)/form B (NC) 5/2g Terminal type plug-in Cover retention, pull/push force 100/100N Weight 80g Packaging unit 25 pcs. Accessories For details see datasheet Accessories Multimode Relay MT Note: indicated contact ratings and electrical endurance data for direct wiring of relays (according IEC 61810-1); for relays mounted on sockets deratings may apply. Terminal assignment Bottom view on pins Dimensions 2 05-2019, Rev. 0219 www.t.


MT323024 MT3230C4 MT326012


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)