Document
DC/DC Converters
TEN 10 Series, 10 Watt
Features ◆ Wide 2:1 input range ◆ High power density
not recommended for new design in
UL 60950-1
◆ Operating temperature range
–40°C to +85°C
◆ Indefinite short circuit protection
◆ I/O isolation 1500 VDC
◆ Input filter to meet EN 55022, Class A
and FCC, level A without external components
◆ Industry standard pinout
◆ Shielded metal case with insulated
baseplate
◆ High reliability, MTBF >1 Mio. h ◆ 3-year product warranty
The TEN 10 series is a family of high performance 10W DC/DC converters in a compact 2” x 1” low profile package with industry standard footprint. A high efficiency allows a wide operating temperature range of –40°C to +85°C. A built-in EMI filter is built in to meet EN 55022, class A without any external components. Further standard features include over voltage protection and short-circuit protection. Typical applications for these converters are battery operated equipment, instrumentation, distributed power architectures in communication and industrial electronics, everywhere where isolated, tightly regulated voltages are required.
Models
Order code TEN 10-1210 TEN 10-1211 TEN 10-1212 TEN 10-1213 TEN 10-1215 TEN 10-1221 TEN 10-1222 TEN 10-1223 TEN 10-2410 TEN 10-2411 TEN 10-2412 TEN 10-2413 TEN 10-2415 TEN 10-2421 TEN 10-2422 TEN 10-2423 TEN 10-4810 TEN 10-4811 TEN 10-4812 TEN 10-4813 TEN 10-4815 TEN 10-4821 TEN 10-4822 TEN 10-4823
Input voltage range
9 – 18 VDC (12 VDC nominal)
18 – 36 VDC (24 VDC nominal)
36 – 75 VDC (48 VDC nomial)
Output voltage 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC ±5 VDC ±12 VDC ±15 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC ±5 VDC ±12 VDC ±15 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC ±5 VDC ±12 VDC ±15 VDC
http://www.tracopower.com
Output current max. 2’400 mA 2‘000 mA 830 mA 670 mA 415 mA ±1‘000 mA ±415 mA ±330 mA 2’400 mA 2‘000 mA 830 mA 670 mA 415 mA ±1‘000 mA ±415 mA ±330 mA 2‘400 mA 2‘000 mA 830 mA 670 mA 415 mA ±1‘000 mA ±415 mA ±330 mA
Efficiency typ. 72 % 77 % 80 % 80 % 81 % 78 % 81 % 80 % 76 % 78 % 82 % 82 % 83 % 80 % 82 % 82 % 76 % 80 % 82 % 83 % 83 % 81 % 83 % 83 %
Page 1 of 4
DC/DC Converters
TEN 10 Series 10 Watt
Input Specifications
Input current at no load
12 Vin models: 30 mA typ. 24 Vin models: 20 mA typ. 48 Vin models: 10 mA typ.
Input current at full load
12 Vin; 3.3 VDC models: 915 mA typ.
12 Vin; 5 & ±5 VDC models: 1080 mA typ.
12 Vin; other output models: 1045 mA typ.
24 Vin; 3.3 VDC models: 435 mA typ.
24 Vin; 5 & ±5 VDC models: 530 mA typ.
24 Vin; other output models: 510 mA typ.
48 Vin; 3.3 VDC models: 215 mA typ.
48 Vin; 5 & ±5 VDC models: 260 mA typ.
48 Vin; other output models: 250 mA typ.
Start-up voltage / under voltage shut down
12 Vin models: 8.5 VDC / 8 VDC 24 Vin models: 16.5 VDC / 16 VDC 48 Vin models: 32.5 VDC / 32 VDC
Surge voltage (1 sec. max.)
12 Vin models: 25 V max. 24 Vin models: 50 V max. 48 Vin models: 100 V max.
Reserve voltage protection 1.0 A max.
Conducted noise (input) EN 55022 level A, FCC part 15, level A
Output Specifications
Voltage set accuracy ±1 %
Regulation
– Input variation Vin min. to Vin max. 0.3 % max.
– Load variation 10 % – 90 % single output models: 0.5 % max.
dual output models: 1 % max. (balanced load)
dual output models: 3 % max. (unbalanced load)
Ripple and noise (20 MHz Bandwidth)
single output models: 50 mVpk-pk max.
dual output models: 75 mVpk-pk max.
Temperature coefficient ±0.02 %/K
Output current limitation >110 % of lout max., constant current
Short circuit protection continuous (automatic recovery)
Capacitive load
single output models: 2200 µF max.
dual output models: 470 µF max.
General Specifications
Temperature ranges
– Operating –40°C to +85°C – Case temperature +100°C max. – Storage –40°C to +125°C
Derating (convection cooling) 3.3 %/K above 70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >1 Mio h
Isolation Test Voltage (Input/Output, 60s) 1‘500 VDC
Insulation System Functional
Isolation Capacitance (Input/Output) 150 pF typ.
Isolation Resistance (Input/Output) >1 G Ohm
Switching Frequency
single output models: 500 kHz typ. (pulse width modulation)
dual output models: 300 kHz typ. (pulse width modulation)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com
Page 2 of 4
DC/DC Converters
TEN 10 Series 10 Watt
General Specifications
EMC immunity
– Electrostatic discharge ESD EN 61000-4-2 – RF field susceptibility EN 61000-4-3 – Electrical fast transien.