Description Power Relay
Datasheet V23076-A1001-D143 DatasheetV23076-A1001-D143 Datasheet (PDF)

Automotive Relays PCB Single Relays Power Relay K (Open – Sealed) n Limiting continuous current 45A n Wide voltage range n 24VDC coil versions available n For high current version refer to Power Relay K-S Typical applications ABS control, blower fans, car alarm, cooling fan, engine control, fuel pump, hazard warning signal, heated front screen, heated rear screen, ignition, lamps front/rear/fog light, interior lights, main switch/supply relay, seat control, seatbelt pretensioner, sun roof, turn.

  V23076-A1001-D143   V23076-A1001-D143



Document
Automotive Relays PCB Single Relays Power Relay K (Open – Sealed) n Limiting continuous current 45A n Wide voltage range n 24VDC coil versions available n For high current version refer to Power Relay K-S Typical applications ABS control, blower fans, car alarm, cooling fan, engine control, fuel pump, hazard warning signal, heated front screen, heated rear screen, ignition, lamps front/rear/fog light, interior lights, main switch/supply relay, seat control, seatbelt pretensioner, sun roof, turn signal, valves, window lifter, wiper control. Contact Data Typical applications Resistive/inductive Resistive/inductive Indicator lamps Headlights, Headlights loads loads capacitive loads capacitive loads Contact arrangement 1 form A, 1 NO 1 form C, 1 CO 1 form A, 1 NO 1 form A, 1 NO 1 form C, 1 CO Rated voltage 12VDC 12VDC 12VDC 12VDC 12VDC A/B (NO/NC) A/B (NO/NC) Rated current 45A 45/30A 30A 40A 40/25A Limiting continuous current 23°C 45A 45/30A 30A 40A 40/25A 85°C 30A 30/25A 25A 25A 25/20A Limiting making current1) 100A 100/30A 120A3) 180A 180/60A Limiting breaking current2) 60A 60/30A 60A 60A 60/30A Contact material AgNi0.15 AgNi0.15 AgSnO2 AgSnO2 AgSnO2 Min. recommended contact load 1A at 5VDC4) Initial voltage drop, at 10A, typ./max. 20/300mV Operate/release time typ. 5/3ms5) Electrical endurance >2x105 ops. >2x105 ops. >2.2x106 ops. >105 ops. >105 ops. at 13.5VDC, 40A at 13.5VDC, 40A up to 8x21W up to 4x60W up to 4x60W Mechanical endurance, DC coil >107 ops. 1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5VDC for 12VDC or 27VDC for 24VDC load voltages. 2) For a load current duration of maximum 3s for a make/break ratio of 1:10. 3) Corresponds to a peak inrush current on initial actuation (cold filament). 4) See chapter Diagnostics of Relays in our Application Notes or consult the internet at http://relays.te.com/appnotes/ 5) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding. Max. DC load breaking capacity TE0556-E Load limit curve 1: arc extinguishes, during transit time (changeover contact). Load limit curve 2: safe shutdown, no stationary arc (make contact). Load limit curves measured with low inductive resistors verified for 1000 switching events. 11-2013, Rev. 1113 www.te.com © 2013 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Catalog product data, ‘Definitions’ sectio.


V23076-A1001-C133 V23076-A1001-D143 V23076-A3001-C132


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)