DC/DC Converter. RK-0515S-H6 Datasheet

RK-0515S-H6 Converter. Datasheet pdf. Equivalent

RK-0515S-H6 Datasheet
Recommendation RK-0515S-H6 Datasheet
Part RK-0515S-H6
Description DC/DC Converter
Feature RK-0515S-H6; Features Unregulated Converters • High 6.4kVDC/1s isolation • Wide operating temperature range fr.
Manufacture RECOM
Datasheet
Download RK-0515S-H6 Datasheet





RECOM RK-0515S-H6
Features
Unregulated
Converters
• High 6.4kVDC/1s isolation
• Wide operating temperature range from
-40°C to +90°C without derating
• High capacitive load capability
• Continuous short circuit protection
• Efficiency up to 80%
DC/DC Converter
RK/H6 & RH/H6
Description
The RK/H6 and RH/H6 series 1W DC/DC converters feature high 6.4kVDC isolation and an extended
operating temperature range up to +90°C without derating, yet are lower cost than standard high
isolation converters. They are suitable for demanding industrial and high isolation test and measurement
applications.
Selection Guide
Part
Number
RK-xx3.3S/H6
RK-xx05S/H6
RK-xx12S/H6
RK-xx15S/H6
RH-xx3.3D/H6
RH-xx05D/H6
RH-xx12D/H6
RH-xx15D/H6
nom. Input
Output
Output Efficiency Max. Capacitive
Voltage Range Voltage
Current
typ.
Load (1)
[VDC] [VDC] [mA] [%] [µF]
5, 12, 15, 24
3.3
303 71-74
1000
5, 12, 15, 24
5
200 74-77
1000
5, 12, 15, 24
12
84 77-79
220
5, 12, 15, 24
15
66 77-80
220
5, 12, 15, 24
±3.3
±152
73-74
±330
5, 12, 15, 24
±5
±100
74-77
±330
5, 12, 15, 24
±12
±42 77-80
±100
5, 12, 15, 24
±15
±33 78-80
±100
Notes:
Note1: Max. capacitive load is tested at nominal input voltage and full load
1 Watt
SIP7
Single and Dual
Output
Model Numbering
RK- __ __ S/H6
Input Voltage
6.4kVDC isolation
Output Voltage
Single
RH- __ __ D/H6
Input Voltage
6.4kVDC isolation
Output Voltage
Dual
E224736
UL60950-1 certified
CAN/CSA C22.2 No. 60950-1-07 certified
UL62368-1 certified
CAN/CSA C22.2 No. 62368-1-14 certified
IEC/EN60950-1 certified
IEC/EN62368-1 certified
CB report
Notes:
Note2: add suffix „K“ for Single output or suffix „H“ for Dual output
Ordering Examples:
RK-123.3S/H6 = 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output, 6.4kVDC/1s isolation
RH-0505D/H6 = 5VDC Input Voltage, 5VDC Output Voltage, Dual Output, 6.4kVDC/1s isolation
www.recom-power.com
REV.: 5/2019
ECO-1



RECOM RK-0515S-H6
RK/H6 & RH/H6
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Internal Input Filter
Input Voltage Range
Start-up Time
Internal Operating Frequency
Minimum Load
Output Ripple and Noise
Efficiency vs. Load
Single Output
Condition
20MHz BW
Min. Typ.
±10%
20ms
80kHz
0%
60mVp-p
Dual Output
Max.
capacitor
120mVp-p
100
90
80
70
60
50
40
30
20
10
0
0
RK-123.3S/H6
RK-0505S/H6
RK-0512S/H6
RK-2415S/H6
10 20 30 40 50 60 70 80
Output Load [%]
90 100
100
90
80
70
60
50
40
30
20
10
0
0
RH-123.3D/H6
RH-0505D/H6
RH-1212D/H6
RH-0515D/H6
10 20 30 40 50 60 70
Output Load [%]
80 90 100
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation (3)
Condition
low line to high line, max. load
10% to 100% load
Notes:
Note3: Operation below 10% load will not harm the converter, but specifications may not be met
Values
±5.0% max.
±1.2% of 1.0% Vin typ.
10% max.
Deviation vs. Load
20
Single Output
Dual Output
20
15 15
10 10
55
00
-5
-10
-15
-20
0
RK-123.3S/H6
RK-0505S/H6
RK-0512S/H6
RK-2415S/H6
10 20 30 40 50 60 70 80 90 100
Output Load [%]
-5
-10
-15
-20
0
RH-123.3D/H6
RH-0505D/H6
RH-1212D/H6
RH-0515D/H6
10 20 30 40 50 60 70 80 90 100
Output Load [%]
www.recom-power.com
REV.: 5/2019
ECO-2



RECOM RK-0515S-H6
RK/H6 & RH/H6
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
PROTECTIONS
Parameter
Short Circuit Protection (SCP)
Isolation Voltage (4)
Isolation Resistance
Isolation Capacitance
Insulation Grade
Condition
I/P to O/P
tested for 1 second
rated for 1 minute
Notes:
Note4: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note5: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
Value
continuous
6.4kVDC
5.2kVDC
10Gmin.
75pF max.
functional
ENVIRONMENTAL
Parameter
Operating Temperature Range
Operating Altitude
Operating Humidity
MTBF
Derating Graph
Condition
without derating @ free air convection (see graph)
non-condensing
according to MIL-HDBK-217F; G.B.
+25°C
+85°C
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
Ambient Temperature [°C]
95
Value
-40°C to +90°C
5000m
5% - 95% RH max.
14919 x 10³ hours
9468 x 10³ hours
SAFETY AND CERTIFICATIONS
Certificate Type
Information Technology Equipment - General Requirements for Safety
Audio/Video, information and communication technology equipment -
Part1: Safety requirements
Information Technology Equipment, General Requirements for Safety (CB)
Information Technology Equipment, General Requirements for Safety
Audio/video, information and communication technology equipment Part
1: safety requirements (CB)
Audio/video, information and communication technology equipment Part
1: safety requirements
Report / File Number
E224736-A25-UL
E224736-A26-CB-1
OFF-4787079973-A-2
Standard
UL60950-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edtition, 2014
UL62368-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 62368-1-14, 2nd Edtition, 2014
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
IEC62368-1:2014, 2nd Edition
EN62368-1:2014
www.recom-power.com
continued on next page
REV.: 5/2019
ECO-3