HAC60D150 Mount Datasheet

HAC60D150 Datasheet PDF, Equivalent


Part Number

HAC60D150

Description

Panel Mount

Manufacture

Crydom

Total Page 7 Pages
PDF Download
Download HAC60D150 Datasheet PDF


HAC60D150
DatasPahneleMeoutnt
HAC Series
Load Voltage range 24 to 660 VAC
Output rating up to 150 Arms
Zero Voltage or Instantaneous Turn-on options
AC or DC input control options
Locking Input Connector
Optional Transient Protection & installed Thermal Pad
PRODUCT SELECTION
Control Voltage
3-32 VDC
90-140 VAC
150-270 VAC
AVAILABLE OPTIONS
Series
HAC
150 A
HAC24D150 ,HAC60D150
HAC24B150 ,HAC60B150
HAC24A150 ,HAC60A150
Control Voltage
A: 150-270 VAC
B: 90-140 VAC
D: 4-32 VDC
Overvoltage Protection
Blank: Not Included
P: Included (6)
Switching Type
Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On (5)
24 A 150 P H -10
Operating Voltage
24: 24-280 VAC
60: 48-660 VAC
Rated Load Current
150: 150 Amps
Thermal Pad
Blank: Not Included
H: Included
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum Off-State dv/dt @ Maximum Rated Voltage [V/µSec]
Maximum Load Current [Arms](2)
Minimum Load Current [Arms]
Maximum Surge Current [Apk] 1 Cycle 50/60 Hz
Maximum I²t for fusing (10msec)/(8.33msec)[A²sec]
Maximum On-State Voltage Drop @ Rated Current [Vrms]
Thermal Resistance Juncti on to Case (Rjc) [°C/W]
Minimum Power Factor (with Maximum load)
Wire Size max (solid/stranded) [AWG/ IEC mm²] (3)
Output Terminal Nut Torque Range [in lb (Nm)
HP Rating UL 508/IEC60957 [HP (KW)]: 240 VAC
HP Rating UL 508/IEC60947 [HP (KW)]: 480 VAC
HAC24x150
24-280
600
1
500
150
0.15
1670/1750
13950/12709
1.15
0.15
0.5
2/0 / 67.4
225-300 (25.4-33.9)
10 (7.5)
N/A
HAC60x150
48-660
1200
1
500
150
0.15
1670/1750
13950/12709
1.15
0.15
0.5
2/0 / 67.4
225-300 (25.4-33.9)
N/A
25 (18.75)
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.

HAC60D150
DatasPahneleMeoutnt
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-Off Voltage
Must Turn-Off Voltage
Minimum Input Current (for on-state) [mA]
Maximum Input Current [mA]
Nominal Input Impedance [Ohms]
Maximum Turn-On Time [msec] (4)
Maximum Turn-Off Time [msec]
HACxxD150
4-32 VDC (10)
4 VDC
1 VDC
9
15
Current Regulated
½ Cycle
½ Cycle
HACxxA150
150-270 VAC
150 VAC
10 VAC
6
10
Current Regulated
20
30
GENERAL SPECIFICATIONS (1)
Description
Dielectric Strength, Input/Output (50/60Hz)
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical) lbs/grams
Housing Material
SSR Mounting Torque Range [in lbs/Nm]
LED Input Status Indicator (color)
Humidity
Input Terminal (7)
GENERAL NOTES
(1) All parameters at 25°C unless otherwise specified.
(2) Heat sinking required, see derating curves.
(3) TRM3/0 lug terminal must be used.
(4) Turn-on time for Instantaneous turn-on versions is 0.02 msec.
(5) Instantaneous turn-on version is not recommended for capacitive loads. Use zero turn-on only.
(6) Output will self-trigger (450-600Vpk for HAC24 and 900-1200Vpk for HAC60), not suitable for capacitive loads.
(7) Connector/Plug Not included. See Suggested Mating Connectors/Plugs
(8) Elective Overvoltage Protection, “P” option.
(9) Load can be wired to either SSR output terminal 1 or 2.
(10) Increase minimum voltage by 1V for operations from -20 to -30°C
Parameters
3750 Vrms
2500 Vrms
109 Ohm
10 pF
-30 to 80 °C
-40 to 125 °C
0.75/340.2
PBT 30% GF, UL 94 V-0
18-20 (2-2.2)
YES (Green)
85% non-condensing
Detachable barrier strip
HACxxB150
90-140 VAC
90 VAC
10 VAC
7
12
Current Regulated
20
30
WIRING DIAGRAM
AC
V
L2 ( )
Load
L1 ( )
LOAD SIDE
L2
L1
SOLID STATE CONTACTOR
HAC60D150
INPUT 4-32 VDC
STATUS
Input Current vs Input Voltage
Standard Regulated “DC” Inputs
25
20
15
10
5
0
0 5 10 15 20 25 30
DC Input Voltage
(- / )
(+ / )
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.


Features DatasPahneleMeoutnt HAC Series • Load Voltage range 24 to 660 VAC • Output rating up to 150 Arms • Zero Voltage or Instantaneous Turn-on options • AC or DC input control options • Lockin g Input Connector • Optional Transien t Protection & installed Thermal Pad P RODUCT SELECTION Control Voltage 3-32 V DC 90-140 VAC 150-270 VAC AVAILABLE OPT IONS Series HAC 150 A HAC24D150 ,HAC60 D150 HAC24B150 ,HAC60B150 HAC24A150 ,HA C60A150 Control Voltage A: 150-270 VAC B: 90-140 VAC D: 4-32 VDC Overvoltage Protection Blank: Not Included P: Incl uded (6) Switching Type Blank: Zero Vo ltage Turn-On -10: Instantaneous Turn-O n (5) 24 A 150 P H -10 Operating Volt age 24: 24-280 VAC 60: 48-660 VAC Rate d Load Current 150: 150 Amps Thermal P ad Blank: Not Included H: Included Req uired for valid part number For options only and not required for valid part n umber OUTPUT SPECIFICATIONS (1) Descrip tion Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Volt.
Keywords HAC60D150, datasheet, pdf, Crydom, Panel, Mount, AC60D150, C60D150, 60D150, HAC60D15, HAC60D1, HAC60D, Equivalent, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute




@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)