SBOS681C – JULY 2014 – REVISED NOVEMBER 2017
OPT3001 Ambient Light Sensor (ALS)
1 Features
1 Precision Optical Filtering to Match Human Eye:
– Rejects > 99% (typ) of IR
• Automatic Full-Scale Setting Feature Simplifies
Software and Ensures Proper Configuration
• Measurements: 0.01 lux to 83 k lux
• 23-Bit Effective Dynamic Range With
Automatic Gain Ranging
• 12 Binary-Weighted Full-Scale Range Settings:
< 0.2% (typ) Matching Between Ranges
• Low Operating Current: 1.8 µA (typ)
• Operating Temperature Range: –40°C to +85°C
• Wide Power-Supply Range: 1.6 V to 3.6 V
• 5.5-V Tolerant I/O
• Flexible Interrupt System
• Small-Form Factor: 2.0 mm × 2.0 mm × 0.65 mm
2 Applications
• Display Backlight Controls
• Lighting Control Systems
• Tablet and Notebook Computers
• Thermostats and Home Automation Appliances
• Point-of-Sale Terminals
• Outdoor Traffic and Street Lights
• Cameras
3 Description
The OPT3001 is a sensor that measures the intensity
of visible light. The spectral response of the sensor
tightly matches the photopic response of the human
eye and includes significant infrared rejection.
The OPT3001 is a single-chip lux meter, measuring
the intensity of light as visible by the human eye. The
precision spectral response and strong IR rejection of
the device enables the OPT3001 to accurately meter
the intensity of light as seen by the human eye
regardless of light source. The strong IR rejection
also aids in maintaining high accuracy when industrial
design calls for mounting the sensor under dark glass
for aesthetics. The OPT3001 is designed for systems
that create light-based experiences for humans, and
an ideal preferred replacement for photodiodes,
photoresistors, or other ambient light sensors with
less human eye matching and IR rejection.
Measurements can be made from 0.01 lux up to
83k lux without manually selecting full-scale ranges
by using the built-in, full-scale setting feature. This
capability allows light measurement over a 23-bit
effective dynamic range.
The digital operation is flexible for system integration.
Measurements can be either continuous or single-
shot. The control and interrupt system features
autonomous operation, allowing the processor to
sleep while the sensor searches for appropriate
wake-up events to report via the interrupt pin. The
digital output is reported over an I2C- and SMBus-
compatible, two-wire serial interface.
The low power consumption and low power-supply
voltage capability of the OPT3001 enhance the
battery life of battery-powered systems.
Spectral Response: The OPT3001 and Human Eye
1
OPT3001
0.9 Human Eye
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
300 400 500 600 700 800 900 1000
Wavelength (nm)
D001
Device Information(1)
PART NUMBER
PACKAGE
BODY SIZE (NOM)
OPT3001
USON (6)
2.00 mm x 2.00 mm
(1) For all available packages, see the package option addendum
at the end of the datasheet.
Block Diagram
VDD
Ambient
Light
OPT3001
Optical
Filter
VDD
ADC
I2C
Interface
SCL
SDA
INT
ADDR
GND
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.

OPT3001
OPT3001
SBOS681C – JULY 2014 – REVISED NOVEMBER 2017
www.ti.com
Table of Contents
1 Features .................................................................. 1
2 Applications ........................................................... 1
3 Description ............................................................. 1
4 Revision History..................................................... 2
5 Pin Configuration and Functions ......................... 3
6 Specifications......................................................... 4
6.1 Absolute Maximum Ratings ...................................... 4
6.2 ESD Ratings.............................................................. 4
6.3 Recommended Operating Conditions....................... 4
6.4 Thermal Information .................................................. 4
6.5 Electrical Characteristics........................................... 5
6.6 Timing Requirements ................................................ 6
6.7 Typical Characteristics .............................................. 7
7 Detailed Description ............................................ 10
7.1 Overview ................................................................. 10
7.2 Functional Block Diagram ...................................... 10
7.3 Feature Description................................................. 11
7.4 Device Functional Modes........................................ 13
7.5 Programming........................................................... 16
7.6 Register Maps ......................................................... 19
8 Application and Implementation ........................ 27
8.1 Application Information............................................ 27
8.2 Typical Application .................................................. 28
8.3 Do's and Don'ts ...................................................... 31
9 Power-Supply Recommendations...................... 32
10 Layout................................................................... 33
10.1 Layout Guidelines ................................................. 33
10.2 Layout Example .................................................... 33
11 Device and Documentation Support ................. 34
11.1 Documentation Support ........................................ 34
11.2 Receiving Notification of Documentation Updates 34
11.3 Community Resources.......................................... 34
11.4 Trademarks ........................................................... 34
11.5 Electrostatic Discharge Caution ............................ 34
11.6 Glossary ................................................................ 34
12 Mechanical, Packaging, and Orderable
Information ........................................................... 34
12.1 Soldering and Handling Recommendations.......... 34
12.2 DNP (S-PDSO-N6) Mechanical Drawings ............ 35
4 Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from Revision B (December 2014) to Revision C
Page
• Added Receiving Notification of Documentation Updates and Community Resources ...................................................... 34
Changes from Revision A (October 2014) to Revision B
Page
• Changed Handling Ratings table to ESD Ratings table ......................................................................................................... 4
• Added missing link to Electrical Interface section in Serial Interface section....................................................................... 12
• Added application information to Application and Implementation section .......................................................................... 27
• Added new documents to Related Documentation section ................................................................................................. 34
• Added Soldering and Handling Recommendations section ................................................................................................. 34
Changes from Original (July 2014) to Revision A
Page
• Changed data sheet from product preview to production data .............................................................................................. 1
2 Submit Documentation Feedback
Product Folder Links: OPT3001
Copyright © 2014–2017, Texas Instruments Incorporated


Features Product Folder Order Now Technical Doc uments Tools & Software Support & Com munity OPT3001 SBOS681C – JULY 2014 – REVISED NOVEMBER 2017 OPT3001 Ambie nt Light Sensor (ALS) 1 Features •1 Precision Optical Filtering to Match Hu man Eye: – Rejects > 99% (typ) of IR • Automatic Full-Scale Setting Featur e Simplifies Software and Ensures Prope r Configuration • Measurements: 0.01 lux to 83 k lux • 23-Bit Effective Dy namic Range With Automatic Gain Ranging • 12 Binary-Weighted Full-Scale Rang e Settings: < 0.2% (typ) Matching Betwe en Ranges • Low Operating Current: 1. 8 µA (typ) • Operating Temperature R ange: –40°C to +85°C • Wide Power -Supply Range: 1.6 V to 3.6 V • 5.5-V Tolerant I/O • Flexible Interrupt Sy stem • Small-Form Factor: 2.0 mm × 2 .0 mm × 0.65 mm 2 Applications • Dis play Backlight Controls • Lighting Co ntrol Systems • Tablet and Notebook C omputers • Thermostats and Home Autom ation Appliances • Point-of-Sale Terminals • Outdoor Traffic and Street Lights • Cameras 3 Description Th.
Keywords OPT3001, datasheet, pdf, etcTI, Ambient, Light, Sensor, PT3001, T3001, 3001, OPT300, OPT30, OPT3, Equivalent, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute




@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)