STPM32, STPM33, STPM34
Datasheet
ASSP for metering applications with up to four independent 24-bit 2nd order sigma-delta...
STPM32, STPM33, STPM34
Datasheet
ASSP for metering applications with up to four independent 24-bit 2nd order sigma-delta ADCs, 4 MHz OSF and 2 embedded PGLNA
Product status link STPM32 STPM33 STPM34
Product label
Features
Active power accuracy:
– < 0.1% error over 5000 : 1 dynamic range
– < 0.5% error over 10000 : 1 dynamic range
Exceeds 50-60 Hz EN 50470-x, IEC 62053-2x, ANSI12.2x standard requirements for AC watt meters
Reactive power accuracy:
– < 0.1% error over 2000 : 1 dynamic range
Dual mode apparent energy calculation
Instantaneous and averaged power
RMS and instantaneous voltage and current
Under and overvoltage detection (sag and swell) and monitoring
Overcurrent detection and monitoring
UART and SPI serial interface with programmable CRC polynomial verification
Programmable LED and interrupt outputs
Four independent 24-bit 2nd order sigma-delta ADCs
Two programmable gain chopper stabilized low-noise and low-offset amplifiers
Bandwidth 3.6 kHz at -3 dB
Vcc supply range 3.3 V ± 10%
Supply current Icc 4.3 mA (STPM32)
Input clock frequency 16 MHz, Xtal or external source
Twin precision voltage reference: 1.18 V with independent programmable TC, 30 ppm/°C typ.
Internal low drop
regulator at 3 V (typ.)
QFN packages
Operating temperature from -40 °C to +105 °C
Description
The STPM3x is an ASSP family designed for high accuracy measurement of power and energies in power line systems using the Rogowski coil...