DatasheetsPDF.com

JTL4024S05 Dataheets PDF



Part Number JTL4024S05
Manufacturers XP Power
Logo XP Power
Description DC-DC Converter
Datasheet JTL4024S05 DatasheetJTL4024S05 Datasheet (PDF)

DC DC 40 Watts JTL Series xppower.com • 4:1 Input Range • High Power Density • Single and Dual Outputs • High Efficiency Up to 92% • Remote On/Off • 1600 VDC Isolation • 3 Year Warranty Specification Input Input Voltage Range Input Current Input Reflected Ripple Current Input Reverse Voltage Protection Undervoltage Lockout Input Filter Input Surge • 24 V (9-36 VDC), 48 V (18-75 VDC) • See table • 20 mA pk-pk through 12 µH inductor • None • 24 V models: ON 8.6 V, OFF 7.9 V typical 48 V mode.

  JTL4024S05   JTL4024S05


Document
DC DC 40 Watts JTL Series xppower.com • 4:1 Input Range • High Power Density • Single and Dual Outputs • High Efficiency Up to 92% • Remote On/Off • 1600 VDC Isolation • 3 Year Warranty Specification Input Input Voltage Range Input Current Input Reflected Ripple Current Input Reverse Voltage Protection Undervoltage Lockout Input Filter Input Surge • 24 V (9-36 VDC), 48 V (18-75 VDC) • See table • 20 mA pk-pk through 12 µH inductor • None • 24 V models: ON 8.6 V, OFF 7.9 V typical 48 V models: ON 17.8 V, OFF 16 V typical • Pi network • 24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms Output Output Voltage • See table Output Voltage Trim • ±10% Minimum Load • No minimum load required Line Regulation • ±0.5% max Load Regulation • Single output models: ±0.5% max Dual output models: ±1% max balanced outputs Cross Regulation • ±5% for dual outputs (see note 2) Setpoint Accuracy • ±1% Start Up Time • 25 ms typical Ripple & Noise • 50 mV pk-pk max for 3.3 V & 5 V models, 75 mV pk-pk max for other single output models, 150 mV pk-pk max for dual output models, 20 MHz bandwidth, (see note 3) Transient Response • 3% max deviation, recovery to within 1% in <250 µs for a 25% load change Temperature Coefficient • 0.02%/°C Overvoltage Protection • 3.3 V models: 3.9 V typical 5 V models: 6.2 V typical 12 V models: 15 V typical 15 V models: 18 V typical ±12 V models: ±15 V typical ±15 V models: ±18 V typical Overload Protection • >130% of full load Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery Remote On/Off • On = Logic High (>3.0) or Open Off = Logic Low (<1.2 V) or short pin 2 to 3 Max Capacitive Load • See table General Efficiency Isolation Isolation Capacitance Switching Frequency Power Density MTBF • See table • 1600 VDC Input to Output 1600 VDC Input to Case 1600 VDC Output to Case • 2500 pF max • 270 kHz, typical • 25 W/in3 • 150 kHrs min to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • -40 °C to +85 °C, see derating curve Case Temperature • +105 °C max Cooling • Convection-cooled Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 °C to +125 °C EMC & Safety Emissions ESD Immunity EFT/Burst Surge Conducted Immunity Magnetic Fields • EN55022, class A conducted and radiated with external components • EN61000-4-2, level 3, Perf Criteria A • EN61000-4-4, level 3, Perf Criteria A (see note 4) • EN61000-4-5, installation class 2, Perf Criteria A (see note 4) • EN61000-4-6, 3 Vrms, Perf Criteria A • EN61000-4-8, 1 A/m, Perf Criteria A DC DC Models and Ratings JTL40 Input Voltage 9-36 VDC 18-75 VDC Output Voltage 3.3 V 5.0 V 12.0 V 15.0 V ±12.0 V ±15.0 V 3.3 V 5.0 V 12.0 V 15.0 V ±12.0 V ±15.0 V Output Current 10.00 A 8.00 A 3.35 A 2.65 A ±1.65 A ±1.35 A 10.00 A 8.00 A 3.35 A 2.65 A ±1.65 A ±1.35 A Input Current (1) No Load Full Load 80 mA 1600 mA 100 mA 1900 mA 50 mA 1930 mA 50 mA 1910 mA 60 mA 1920 mA 60 mA 1960 mA 60 mA 800 mA 60 mA 940 mA 30 mA 970 mA 30 mA 940 mA 30 mA 950 mA 30 mA 970 mA Maximum Capacitive Load 25000 µF 13000 µF 2300 µF 1500 µF ±1200 µF ±750 µF 25000 µF 13000 µF 2300 µF 1500 µF ±1200 µF ±750 µF Efficiency 89% 91% 90% 90% 89% 89% 89% 92% 90% 91% 90% 90% Model Number JTL4024S3V3 JTL4024S05 JTL4024S12 JTL4024S15 JTL4024D12 JTL4024D15 JTL4048S3V3 JTL4048S05 JTL4048S12 JTL4048S15 JTL4048D12 JTL4048D15 Notes 1. Input current specified at nominal 24 V or 48 V input. 2. Cross regulation for duals is ±5% when one output is at 100% and the other is varied between 25% and 100%. 3. Measured with 1 µF ceramic capacitor across output rails. 4. A 220 µF/250 V capacitor across the input is required in order to meet EN61000-4-4 and EN61000-4-5. 5. Efficiency is measured at full load and nominal input at 25 °C. 6. For heatsink option, add ‘-HK’ to the end of the part number. Mechanical Details 0.20 (5.0) 0.30 (7.6) 0.20 0.30 0.20 (5.0) (7.6) (5.0) 4 56 78 Dia. 0.04 (1.0) 0.40 (10.2) 2.00 (50.8) 1.80 (45.7) Bottom View Optional heatsink (-HK) 0.64 (16.3) 2.00 (50.80) 12 3 0.20 (5.0) 2.00 (50.8) 0.40 (10.1) 1.10 (27.9) 0.20 (5.0) min. Thermal Pad PIN CONNECTIONS Pin Single Dual 1 +Vin +Vin 2 -Vin -Vin 3 Remote On/Off Remote On/Off 4 -Sense +Vout 5 +Sense Com 6 +Vout Com 7 -Vout -Vout 8 Trim Trim Notes 1. All dimensions are in inches (mm). 2. Weight: 0.07 lbs (30 g) approx 3. Pin diameter: 0.04 ±0.002 (1.0 ±0.05) 4. Pin pitch tolerance: ±0.014 (±0.35) 5. Case tolerance: ±0.02 (±0.5) Application Notes Derating Curve Output Power 100% 75% 50% 25% without heat-sink with heat-sink -40 -20 0 20 40 55 60 64 80 85 100 Ambient Temperature (ºC) External Output Trim 7 (7) R trim-up 8 (8) 8 (8) R trim-down 6 (4) Output can be externally trimmed using this method. ( ) for dual output t.


JTL4024S3V3 JTL4024S05 JTL4024S12


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)