Part Number RHV3-1205D-R20
Manufacturers RECOM
Logo RECOM
Description DC/DC Converter
Datasheet RHV3-1205D-R20 DatasheetRHV3-1205D-R20 Datasheet (PDF)

Features Unregulated Converters • 12.5kVAC/1 minute isolation • Compact SIP16 case with >30mm pin separation • • bLuolwlet4poFinmtsax(P. irsoodluactitomnacnaapgaecri)tance • Wide operating temperature range from -40°C to +80°C at full load • Efficiency up to 81% DC/DC Converter RHV3 Description The RHV3 is a DC/DC converter with exceptionally high 20kVDC (12.5KVAC/1 minute) isolation in a compact SIP16 case. Input voltages can be 5, 12 or 24VDC and outputs 5V, 12V, 24V, ±5V or ±12V. .

  RHV3-1205D-R20   RHV3-1205D-R20


Document
Features Unregulated Converters • 12.5kVAC/1 minute isolation • Compact SIP16 case with >30mm pin separation • • bLuolwlet4poFinmtsax(P. irsoodluactitomnacnaapgaecri)tance • Wide operating temperature range from -40°C to +80°C at full load • Efficiency up to 81% DC/DC Converter RHV3 Description The RHV3 is a DC/DC converter with exceptionally high 20kVDC (12.5KVAC/1 minute) isolation in a compact SIP16 case. Input voltages can be 5, 12 or 24VDC and outputs 5V, 12V, 24V, ±5V or ±12V. The operating temperature is -40°C to +80°C without derating. Applications include high vacuum monitoring, X-Ray equipment, HVAC dust extraction systems and other high voltage industrial applications where a very high isolation remote power supply is required. 3 Watt SIP16 Single and Dual Output Selection Guide Part Number nom. Input Output Output Efficiency max. Capacitive Voltage Voltage Current typ. (1) Load (2) [VDC] [VDC] [mA] [%] [µF] RHV3-0505S/R20 5 5 600 76 1000 RHV3-0512S/R20 5 12 250 78 330 RHV3-0524S/R20 5 24 125 80 100 RHV3-1205S/R20 12 5 600 78 1000 RHV3-1212S/R20 12 12 250 79 330 RHV3-1224S/R20 12 24 125 80 100 RHV3-2405S/R20 24 5 600 80 1000 RHV3-2412S/R20 24 12 250 80 330 RHV3-2424S/R20 24 24 125 81 100 RHV3-0505D/R20 5 ±5 ±300 78 ±680 RHV3-0512D/R20 5 ±12 ±125 80 ±150 RHV3-1205D/R20 12 ±5 ±300 78 ±680 RHV3-1212D/R20 12 ±12 ±125 81 ±150 RHV3-2405D/R20 24 ±5 ±300 80 ±680 RHV3-2412D/R20 24 ±12 ±125 80 ±150 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: The capacitive load is tested at minimum input and constant resistive load IEC/EN62368-1 certified IEC/EN61010-1 certified Model Numbering RHV3-__ __ Output Power nom. Input Voltage Output Voltage /R20 Isolation Voltage Single or Dual Output www.recom-power.com REV.: 0/2019 ECO-1 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Internal Input Filter Input Voltage Range Minimum Load Internal Operating Frequency Output Ripple and Noise (3) Condition 20MHz BW Min. 0% 20kHz Notes: Note3: Measurements are made with a 0.1µF MLCC across output (low ESR) RHV3 Series Typ. ±10% Max. capacitors 45kHz 150mVp-p 200mVp-p Efficiency [%] Efficiency vs. Load RHV3-0505S/R20 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] Efficiency [%] RHV3-2424S/R20 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 Output Load [%] 90 100 Efficiency [%] RHV3-0505D/R20 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] Efficiency [%] RHV3-1205S/R20 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] www.recom-power.com REV.: 0/2019 ECO-2 RHV3 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Series REGULATIONS Parameter Output Accuracy Line Regulation Load Regulation (4) Cross Regulation Tolerance Envelope Condition low line to high line, full load 10% to 100% load 5Vin others 10% to 100% load Notes: Note4: Operation below 10% load will not harm the converter, but specifications may not be met Value ±5.0% max. ±1.2% of 1.0% Vin typ. 15.0% max. 10.0% max. ±7.5% typ. RHV3-0505S/R20 RHV3-0524S/R20 +15% +12.5% Vnom Typical Load Line +5% +0.5% -5% +10% +8% Vnom Typical Load Line +5% -1.5% -5% Output Voltage [%] Output Voltage [%] 10 +15% +12% Vnom 50 Output Load [%] RHV3-0505D/R20 100 Typical Load Line +5% +1.5% -5% 10 50 100 Output Load [%] RHV3-2412D/R20 +10% +6.6% Vnom Typical Load Line +5% -1.5% -5% Output Voltage [%] Output Voltage [%] 10 +15% +10% Vnom 50 Output Load [%] RHV3-1205S/R20 100 Typical Load Line +5% +1% -5% 10 50 100 Output Load [%] RHV3-2424S/R20 +10% +6.5% Vnom Typical Load Line +5% 0% -5% Output Voltage [%] Output Voltage [%] 10 www.recom-power.com 50 Output Load [%] 100 REV.: 0/2019 10 50 100 Output Load [%] ECO-3 RHV3 DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Series PROTECTIONS Parameter Isolation Voltage (5) I/P to O/P Type tested for 1 second tested for 1 minute Value 20kVDC 12.5kVAC Isolation Resistance Isolation Capacitance 15GW min. 3.5pF typ./ 4pF max. Insulation Grade reinforced Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note6: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type ENVIRONMENTAL Parameter Operating Temperature Range Maximum Case Temperature Temperature Coefficient Thermal Impedance Operating Altitude Operating Humidity Pollution Degree Vibration MTBF Derating Graph (@ Chamber and natural convection 0.1m/s) Condition w.


RHV3-0512D-R20 RHV3-1205D-R20 RHV3-1212D-R20


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)