G5CE-1-TP Relay Datasheet

G5CE-1-TP Datasheet, PDF, Equivalent


Part Number

G5CE-1-TP

Description

Power PCB Relay

Manufacture

Omron

Total Page 4 Pages
Datasheet
Download G5CE-1-TP Datasheet


G5CE-1-TP
PCB Relay
Flat Relays that Switch 10-A/15-A Loads
with New Quick-connect Terminals
I Ideal for switching power in household appliances
or for outputs from industrial devices.
I Subminiature dimensions: 22 ™ 16 ™ 11 mm
(L ™ W ™ H).
I High-sensitivity models available with low power
consumption (150 mW).
I UL and CSA approved.
I Fully sealed models and quick-connect terminal
models available (#187 load contact terminals).
G5C(E)
4+-
Ordering Information
Contact form Enclosure ratings General purpose
High-sensitivity
High-capacity
SPST-NO
Flux protection
Fully sealed
G5C-1
G5C-14
G5C-1-H
G5C-14-H
G5CE-1
---
Note: 1. When ordering, add the rated coil voltage to the model number.
Example: G5C-1 12 VDC
Rated coil voltage
2. High-capacity models with a Fully sealed structure are not available.
3. Standard or high-sensitivity models with quick-connect terminals are not available.
4. VDE-approved models are available. Contact your OMRON representative for more details.
5. Models with PTI250 are also available.
Contact your OMRON representative for more details.
Model Number Legend
G5C -
-
1 23 4
1. Relay
None: Standard
E: High-capacity
VDC
5
2. Number of Poles
4. Classification
1: 1 pole (SPST-NO) H: High-sensitivity
3. Enclosure Ratings
TP: Quick-connect terminals (#187)
None: Flux protection 5. Rated Coil Voltage
4: Fully sealed
3, 5, 6, 12, 24, 48 VDC
Quick-connect
terminals
G5CE-1-TP
---
128

G5CE-1-TP
G5C(E)
G5C(E)
Specifications
I Coil Ratings
Item
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Standard, high-capacity, or quick-connect
terminals
5 VDC
12 VDC
24 VDC
40 mA
16.7 mA
8.3 mA
125 W
720 W
2,880 W
75% max. of rated voltage
10% min. of rated voltage
150% (standard)/130% (high-capacity, quick-con-
nect terminals) of rated voltage (at 23•C)
Approx. 200 mW
I Contact Ratings
High-sensitivity
5 VDC
12 VDC
30 mA
12.5 mA
167 W
960 W
80% max. of rated voltage
24 VDC
6.25 mA
3,840 W
150% (at 23•C)
Approx. 150 mW
Item
Rated load
Rated carry current
Max. switching
voltage
Max. switching
current
Max. switching
power
Standard
Resistive load
(cosf = 1)
10 A at 250 VAC;
10 A at 30 VDC
10 A
250 VAC
Inductive load
(cosf = 0.4,
L/R = 7 ms)
3 A at 250 VAC;
3 A at 30 VDC
10 A
2,500 VA, 300 W 750 VA, 90 W
High-sensitivity
Resistive load
(cosf = 1)
10 A at 250 VAC;
10 A at 30 VDC
10 A
250 VAC
Inductive load
(cosf = 0.4,
L/R = 7 ms)
3 A at 250 VAC;
3 A at 30 VDC
10 A
2,500 VA, 300 W 750 VA, 90 W
High-capacity, or quick-connect
terminals
Resistive load
(cosf = 1)
Inductive load
(cosf = 0.4,
L/R = 7 ms)
15 A at 110 VAC; 5 A at 110 VAC;
10 A at 30 VDC 3 A at 30 VDC
15 A
250 VAC
15 A
2,500 VA, 300 W 750 VA, 90 W
I Characteristics
Contact resistance
Operate time
Release time
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
30 mW max. (Quick-connect terminals type: 100 mW max.)
10 ms max. (High-sensitivity type: 15 ms max.)
10 ms max.
1,000 MW min.
2,500 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
4,500 V (1.2 x 50 µs) between coil and contacts
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s2
Malfunction: 200 m/s2
Mechanical: 20,000,000 operations min. at 18,000 operations/hr
Electrical: 300,000 operations min. (100,000 operations min. for Fully sealed Type)
at 1,200 operations/hr under rated load of 10 A at 250 VAC;
100,000 operations min. under load of 15 A at 110 VAC for high-capacity models
100,000 operations min. at 1,200 operations/hr under rated load of 10 A at 30 VDC
Operating: -25°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 8 g (for TP model: Approx. 9.6 g)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
I Approved Standards
UL508 (file No. E41515)/CSA C22.2 No.14 (file No. LR31928)
3 to 100 VDC
Coil rating
Contact rating
15 A, 125 VAC
10 A, 250 VAC
10 A, 30 VDC (resistive load only)
129


Features PCB Relay Flat Relays that Switch 10-A/1 5-A Loads with New Quick-connect Termin als I Ideal for switching power in hous ehold appliances or for outputs from in dustrial devices. I Subminiature dimens ions: 22 ™ 16 ™ 11 mm (L ™ W ™ H). I High-sensitivity models available wit h low power consumption (150 mW). I UL and CSA approved. I Fully sealed models and quick-connect terminal models avai lable (#187 load contact terminals). G 5C(E) 4+- Ordering Information Contac t form Enclosure ratings General purpos e High-sensitivity High-capacity SPS T-NO Flux protection Fully sealed G5C -1 G5C-14 G5C-1-H G5C-14-H G5CE-1 --- Note: 1. When ordering, add the rated coil voltage to the model number. Exam ple: G5C-1 12 VDC Rated coil voltage 2. High-capacity models with a Fully seal ed structure are not available. 3. Stan dard or high-sensitivity models with qu ick-connect terminals are not available . 4. VDE-approved models are available. Contact your OMRON representative for more details. 5. Models with.
Keywords G5CE-1-TP, datasheet, pdf, Omron, Power, PCB, Relay, 5CE-1-TP, CE-1-TP, E-1-TP, G5CE-1-T, G5CE-1-, G5CE-1, Equivalent, stock, pinout, distributor, price, schematic, inventory, databook, Electronic, Components, Parameters, parts, cross reference, chip, Semiconductor, circuit, Electric, manual, substitute




@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)