DC/DC Converter. TSR0.6-4833WI Datasheet

TSR0.6-4833WI Converter. Datasheet pdf. Equivalent


TRACO POWER TSR0.6-4833WI
Non-Isolated DC/DC Converter (POL)
TSR 0.6WI Series, 0.6 A
Ultra wide 8:1 input voltage range:
9-72 VDC
Covers a majority of standard bus- and
battery voltages
Up to 94% efficiency - No heatsink
required
Pin compatible with LMxx linear
regulators (SIP-3)
Operating temperature range
-40 to +85°C
Low standby current
Excellent line/load regulation
Protection against short circuit,
overvoltage and overtemperature
3-year product warranty
The TSR 0.6WI is a non-isolated POL converter series with an ultra wide 8:1 in-
put voltage range which comes in a standard SIP-3 package. Covering the ma-
jority of standard bus- and battery voltages this POL converter is a versatile so-
lution for many applications in distributed power systems where different input
voltages have to be handled. Being able to use the same converter in many dif-
ferent situations effectively reduces the bill of material (BOM) of a given appli-
cation. A high efficiency of up to 94% allows for an operating temperature
range of -40 to +85°C (up to 80°C without derating) and makes them excellent
drop-in replacements for less efficient LMxx linear regulators. With 0.6A max.
output current and standard features such as low standby current, precise reg-
ulation and protection against short circuit, overvoltage and overload the TSR
0.6WI is suitable for many battery and distributed power applications.
Models
Order Code
TSR 0.6-4833WI
TSR 0.6-4850WI
TSR 0.6-4865WI
TSR 0.6-4890WI
TSR 0.6-48120WI
TSR 0.6-48150WI
TSR 0.6-48240WI
Output Current
max.
600 mA
400 mA
Input Voltage
Range
9 - 72 VDC (48 VDC nom.)
14 - 72 VDC (48 VDC nom.)
17 - 72 VDC (48 VDC nom.)
20 - 72 VDC (48 VDC nom.)
33 - 72 VDC (48 VDC nom.)
Output Voltage
nom.
3.3 VDC
5 VDC
6.5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
Efficiency
typ.
85 % (at 24 Vin)
89 % (at 24 Vin)
91 % (at 24 Vin)
92 % (at 24 Vin)
93 % (at 24 Vin)
94 % (at 24 Vin)
94 % (at 48 Vin)
Options
on demand
(backorder with MOQ - Horizontal mounting (see outline dimensions)
non stocking item)
Note - It is recommended to use an external input filter, please refer to application note: www.tracopower.com/overview/tsr0.6wi
www.tracopower.com
February 13, 2020
Page 1 / 4


TSR0.6-4833WI Datasheet
Recommendation TSR0.6-4833WI Datasheet
Part TSR0.6-4833WI
Description Non-Isolated DC/DC Converter
Feature TSR0.6-4833WI; Non-Isolated DC/DC Converter (POL) TSR 0.6WI Series, 0.6 A • Ultra wide 8:1 input voltage range: 9.
Manufacture TRACO POWER
Datasheet
Download TSR0.6-4833WI Datasheet




TRACO POWER TSR0.6-4833WI
TSR 0.6WI Series
Input Specifications
Input Current
- At no load
Recommended Input Fuse
Input Filter
3 mA typ.
3.3 Vout models: 800 mA (slow blow)
5 Vout models: 800 mA (slow blow)
6.5 Vout models: 1'000 mA (slow blow)
9 Vout models: 1'000 mA (slow blow)
12 Vout models: 1'000 mA (slow blow)
15 Vout models: 1'000 mA (slow blow)
24 Vout models: 800 mA (slow blow)
See application note: www.tracopower.com/overview/tsr0-6wi
(Recommended external input filter proposal)
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (10 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
Capacitive Load
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Transient Response
- Peak Variation
- Response Time
±2.5% max.
0.9% max.
0.6% max.
3.3 Vout models: 50 mVp-p typ.
5 Vout models: 50 mVp-p typ.
6.5 Vout models: 50 mVp-p typ.
9 Vout models: 50 mVp-p typ.
12 Vout models: 50 mVp-p typ.
15 Vout models: 50 mVp-p typ.
24 Vout models: 75 mVp-p typ.
100 µF max.
Not required
±0.02 %/K max.
50 ms typ. (24 Vout model)
25 ms typ. (other models))
Continuous, Automatic recovery
200% typ. of Iout max.
90 mV typ. / 180 mV max. (50% Load Step)
200 µs typ. / 250 µs max. (50% Load Step)
General Specifications
Relative Humidity
Temperature Ranges
- Operating Temperature
- Case Temperature
- Storage Temperature
Power Derating
- High Temperature
Over Temperature
Protection Switch Off
- Protection Mode
- Measurement Point
Cooling System
Switching Frequency
Insulation System
Reliability
Environment
Housing Material
- Calculated MTBF
- Vibration
- Mechanical Shock
- Thermal Shock
95% max. (non condensing)
–40°C to +85°C
+105°C max.
–55°C to +125°C
3.57 %/K above 77°C
165°C typ. (Automatic recovery)
Internal IC temperature
Natural convection (20 LFM)
117 - 243 kHz (PWM) (3.3 Vout model)
130 - 270 kHz (PWM) (5 Vout model)
163 - 338 kHz (PWM) (6.5 Vout model)
195 - 405 kHz (PWM) (9 Vout model)
247 - 513 kHz (PWM) (12 Vout model)
293 - 608 kHz (PWM) (15 Vout model)
416 - 864 kHz (PWM) (24 Vout model)
Non-isolated
18'160'000 h (MIL-HDBK-217F, ground benign)
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
Non-conductive Plastic
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
February 13, 2020
Page 2 / 4



TRACO POWER TSR0.6-4833WI
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Connection Type
Weight
Environmental Compliance - Reach
- RoHS
Supporting Documents
Overview Link (for additional Documents)
Outline Dimensions
Standard: Vertical mounting
12.0 (0.47)
123
2 x 2.54 (2 x 0.100)
0.5 (0.02)
3.5 (0.14)
TSR 0.6WI Series
Epoxy (UL 94 V-0 rated)
Brass
Nickel (1 - 2 µm)
Tin (3 - 5 µm), matte
THD (Through-Hole Device)
3g
www.tracopower.com/info/reach-declaration.pdf
www.tracopower.com/info/rohs-declaration.pdf
www.tracopower.com/overview/tsr0-6wi
Pinout
Pin Function
1 +Vin
2 GND
3 +Vout
Bottom View
0.50 x 0.25 (0.02 x 0.01)
Dimensions in mm (inch)
Tolerances: x.xx ±0.5 (±0.02)
Tolerances: x.xxx ±0.25 (±0.01)
Pin dimension tolerances: ±0.10 (±0.04)
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
February 13, 2020
Page 3 / 4







@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site (Privacy Policy & Contact)