Document
G8P
PCB Power Relay
Up to 30 A switching capacity in compact package. 2.0 mm cantact gap type available (G8P-1A4P-BG)
• Available with quick-connect contact terminals for easy load connecting with either QC or PCB coil terminals.
• UL Class F coil insulation standard. • Minimum 6 kV Impulse Surge Withstand. • Standard model conforms to UL/CSA standards. • VDE approved. • NEW G8P-1A4P-BG (Special type)
2.0 mm contact gap, high dielectric strength 4,000VAC.
RoHS Compliant
RC
■Model Number Legend
G8P- @— @— @— @— - @— -@—
1234 5 6
1. Number of poles 1: 1-pole
2. Contact Form A: SPST-NO (1a) C: SPDT (1c)
3. Enclosure rating
5. Mounting
None: Open frame
None: PCB mounting
2: Unsealed (Vented)
F: Flanged mounting
4: Fully sealed (Sealed with ventable nib)
6. Special
4. Terminal Shape
BG: 2.0 mm contact gap
P: PCB terminals
T: Quick-connect terminals
(#250 terminals for contacts and #187
terminals for coil)
TP: PCB & Quick-connect terminals (#250 terminals) and straight PCB for
contacts, and straight PCB for coil
G 8 P
■Application Examples
• Ideal for home and industrial appliances • HVAC (heating, ventilating, and air conditioning) • Solar Inverter • Many other applications
■Ordering Information
Classification
Standard
Relay Function
Single-side Stable
Terminal Shape
PCB terminals
PCB & Quick connect terminals
Quick-contact terminals
Contact form
SPST-NO (1a)
SPDT (1c) SPST-NO (1a) SPDT (1c) SPST-NO (1a) SPDT (1c)
Enclosure rating
Open frame
Sealed with ventable nib
Open frame Sealed with ventable nib Open frame Sealed with ventable nib Open frame Sealed with ventable nib Vented Vented
Model
G8P-1AP G8P-1A4P-BG G8P-1A4P G8P-1CP G8P-1C4P G8P-1ATP G8P-1A4TP G8P-1CTP G8P-1C4TP G8P-1A2T-F G8P-1C2T-F
Rated coil voltage
5VDC 9VDC 12VDC 24VDC 48VDC 110VDC
(-BG: 12VDC, 24VDC)
Minimum packing unit
50 pcs/tray
Note: When ordering, add the rated coil voltage to the model number.
Example: G8P-1AP 12 VDC Rated coil voltage
1
■Ratings ● Coil
Rated voltage (VDC)
5 9 12 24 48 110
Rated current (mA)
185 93 77 36 19 9
Coil Must operate voltage
resistance
(V)
(Ω)
27 97 155 660 2,480 12,400
75% max.
Must release voltage (V)
% of rated voltage
10% min.
Max. voltage (V)
120% max.
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Power consumption
(mW)
Approx. 900
● Contact
Load
Contact Type Contact material
Rated load
G 8
Rated carry current
P Max. switching voltage
Max. switching current
Note: NO contact/NC contact
SPST-NO (1a)
Single
Ag-alloy (Cd free)
30A at 250VAC (-BG: 20A at 250VAC)
20A at 28VDC (-BG: ----
)
30A (-BG: 20A)
250VAC 28VDC (-BG: 250VAC)
AC30A DC20A (-BG: AC20A)
Resistive load
SPDT (1c)
20A/10A (See note.) at 250VAC 20A/10A (See note.) at 28VDC 20A/10A (See note.).