FEATURES
1
2 Input Voltage Range: 10 V to 80 V
Real-Time Monitoring of VIN, IIN, PIN, VOUT, and VAUX with 12-bit resolution, 1-kHz sampling rate
True input Power Measurement using simultaneous sampling of Vin and Iin
Remote Temperature Sensing with programmable warning thresholds
Power Measurement Accuracy
– LM5056A: ±1.75%
– LM5056: ±2.25%
Current Measurement Accuracy
– LM5056A: ±1.25%
– LM5056: ±1.5%
Voltage Measurement Accuracy: ±1.0%
Averaging of VIN, IIN, PIN, and VOUT with Programmable Interval Ranging from 0.001 s to 4 s
Programmable WARN and FAULT Thresholds with SMBA Notification
Black-Box Capture of Telemetry Measurements and Device Status Triggered by WARN or FAULT Condition
I2C/SMBus Interface and PMBus Compliant Command Structure
APPLICATIONS
Server Backplane Systems
Base Station Power Distribution Systems
Industrial Telemetry Applications
DESCRIPTION
The LM5056/LM5056A combines high-performance analog and digital technology with a PMBus™ compliant SMBus™ and I2C interface to accurately measure the electrical operating conditions of systems connected to a backplane power bus. The LM5056/LM5056A continuously supplies real-time power, voltage, current, temperature and fault data to the system management host via the SMBus interface.
The LM5056/LM5056A monitoring block compu...