Negative Hot Swap / Inrush Current Controller
LM5067
www.ti.com
SNVS532C – OCTOBER 2007 – REVISED MARCH 2013
Negative Hot Swap / Inrush Current Controller with Pow...
Description
LM5067
www.ti.com
SNVS532C – OCTOBER 2007 – REVISED MARCH 2013
Negative Hot Swap / Inrush Current Controller with Power Limiting
Check for Samples: LM5067
FEATURES
1
2 Wide operating range: -9V to -80V In-rush current limit for safe board insertion
into live power sources Programmable maximum power dissipation in
the external pass device Adjustable current limit Circuit breaker function for severe over-
current events Adjustable under-voltage lockout (UVLO) and
hysteresis Adjustable over-voltage lockout (OVLO) and
hysteresis Initial insertion timer allows ringing and
transients to subside after system connection Programmable fault timer avoids nuisance
trips Active high open drain POWER GOOD output Available in latched fault and automatic restart
versions
PACKAGES
VSSOP-10 SOIC-14 (Latched Fault Version)
DESCRIPTION
The LM5067 negative hot swap controller provides intelligent control of the power supply connections during insertion and removal of circuit cards from a live system backplane or other “hot” power sources. The LM5067 provides in-rush current control to limit system voltage droop and transients. The current limit and power dissipation in the external series pass NChannel MOSFET are programmable, ensuring operation within the Safe Operating Area (SOA). In addition, the LM5067 provides circuit protection by monitoring for over-current and over-voltage conditions. The POWER GOOD output indicates when the output voltage is close to the inp...